High Risk Work Licence - Non-Slewing Mobile Crane CN flashcards
High Risk Work Licence - Non-Slewing Mobile Crane CN · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CN Licence Scope
- The CN high risk work licence authorises operation of non-slewing mobile cranes with a rated capacity greater than 3 tonnes. It does not cover slewing mobile cranes.
- Duty of Care
- A legal obligation on employers and workers to ensure health and safety so far as reasonably practicable, including providing information, training, and supervision.
- Safe Work Method Statement
- A document describing high risk construction work, the hazards, and the control measures. Work must be carried out in accordance with it.
- Notifiable Incident
- A death, serious injury, or dangerous incident that must be reported to the regulator immediately, with the site preserved until inspection.
- Hierarchy of Control
- A ranked order of risk controls: eliminate, substitute, engineering controls, administrative controls, then personal protective equipment as the last resort.
- Exclusion Zone
- An area around the crane and its load path where unauthorised persons are not permitted, set from the full working envelope.
- Risk Score
- The product of likelihood and consequence used to rank hazards and determine whether controls reduce risk to as low as reasonably practicable.
- Stop-Work Condition
- A situation where a hazard cannot be controlled within the lift plan or crane limits, requiring work to cease until the plan is revised.
- Rated Capacity
- The maximum load a crane may lift in a specific configuration, as stated in the manufacturer's load chart for that radius and boom length.
- Working Radius
- The horizontal distance from the crane's centre of rotation or boom pivot to the centre of gravity of the suspended load.
- Gross Load
- The total of the load, slings, rigging, hook block, and attachments. All of it counts against the rated capacity.
- Pick-and-Carry Capacity
- The reduced capacity for travelling with a suspended load, usually lower than static capacity and governed by a separate chart.
- Pre-Start Inspection
- A daily check of the crane before use, covering logbook, tyres, brakes, hydraulics, wire rope, hook, and safety devices.
- Ground Bearing Pressure
- The pressure imposed by the crane and load through each outrigger pad. The ground capacity must exceed it to prevent settlement or tipping.
- Outrigger Setup
- Fully extending and pinning outriggers on load-spreading pads on stable ground, with the crane level, before any lift.
- Wire Rope Discard
- Removal from service when broken wires, kinks, corrosion, or diameter reduction exceed the manufacturer's stated limits.
- Working Load Limit
- The maximum load a sling or lifting fitting may carry in a stated configuration; it must never be exceeded.
- Sling Tension Formula
- Tension per leg equals load divided by the number of legs multiplied by the sine of the angle from horizontal.
- Centre of Gravity
- The point where the load's weight is concentrated. An off-centre lift causes rotation and unequal loading on sling legs.
- Load Estimation
- Calculating load weight from volume multiplied by material density, for example steel at about 7850 kilograms per cubic metre.
- Designated Signal Person
- The single person appointed to direct the operator. All other persons relay signals through this person except emergency stop.
- Emergency Stop Signal
- A signal that any person may give. The operator must stop immediately regardless of who gives it.
- Line of Sight Rule
- The signal person must remain visible to the operator. If sight is lost, the lift stops until communication is restored.
- Pre-Lift Briefing
- A team meeting covering load weight, path, radius, signals, exclusion zones, and emergency arrangements before the lift begins.
- Shock Loading
- A sudden force from jerking or dropping a load, which can exceed the rated capacity. Avoid it by starting and stopping smoothly.
- Travel with Load
- Moving the crane while carrying a load, permitted only when the manufacturer allows it, with the load kept low and controlled.
- Wind Limit
- The maximum wind speed set by the manufacturer for safe lifting. Lifting stops when the load becomes uncontrollable.
- Powerline Contact
- If the crane contacts live lines, the operator stays in the cab and warns others away; if evacuation is required, jump clear and shuffle away.
- Suspended Load Emergency
- If a load cannot be lowered, establish an exclusion zone and seek competent assistance. Never leave a suspended load unattended.
- Shutdown Procedure
- Lower attachments, apply the parking brake, chock the wheels, isolate the battery, and secure the machine at the end of the shift.
- Defect Classification
- Defects are minor or major. A major defect requires the crane to be taken out of service immediately until rectified.
- Major Inspection
- A thorough inspection by a competent person after significant repair, alteration, or an incident affecting structural integrity, before return to service.