NSW Gasfitting study plan
NSW Gasfitting · Give each week a clear focus.
8 weeks · About 6 hours per week
Gas regulations, standards and licensing obligations & Gas properties, combustion and ventilation
Map each domain's weighting to a weekly time budget and write it down as a one-page schedule
Summarise the licensing, notification and record-keeping duties that attach to gasfitting work in NSW into a checklist
Define the combustion equation for natural gas and LPG and calculate theoretical air requirements for three sample inputs
List the AS/NZS standards and regulatory instruments you must be able to locate by name, and note what each covers
Your checkpoint
A one-page study schedule plus a compliance checklist covering licensing, notification and record-keeping duties
Gas properties, combustion and ventilation
Calculate stoichiometric air, excess air and CO2 percentages for at least five worked fuel/air scenarios
Explain how incomplete combustion arises from air deficiency, flame impingement and poor burner condition
Determine ventilation requirements for an enclosed space using appliance input and room volume
Classify the physical properties of natural gas and LPG that drive installation decisions, including relative density and flammability limits
Your checkpoint
A worked problem set of ten combustion and ventilation calculations with answers and method notes
Installation of gas appliances and pipework & Gas properties, combustion and ventilation
Size gas pipework for three realistic installations using pressure drop and load tables
Draft a pipework layout showing isolation, sleeving, support spacing and clearances to other services
Select flueing arrangements appropriate to appliance type and location, and justify each choice
Identify clearances and ventilation openings required for a range of appliance categories
Your checkpoint
Three completed pipe sizing sheets with layouts and a written justification for each flue selection
Installation of gas appliances and pipework & Commissioning, testing and fault finding
Sequence the commissioning steps for a new installation from purge through to consumer handover
Perform and record a pressure test and a leak test to the required test pressures and durations
Describe how to verify operating pressure, gas rate and combustion performance at the appliance
Assemble a handover pack listing what the consumer must be told and what must be left on site
Your checkpoint
A complete commissioning and handover record for a simulated installation, including test results
Commissioning, testing and fault finding
Build a fault-finding decision tree covering no ignition, poor flame, low heat output and intermittent operation
Diagnose five written fault scenarios and state the test that confirms each diagnosis
Interpret combustion analyser readings and identify the likely cause of out-of-spec CO or CO2 values
Explain how to isolate and make safe a defective appliance before repair
Your checkpoint
A fault-finding flowchart plus written diagnoses for five scenarios with confirming tests
Safety, consumer protection and environmental requirements & Gas regulations, standards and licensing obligations
Summarise consumer protection obligations including disclosure, warranties and complaint handling
Identify environmental duties covering spillage, refrigerant and gas release, and waste disposal
List personal and site safety controls required before and during gasfitting work
Explain the process for reporting notifiable incidents and unsafe installations
Your checkpoint
A two-page safety and consumer protection reference sheet covering obligations, incident reporting and environmental duties
Commissioning, testing and fault finding & Safety, consumer protection and environmental requirements
Re-run two timed commissioning scenarios to build speed and accuracy under exam conditions
Complete a mixed set of calculation questions across combustion, ventilation and pipe sizing
Review every previously missed question and write a corrected method for each
Practise explaining a safety decision aloud as you would to a consumer
Your checkpoint
A log of all errors from timed practice with corrected methods recorded against each
Gas regulations, standards and licensing obligations & Gas properties, combustion and ventilation & Installation of gas appliances and pipework & Commissioning, testing and fault finding & Safety, consumer protection and environmental requirements
Complete two full-length timed practice exams and score each by domain
Revisit the two lowest-scoring domains and close the specific gaps identified
Recite the key standards, test pressures and clearances from memory without notes
Finalise a one-page exam-day reference of figures and formulas you must recall
Your checkpoint
Two scored practice exams with a domain-by-domain gap analysis and a final one-page reference sheet
Milestones
Week 2: Score at least 80% on a self-marked ten-question combustion and ventilation calculation set without notes
Week 4: Produce a commissioning record with correct test pressures, durations and results, and explain each step aloud without referring to notes
Week 6: Correctly diagnose at least four of five fault scenarios and state the confirming test for each
Week 8: Achieve at least 75% overall on each full-length practice exam, with no domain below 65%