Accessibility Fundamentals and Regulatory Framework

  • ADA Title II covers state and local government entities; Title III covers public accommodations and commercial facilities; Title I covers employment.

  • The 2010 ADA Standards for Accessible Design govern new construction and alterations; the 1991 Standards still apply to elements not altered until altered.

  • For Title II and Title III, compliance with the 2010 Standards is required for covered elements; safe harbor protects elements compliant with 1991 Standards until altered.

  • Accessible route and element dimensions are measured to the finished surface, and clear width is measured between the widest points of opposing elements.

  • Reach ranges: unobstructed high forward reach 48 in max, low forward reach 15 in min; obstructed high reach 48 in max with reach depth limits per table.

  • Operable parts must be operable with one hand, without tight grasping, pinching, or twisting, using no more than 5 lbf of force.

  • Protruding objects: wall-mounted objects with leading edge 27 to 80 in above floor may protrude 4 in max; freestanding objects detectable by cane are permitted.

  • A single accessible route must connect site arrival points, accessible entrances, and all accessible spaces within the site.

Quick reference

Accessible Routes, Site Access, and Parking

  • Accessible route clear width is 36 in min; passing spaces of 60 by 60 in are required at intervals of 200 ft max where route is less than 60 in wide.

  • Route surface must be firm, stable, and slip resistant; changes in level up to 1/4 in may be vertical, 1/4 to 1/2 in must be beveled, and over 1/2 in requires a ramp.

  • Running slope of an accessible route is 1:20 max; steeper than 1:20 is a ramp. Cross slope is 1:48 max.

  • Accessible parking: car 96 in min width, van 132 in min width; access aisle 60 in min, two spaces may share one aisle.

  • Van-accessible spaces require a 98 in min vertical clearance at the space, aisle, and vehicular route.

  • Number of accessible spaces scales with total spaces: 1 for 1-25, 2 for 26-50, 3 for 51-75, 4 for 76-100, then increments per the standards table.

  • One in every six accessible spaces, and at least one, must be van accessible; signage with International Symbol of Access is required at each accessible space.

  • Access aisles must be marked, may not overlap the vehicular way, and must connect to an accessible route to the building entrance.

Quick reference

Building Entrances, Doors, and Interior Circulation

  • At least one accessible entrance must be provided; if not all entrances are accessible, the accessible entrance must be on an accessible route and identified by signage.

  • Door clear opening width is 32 in min measured between the face of the door and the stop, with the door open 90 degrees.

  • Maneuvering clearance at doors depends on approach direction and door swing; a front approach to a swinging door requires 60 in min depth on the pull side.

  • Door hardware must be operable with one hand and no tight grasping, pinching, or twisting; 5 lbf max operating force for interior hinged doors.

  • Thresholds at doorways are 1/2 in max high and must be beveled on both sides if over 1/4 in.

  • Accessible routes within a building must connect accessible entrances, spaces, and elements; corridors serving accessible spaces must be 36 in min clear.

  • Two-way traffic in a corridor requires 60 in min width, or passing spaces at 200 ft max intervals.

  • Automatic and power-assisted doors must comply with opening force and timing limits; closing speed and opening duration are specified for accessibility.

Quick reference

Accessible Plumbing Fixtures and Plumbing Elements

  • Water closets in accessible compartments require 60 in min width compartment and 56 in min depth for wall-hung or 59 in for floor-mounted per standards.

  • Grab bars are required on the rear and side walls; side wall grab bar is 42 in min long, rear wall grab bar is 36 in min long.

  • Water closet seat height is 17 to 19 in measured to the top of the seat; flush controls must be operable with 5 lbf max.

  • Lavatories require 29 in min knee clearance, 30 in min width, and 27 in min high clearance at the front edge; pipes must be insulated or concealed.

  • Mirrors above lavatories must have the bottom edge at 40 in max above the floor when mounted over an obstruction.

  • Accessible toilet compartments: 60 in wide by 56 in deep for wall-hung water closets, or 60 in wide by 59 in deep for floor-mounted water closets.

  • Urinals must have an elongated rim with the top at 17 in max above the floor; clear floor space 30 by 48 in is required.

  • Shower and tub controls, seats, and grab bars have specified locations and heights in the standards; shower seats are required in standard roll-in showers.

Quick reference

Ramps, Stairs, and Elevators/Lifts

  • Ramp running slope is 1:12 max; cross slope is 1:48 max; ramp rise over 30 in requires a landing.

  • Ramp landings: top and bottom landings 60 in min length, intermediate landings 60 in min length at each 30 in max rise.

  • Ramp width is 36 in min clear between handrails; handrails are required on both sides of ramps with rise greater than 6 in.

  • Handrail height is 34 to 38 in above the ramp surface; extensions must be provided at the top and bottom of the ramp.

  • Edge protection is required on ramps; a curb or barrier prevents a 4 in sphere from passing.

  • Stair treads and risers: riser height 4 to 7 in, tread depth 11 in min; nosings must be detectable and have a radius of 1/2 in max.

  • Elevator car dimensions: 36 in min door clear width; car size depends on the type; a 48 in min deep car is required for some configurations.

  • Platform lifts are permitted as an alternative to ramps in certain conditions, such as within a dwelling unit or where terrain prevents a ramp.

Quick reference

Communication Elements, Signage, and Assistive Listening

  • Signs identifying permanent rooms and spaces must have raised characters and braille, and must be mounted on the wall adjacent to the latch side of the door.

  • Tactile signs must be mounted 48 to 60 in above the finished floor to the baseline of the highest raised character.

  • Visual character height on tactile signs is 5/8 to 2 in; raised characters must be sans serif and not italic or oblique.

  • Assistive listening systems are required in assembly areas with audio amplification and seating capacity of 50 or more, per the standards table.

  • Number of assistive listening receivers required is based on seating capacity; a percentage of receivers must be hearing-aid compatible.

  • Visual alarms and notification appliances are required in accessible spaces and public and common use areas in certain occupancies.

  • Signs directing to accessible entrances and accessible features must include the International Symbol of Accessibility.

  • Two-way communication systems at accessible entrances must be operable with 5 lbf max and positioned within reach ranges.

Quick reference

Recreation, Assembly, and Special Occupancy Spaces

  • Assembly areas with fixed seating require wheelchair spaces and companion seats; the number of wheelchair spaces is based on seating capacity.

  • Wheelchair spaces must be an integral part of the seating plan, provide a 30 by 48 in clear floor space, and have a line of sight comparable to adjacent seats.

  • Companion seats must be provided adjacent to wheelchair spaces at a ratio of at least one companion seat per wheelchair space.

  • Dispersion requirements apply to wheelchair spaces and companion seats across seating types and price ranges in assembly areas.

  • Recreational facilities such as swimming pools, play areas, and exercise machines have specific accessible route and transfer requirements in the standards.

  • Team player seating areas and accessible routes to playing surfaces are required in certain recreation facilities.

  • Dressing, fitting, and locker rooms must have accessible elements including benches and accessible routes.

  • Accessible guest rooms in hotels must have specified numbers of accessible rooms with roll-in showers and visual alarms.

Quick reference

Existing Facilities, Alterations, and Transition Planning

  • Alterations must comply with the 2010 Standards to the maximum extent feasible; if full compliance is structurally impracticable, alternative compliance is allowed.

  • Path of travel to altered areas must be accessible to the extent that the cost of providing access is not disproportionate to the overall alteration cost.

  • The disproportionate cost threshold is 20 percent of the cost of the alteration to the primary function area.

  • Safe harbor applies to elements compliant with the 1991 Standards and not altered after March 15, 2012; those elements need not be upgraded until altered.

  • Title II entities must conduct a self-evaluation and develop a transition plan if structural changes are needed to achieve program access.

  • Transition plans must identify physical obstacles, describe methods to make facilities accessible, specify a schedule, and identify the official responsible.

  • Program access requires that each program, when viewed in its entirety, be readily accessible to and usable by individuals with disabilities.

  • New construction after the effective date of the 2010 Standards must comply fully with the 2010 Standards; no safe harbor for new elements.

Quick reference

Inspection, Documentation, and Compliance Reporting

  • Inspection should verify dimensions with a measuring tape or digital level, and document each element against the applicable standard citation.

  • Common inspection findings include missing or incorrect grab bars, insufficient clear floor space, and noncompliant door hardware.

  • Photographs, measurements, and notes should be recorded for each finding; documentation should identify the standard section and the observed condition.

  • A compliance report should distinguish between compliant elements, noncompliant elements, and elements not applicable.

  • Accessible route continuity should be verified from the site arrival point to the accessible entrance and through the building to all accessible spaces.

  • Tolerance for field measurements should be noted, and any measurement within a small tolerance of the limit should be flagged for review.

  • Reports should include a summary of findings, prioritized remediation recommendations, and a schedule for corrections where applicable.

  • Documentation should record the date, inspector, weather conditions, and instruments used for measurements.