- Workset ownership
- A workset is editable by exactly one user at a time. Other users see it read-only until the owner relinquishes it, which prevents conflicting edits in a shared central model.
- Central and local model
- The central model is the master copy stored on a network share. Each user opens a local copy and synchronizes changes back to the central model through Synchronize with Central.
- Element borrowing
- When a user edits an element in a workset they do not own, Revit borrows that element and locks it for others until the user relinquishes it or syncs.
- Acquire Coordinates
- A command that copies the shared coordinate system from a linked model into the current model, aligning both models to a common survey point and project base point.
- Coordination Review
- A tool that reports changes to monitored elements, such as levels or grids copied from a linked model, and lets the user accept, reject, or postpone each change.
- Distribution system definition
- A named combination of voltage, phases, and wires, such as 277/480 Wye, defined in Electrical Settings and assigned to panels to enable circuiting and scheduling.
- Voltage tolerance range
- A minimum and maximum voltage defined alongside a nominal voltage. Revit uses the range to decide whether a device's voltage matches a distribution system.
- Load classification
- A category of electrical load, such as lighting or receptacles, used to group loads for demand factors and load summaries in panel schedules.
- Conduit settings bend limits
- The minimum and maximum bend angle and the bend radius defined per conduit type. Revit rejects or adjusts bends that exceed these limits during routing.
- Electrical connector load
- The apparent or true power value on an electrical connector. It is summed into the circuit's connected load and reported in the panel schedule.
- Create Circuit
- A command that assigns a selected electrical connector to a new circuit on a panel. The panel then issues the circuit a number and slot.
- Spare versus space
- A spare is an unused circuit position that consumes a number. A space is an empty slot that does not consume a circuit number, preserving numbering downstream.
- Instance versus type parameter
- An instance parameter can differ per placed element, such as each fixture's load. A type parameter is shared by every instance of that family type.
- Demand factor
- A multiplier applied to connected load to produce demand load. It is defined at the load classification or panel level and changes the schedule's calculated demand.
- Face-based lighting fixture
- A lighting fixture family that hosts on a surface rather than a work plane. It snaps to native or linked surfaces and follows the host's orientation.
- Space enclosure requirement
- A space must be enclosed by bounding elements to report volume. Unenclosed spaces are excluded from load and lighting analysis until boundaries are fixed.
- Space Naming Utility
- A tool that copies room names and numbers from linked architectural models into MEP spaces, keeping tags and schedules consistent after architectural changes.
- Mounting height parameter
- A family parameter recording the intended installation height of a device. Schedules report it for coordination instead of relying on the modeled elevation.
- Panel schedule template
- A reusable definition controlling column headers, load summary sections, and spare/space display. Panels inherit the template assigned to them.
- Connected versus demand load
- Connected load is the arithmetic sum of all assigned circuit loads. Demand load applies demand factors to connected load and is the value used for sizing decisions.
- Circuit slot numbering
- Circuit numbers follow panel slots in order. Inserting a spare or space shifts downstream numbers, so positions should be finalized before circuits are annotated.
- Phase balancing display
- The panel schedule shows L1, L2, and L3 loading columns. Moving circuits between slots changes per-phase totals and the resulting imbalance shown in the summary.
- Edit Circuits mode
- A panel editing state that lets the user reassign circuit slots, rename circuits, and move circuits between panels, with the schedule updating immediately.
- Conduit without fittings
- A conduit modeling mode that draws a continuous run without placing fittings at direction changes, useful for schematic routing before final coordination.
- Automatic conduit bends
- Bends generated when a conduit run changes direction. Their radius and angle come from the conduit type's settings, and over-limit geometry is rejected.
- Cable tray fittings
- Elbows, tees, and crosses placed automatically where a cable tray run changes direction or branches, sized according to the tray type definition.
- Interference Check
- A tool that reports intersections between selected categories, such as conduit and structural framing, producing a list of clashing element pairs for review.
- Tag by Category
- A command that places a tag on a selected element using the loaded tag family appropriate to that element's category and its labeled parameter.
- Circuit number tag
- An electrical tag whose label references the circuit number and panel name system parameters, displaying circuiting information directly in plan views.
- Calculated value field
- A schedule field computed from a formula using other fields, used to derive values such as load per area or total connected load per panel.
- Keynote versus tag
- A keynote references a keynote file and applies across categories. A tag references a parameter on a specific family and applies only to that category.
- View title on sheet
- A view property controlling the title text shown beneath a view placed on a sheet, independent of the view's name in the Project Browser.