BCSCP study materials
BCSCP study resources

BCSCP cheat sheet

BCSCP · Keep the key ideas within reach.

Quick reference

Sterile Compounding Process and Technique

  • USP <797> classifies CSPs as immediate-use, Category 1, or Category 2; assignment depends on starting ingredients, processing steps, and engineering controls.

  • Immediate-use CSP administration must begin within 1 hour of preparation start; no storage and no longer beyond-use date are permitted.

  • Category 1 CSP beyond-use date: 12 hours at controlled room temperature and 24 hours refrigerated; frozen storage requires validated stability data.

  • Category 2 CSP beyond-use date: 4 days at controlled room temperature, 10 days refrigerated, and 45 days frozen.

  • Disinfect CSP contact surfaces with sterile 70% isopropyl alcohol and allow to dry; work at least 6 inches inside the ISO 5 primary engineering control.

  • First-air rule: no object may be placed between the HEPA filter and the critical site; airflow must reach the critical site before any other surface.

  • Swab vial stoppers with sterile 70% isopropyl alcohol and let dry before needle entry; use a new needle for each entry when possible.

  • Final CSP label includes patient name, drug, strength, dose, route, volume, beyond-use date/time, storage, preparation date/time, and preparer/verifier.

Quick reference

Facilities, Equipment, and Environmental Monitoring

  • Category 2 facility design: ISO 5 primary engineering control inside an ISO 7 buffer room, with an ISO 8 ante room and a positive pressure cascade.

  • ISO 5 particle limit: no more than 3,520 particles ≥0.5 µm per cubic meter; ISO 7 limit is 352,000 particles/m³.

  • Pressure differential between adjacent compounding rooms must be at least 0.02 inches water column (5 Pa); monitor continuously with alarm.

  • Certify each ISO 5 primary engineering control every 6 months and after relocation, repair, or HEPA filter change.

  • Perform viable air and surface sampling in each ISO 5 PEC and buffer/ante room at least every 6 months.

  • Unidirectional airflow velocity at the work surface is 0.45 m/s (90 fpm) ±20%; verify by airflow visualization and certification.

  • Maintain buffer and ante room temperature at 20–25°C and relative humidity below 60%; monitor and document.

Quick reference

Quality Assurance and Quality Control

  • Media fill simulates compounding to detect contamination; incubate 14 days and investigate any positive result as a process failure.

  • Gloved fingertip and thumb sampling: initial three consecutive zero-CFU sets before independent compounding, then at least every 6 months.

  • Sterility testing uses USP <71>; it is required for high-risk CSPs and when validation supports extended beyond-use dates.

  • Bacterial endotoxin testing uses USP <85>; limits depend on route of administration and patient weight.

  • Visual inspection of the final container: check against black and white backgrounds for particles, discoloration, leakage, and container defects.

  • Master formulation record includes ingredients, quantities, order of mixing, equipment, sterilization method, beyond-use date, and quality control checks.

  • Pharmacist release verification includes calculations, ingredients, label, final container, and documentation before the CSP leaves the pharmacy.

Quick reference

Personnel Training, Competency Assessment, and Safety

  • Garbing order: shoe covers, head/hair cover, face mask, eye protection, hand hygiene, sterile gown, then sterile gloves.

  • Perform hand hygiene before garbing and again before gloving; use soap and water or an alcohol-based rub per policy.

  • Initial competency requires documented training and visual observation before independent compounding; reassess technique at least annually.

  • Gloved fingertip sampling is required initially and at least every 6 months; three consecutive zero-CFU sets are needed before independent compounding.

  • HD PPE minimum: two pairs of chemotherapy-tested gloves, closed-front gown, eye and face protection, and NIOSH-approved respirator when aerosol risk exists.

  • Safety data sheet for every hazardous drug must be readily accessible to staff before handling.

  • Spill kit contents: chemotherapy gloves, gown, eye protection, absorbent pads, detergent, deactivation agent, and hazardous waste bags.

Quick reference

Hazardous Drug Handling and Related Regulations

  • USP <800> applies to all healthcare personnel who handle hazardous drugs; NIOSH lists groups 1, 2, and 3.

  • NIOSH Group 1: antineoplastic hazardous drugs; require full containment and engineered controls.

  • NIOSH Group 2: non-antineoplastic hazardous drugs; require containment and safe handling based on a documented risk assessment.

  • HD compounding room: negative pressure at 0.01 inches water column (2.5 Pa) relative to adjacent areas and at least 12 air changes per hour.

  • Containment primary engineering control for HDs must be externally vented; Class II or III biological safety cabinet is preferred.

  • Deactivation, decontamination, and cleaning must be performed in that order using agents proven effective for the specific hazardous drug.

  • Hazardous drug waste goes into chemotherapy waste containers labeled hazardous; do not compact.

Quick reference

Patient Safety, Risk Management, and Continuous Quality Improvement

  • FMEA is prospective: risk priority number = severity × occurrence × detection; higher scores prioritize process improvements.

  • Root cause analysis is retrospective for sentinel events; identify system causes rather than individual blame.

  • Independent double check: two qualified staff separately verify high-alert drug, dose, calculation, and pump settings before administration.

  • Just culture supports nonpunitive reporting of errors and near misses while maintaining accountability for reckless behavior.

  • High-alert medications require tall-man lettering, auxiliary labels, and separate storage to reduce look-alike/sound-alike errors.

  • Track compounding errors, contamination rates, and turnaround times; compare against benchmarks and set improvement targets.

  • PDCA (Plan-Do-Check-Act) is an iterative method for testing, measuring, and sustaining quality improvement changes.