BTEB Masonry · Put your knowledge to work in context.

All case studies

Movement Joint Omission in a Long Garden Wall

You are building a free-standing garden wall, 22 m long, 1.8 m high, one brick thick (215 mm), in stretcher bond with a cement–lime mortar. The drawing shows movement joints at 12 m centres, but the setting-out on site means a joint would fall in the middle of a decorative pier, so the foreman tells you to leave it out and 'just build through'. The wall is on a south-facing boundary with no shade, and the bricks are a fairly strong facing brick. There is a pier at each end and one at 11 m.

1. Explain why omitting the movement joint is a risk on this wall, referring to the wall's proportions and exposure.

Read the worked answer

A 22 m long, 1.8 m high, one-brick-thick wall is a slender, unrestrained element with a high length-to-height ratio. It will move with moisture and temperature: bricks expand slightly over time as they take up moisture, and the wall expands and contracts with temperature, especially on a shaded-free south-facing elevation.

Movement joints are provided to accommodate that movement in controlled locations. Without a joint, the movement is restrained between the end piers and the 11 m pier, and the stress concentrates where the wall is weakest - often at a pier junction or a course with poor bond. The likely result is vertical cracking, bulging, or displacement of the coping and piers.

The 12 m spacing on the drawing is the designer's allowance for this wall; halving the distance between restraints by building through does not remove the movement, it just forces it into the masonry.

2. Propose a practical resolution that keeps the pier and satisfies the movement requirement, and state what you would record.

Read the worked answer

Resolution options:

  1. Re-position the joint so it falls clear of the decorative pier - for example, move the pier or adjust the joint to a plain panel between piers, keeping joint spacing within the designer's maximum.
  2. If the pier cannot move, form the joint tight against one face of the pier with a proper slip detail, so the pier is not bonded across the joint.
  3. Refer back to the designer for a revised joint layout; the 12 m spacing is a maximum, not a target, and the designer may accept a different arrangement if the restraint conditions are checked.

What to record: the as-built joint positions, the reason for any deviation, the designer's written confirmation, and the date. Do not build through and rely on pointing later; a crack that opens after pointing is a defect, not a finish.