FSCD Station Officer Exam flashcards
FSCD Station Officer Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fire Tetrahedron
- The four elements needed for combustion are fuel, oxygen, heat, and an uninhibited chemical chain reaction. Removing or interrupting any one element stops flaming combustion.
- Flashover
- The near-simultaneous ignition of all combustible contents and gases in a compartment, typically when upper-layer temperatures reach about 1,100 to 1,200 degrees Fahrenheit.
- Transitional Attack
- An exterior stream directed at ceiling-level gases to cool the upper layer before interior crews advance. It reduces flashover potential but does not replace an interior attack.
- National Fire Academy Fire Flow
- A quick estimate of needed flow for a fully involved compartment: multiply length by width by height in feet, then divide by 100 to get gallons per minute.
- Span of Control
- The number of subordinates one supervisor can effectively direct. Incident command targets three to seven, with five as the working optimum.
- Command Transfer
- A face-to-face briefing between the outgoing and incoming incident commander covering conditions, actions taken, resources assigned, and the current plan.
- Passport Accountability System
- A tag or passport collected at the entry control point that records each member's name, assignment, and entry time so personnel can be tracked inside the hazard zone.
- Mayday Transmission
- A radio report from a firefighter who is lost, trapped, or out of air. It states location, unit, name, assignment, and resources needed.
- Means of Egress
- A continuous and unobstructed path from any point in a building to a public way, made up of exit access, the exit, and exit discharge.
- Occupant Load
- The calculated number of people a space may hold, derived from floor area divided by the adopted code's square-feet-per-person factor for the occupancy.
- Fire Watch
- A temporary patrol or posting required when a fire protection system is impaired or during hot work, to detect and report fire immediately.
- Lightweight Truss Collapse
- Engineered wood trusses and I-joists fail quickly under direct flame, often within five to ten minutes, so crews should avoid operating beneath them.
- Balloon Frame Construction
- A wood-frame method with continuous studs running from foundation to roof, creating an open channel that allows fire to spread vertically inside walls.
- Neutral Plane
- The horizontal boundary in a compartment between hot smoke overhead and cooler air below. Its height indicates fire conditions and ventilation effectiveness.
- Type IV Heavy Timber
- Construction with noncombustible exterior walls and large exposed wood structural members. Heavy timber chars slowly and resists collapse longer than light wood.
- ERG Orange Guide
- The Emergency Response Guidebook section that gives protective actions, health hazards, and firefighting guidance for a material identified by UN number or name.
- Flash Point
- The lowest temperature at which a liquid gives off enough vapor to ignite briefly when exposed to an ignition source. Gasoline is about minus 45 degrees Fahrenheit.
- Defensive Hazmat Operation
- Actions taken outside the hot zone, such as isolation, diking, and evacuation, without contact with the material. Requires training and PPE appropriate to the task.
- Decontamination Corridor
- A sequenced station arrangement for reducing contamination: tool drop, gross decon, secondary decon, and medical monitoring before release from the scene.
- START Triage
- Simple triage and rapid treatment sorts patients by respirations, perfusion, and mental status into green, yellow, red, and black categories.
- Adult CPR Compressions
- Chest compressions at 100 to 120 per minute, 2 to 2.4 inches deep, with full recoil and a 30-to-2 compression-to-ventilation ratio.
- Vehicle Stabilization
- Cribbing, chocks, and struts placed before patient contact to prevent movement during extrication. Battery and restraint systems are managed as part of the plan.
- Friction Loss Formula
- Friction loss equals the hose coefficient times flow in hundreds of gallons per minute squared, times length in hundreds of feet.
- Pump Discharge Pressure
- The sum of nozzle pressure, total friction loss, elevation loss or gain, and appliance loss. Elevation changes add or subtract 0.5 psi per foot.
- Drafting Limit
- The practical lift for a fire pump is about 25 feet at sea level. Altitude, worn pumps, and intake leaks reduce that height.
- Relay Pumping
- A series of pumpers moving water over distance. Each pumper maintains a positive intake pressure, and manifolds or dump valves balance flow.
- Progressive Discipline
- A documented sequence of corrective actions, from coaching through warnings and suspension, applied consistently with policy and any labor agreement.
- After-Action Review
- A structured debrief covering what was planned, what occurred, why it happened, and what changes are needed for future operations.
- NFIRS Basic Module
- The required National Fire Incident Reporting System record completed for every incident, capturing location, incident type, actions taken, and casualties.
- Respiratory Protection Program
- The written OSHA-required program including medical evaluation, fit testing, training, maintenance, and recordkeeping for respirator users.
- Risk Management Principle
- Risks are accepted only when the potential benefit outweighs the danger. No risk is taken to save a life already lost or property that cannot be saved.
- Rapid Intervention Team
- A dedicated crew staged at a working fire with tools and hose, ready to locate and rescue trapped or disoriented firefighters.