Bulgarian Energy Efficiency Consultant Exam flashcards
Bulgarian Energy Efficiency Consultant Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- ZEE
- Bulgarian Energy Efficiency Act; transposes EU Energy Efficiency Directive 2012/27/EU, mandates energy audits for large enterprises every four years.
- ZEEU
- Bulgarian Energy Performance of Buildings Act; implements EPBD 2010/31/EU, requires energy performance certificates for new buildings, sale, and rent.
- SEDA
- Sustainable Energy Development Agency; Bulgarian authority responsible for registering energy auditors and overseeing energy efficiency certification and audits.
- NZEB renewable share
- Bulgaria requires at least 55% renewable energy share for public NZEBs and typically 35% for other new buildings, per national regulation.
- EN 16247-1
- European standard for energy audits; specifies scope, data collection, analysis, reporting, and quality assurance requirements for a systematic audit.
- Degree-day method
- Heating degree days (HDD) equal the sum of daily differences between a base temperature and mean outdoor temperature when mean is below base; used to estimate heating energy.
- Energy performance indicator
- EnPI is a metric such as kWh/m²·year or kWh/unit production used to normalize and compare energy performance across buildings or processes.
- Audit levels
- Three typical energy audit levels: walk-through screening, detailed audit with measurements and energy balance, and investment-grade audit with financial analysis.
- Thermal transmittance U
- U-value is the rate of heat transfer through a building element per unit area and temperature difference, equal to 1/R_total, in W/m²K.
- Thermal bridging
- Localized areas of increased heat flow at junctions; quantified by linear thermal transmittance Ψ (W/mK) and included in envelope heat loss calculations.
- Air permeability n50
- Air changes per hour at 50 Pa pressure difference, measured by blower door test; NZEB target typically ≤3 h⁻¹ for airtightness.
- Envelope heat loss formula
- Q = U × A × ΔT (W), where U is thermal transmittance, A is area, and ΔT is indoor-outdoor temperature difference; annual energy uses degree days.
- Heat pump COP
- Coefficient of performance equals useful heat output divided by electrical input; seasonal SCOP accounts for varying outdoor temperatures and part-load operation.
- Ventilation heat recovery efficiency
- Ratio of temperature rise of supply air to indoor-outdoor temperature difference; typical 70–85% for balanced mechanical ventilation with heat recovery.
- Lighting power density
- LPD is installed lighting power per floor area (W/m²); typical limits are 10 W/m² for offices and 12 W/m² for retail spaces.
- Boiler seasonal efficiency
- Useful heat output divided by fuel energy input over a season; condensing boilers can exceed 90% based on lower heating value.
- EPC energy class
- Bulgarian scale from A+ (≤15 kWh/m²·year primary energy) to G (>250); based on calculated energy use for standard occupancy.
- EPC validity
- Energy performance certificate is valid for 10 years and required for new buildings, sale, rent, and public buildings over 250 m².
- BREEAM
- Building Research Establishment Environmental Assessment Method; international certification assessing energy, water, materials, indoor environment, and innovation.
- NZEB definition
- Nearly zero-energy building has very high energy performance with a significant share of renewable energy, typically at least 55% in Bulgaria for public buildings.
- Simple payback
- Investment cost divided by annual energy cost savings, expressed in years; a quick screening metric that ignores time value of money.
- Net present value
- NPV sums discounted annual cash flows minus initial investment; a positive NPV indicates the measure is economically acceptable at the chosen discount rate.
- Internal rate of return
- IRR is the discount rate that makes NPV equal to zero; a measure is acceptable if IRR exceeds the required rate of return.
- Levelized cost of energy
- LCOE equals total lifecycle cost divided by total energy produced over the system lifetime; used to compare different energy supply options.
- Solar PV specific yield
- Annual electricity output per installed kilowatt-peak; in Bulgaria typically 1,200–1,400 kWh/kWp·year depending on location and system design.
- Solar thermal collector efficiency
- Ratio of useful heat collected to incident solar radiation; flat-plate collectors typically achieve 40–60% efficiency.
- Heat pump renewable share
- A heat pump qualifies as renewable if its seasonal performance factor (SPF) is at least 2.5, per the Renewable Energy Sources Directive.
- Battery round-trip efficiency
- Ratio of energy discharged to energy charged, typically 85–95% for lithium-ion batteries; affects self-consumption and storage economics.
- IPMVP Option C
- Whole-facility measurement and verification method using utility meter data for the entire building, with adjustments for weather and occupancy changes.
- Baseline period
- Reference period of at least 12 months used to establish pre-retrofit energy use; adjusted for weather, occupancy, and production changes.
- Weather normalization
- Adjusting energy use to a common climate basis using heating/cooling degree days or regression with outdoor temperature, enabling fair comparison.
- M&V savings equation
- Savings equal adjusted baseline energy minus reporting-period energy, with adjustments for changes in occupancy, production, or building use.