Kt/V target
A single-pool Kt/V of at least 1.2 per hemodialysis session given three times weekly; an equivalent urea reduction ratio of at least 65% also indicates adequate clearance.
Intradialytic hypotension first steps
Stop ultrafiltration, place the patient in Trendelenburg position, and give a saline bolus per protocol, then reassess blood pressure before resuming at a lower ultrafiltration rate.
Saline bolus for hypotension
Typically 100-200 mL of 0.9% sodium chloride is infused for symptomatic intradialytic hypotension; hypertonic saline may be used when cramps accompany the pressure drop.
AV fistula assessment
Palpate for a thrill and auscultate for a bruit; a pulsatile access without a thrill suggests inflow stenosis and should be reported before cannulation is attempted.
Heparin dosing during dialysis
A loading dose of roughly 1000 units followed by 500-1500 units per hour keeps the activated clotting time about 1.5-1.8 times baseline, preventing circuit clotting without systemic bleeding.
High venous pressure alarm
Rising venous pressure indicates outflow resistance such as needle infiltration, tubing kink, clot in the venous chamber, or dialyzer fiber clotting; inspect the access and circuit before continuing.
Post-dialysis access hemostasis
Apply firm pressure to both needle sites for 10-15 minutes without eliminating the thrill, then inspect for rebleeding and confirm hemostasis before the patient leaves.
Normal glomerular filtration rate
About 125 mL per minute, producing roughly 180 liters of filtrate daily; urinary output is far smaller because more than 99% of the filtrate is reabsorbed.
Erythropoietin production site
Peritubular interstitial cells of the kidney sense tissue hypoxia and secrete erythropoietin, which stimulates red blood cell production in the bone marrow.
Aldosterone renal action
Released by the adrenal cortex, aldosterone increases sodium reabsorption and potassium secretion in the distal nephron, expanding extracellular fluid volume and raising blood pressure.
CKD stage 5 definition
A glomerular filtration rate below 15 mL/min/1.73 m² defines stage 5 chronic kidney disease, the stage at which dialysis or transplantation is typically required.
Secondary hyperparathyroidism cause
Failing kidneys cannot excrete phosphate or produce calcitriol, so phosphate rises and calcium falls; these changes stimulate parathyroid hormone release and bone resorption.
Antidiuretic hormone action
Antidiuretic hormone released from the posterior pituitary inserts aquaporin channels in collecting duct cells, increasing water reabsorption and concentrating the urine.
KoA of a dialyzer
The mass transfer-area coefficient combines membrane permeability and surface area; a higher KoA means greater small-solute clearance at any given blood and dialysate flow rate.
Ultrafiltration coefficient Kuf
Expressed in mL per hour per mmHg of transmembrane pressure, Kuf describes how much fluid a dialyzer removes for each unit of pressure applied across the membrane.
Countercurrent dialysate flow
Blood and dialysate move in opposite directions through the dialyzer, preserving a concentration gradient along the entire membrane and maximizing solute removal.
Air embolism response
Stop the blood pump, clamp the venous line, position the patient in left lateral Trendelenburg position, and administer 100% oxygen while calling for emergency assistance.
Pre-pump arterial pressure
A negative pressure more negative than about -250 mmHg signals excessive inflow resistance from a kink, small or malpositioned needle, access stenosis, or low blood pressure.
Dialysate conductivity range
Dialysate conductivity normally measures about 13-14 mS/cm; values outside this range call for stopping treatment and verifying concentrate proportioning before resuming.
Total cell volume reuse limit
A reused dialyzer must retain at least 80% of its baseline total cell volume; a lower value indicates fiber clotting and reduced clearance, so the dialyzer is discarded.
Chlorine testing frequency
Total chlorine and chloramine in product water are tested before each shift and after carbon filter changes; the acceptable limit is below 0.1 mg/L.
Carbon filter function
Activated carbon removes chlorine and chloramine from feed water; an exhausted filter allows these oxidants into dialysate and can cause hemolysis and methemoglobinemia.
Reverse osmosis function
High pressure forces feed water through a semipermeable membrane that rejects 90-99% of dissolved ions, bacteria, and endotoxin, producing purified water for dialysate.
Water softener function
A softener exchanges calcium and magnesium for sodium to prevent scale formation; hardness is tested daily and the resin regenerated with brine solution.
Bicarbonate dialysate separation
Bicarbonate concentrate is stored separately from acid concentrate containing calcium and magnesium because combining them would precipitate insoluble calcium carbonate in the dialysate.
Dialysate endotoxin limit
Standard dialysate should contain fewer than 200 colony-forming units per mL of bacteria and less than 2 EU/mL of endotoxin; ultrapure dialysate standards are considerably stricter.
Hepatitis B dialysis precautions
Hepatitis B surface antigen-positive patients are dialyzed in a separate room or area with dedicated equipment, because the virus survives on surfaces and spreads easily within units.
Hepatitis C machine assignment
Hepatitis C infection is not an indication for a dedicated dialysis machine; standard precautions with hand hygiene, gloves, and careful disinfection are considered sufficient.
Needlestick immediate actions
Wash the exposed site with soap and water, report the exposure immediately, and arrange source testing; HIV postexposure prophylaxis is most effective when started within hours.
Blood spill disinfection
Visible blood spills are cleaned with a 1:10 dilution of household bleach, roughly 0.5% sodium hypochlorite, allowing adequate contact time before wiping the surface.
Catheter hub connection care
Both patient and nurse wear masks during catheter connection and disconnection, the hub is scrubbed with chlorhexidine and allowed to dry, and a sterile dressing is applied.
Sharps handling rules
Needles are never recapped, bent, or broken; the safety device is activated and the needle dropped directly into a puncture-resistant sharps container at the point of use.