BPI BSP study materials
BPI BSP study resources

BPI BSP flashcards

BPI BSP · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

House as a system
A house is an interacting system of enclosure, HVAC, occupants, and environment; changing one part affects air, heat, and moisture movement elsewhere.
Stack effect
Warm indoor air rises and escapes high in a building while outdoor air enters low, creating pressure differences driven by height and temperature difference.
Pressure boundary
The continuous surface separating conditioned from unconditioned space; it should align with insulation to reduce condensation risk inside assemblies.
Sensible heat
Heat that changes a material's temperature without changing its phase; measured with a thermometer and expressed in Btu or joules.
Latent heat
Heat absorbed or released during a phase change, such as water evaporating or condensing, without a temperature change.
BTU
The amount of energy needed to raise one pound of water by one degree Fahrenheit; a common unit for heating and cooling capacity.
Controlled ventilation
Deliberate outdoor air supply or exhaust using fans or ducted systems, provided after air sealing to maintain indoor air quality.
Conduction
Heat transfer through direct contact within a solid material or between materials, driven by a temperature difference.
Convection
Heat transfer by moving fluid such as air or water; in buildings, buoyancy and fans drive convective loops and air leakage.
Radiation
Heat transfer by electromagnetic waves between surfaces; it does not require a medium and depends on surface temperature and emissivity.
R-value
A measure of thermal resistance; higher R-value means better resistance to conductive heat flow for a given thickness and material.
U-value
The rate of heat flow through a material or assembly divided by area and temperature difference; it equals 1 divided by R-value.
Dew point
The temperature at which air reaches saturation and water vapor begins to condense onto surfaces at or below that temperature.
Vapor diffusion
Movement of water vapor through materials driven by vapor pressure differences; usually slower than air transport in buildings.
Air barrier
A continuous material or system that limits uncontrolled air movement between conditioned and unconditioned spaces, including seams, penetrations, and transitions.
Thermal bridging
Heat flow through framing, fasteners, or other conductive paths that bypass insulation, reducing the assembly's effective R-value.
Closed-cell spray foam
A high-density foam insulation that provides thermal resistance, air sealing, and a vapor retarder in one application.
Rain screen
A cladding system with a drained and ventilated cavity behind it, allowing bulk water to drain and walls to dry.
Class II vapor retarder
A material with permeance between 0.1 and 1.0 perm, often used to limit vapor diffusion while allowing some drying.
Continuous insulation
Insulation installed outside framing without thermal breaks, reducing thermal bridging and improving effective R-value.
AFUE
Annual Fuel Utilization Efficiency; the percentage of fuel energy converted to useful heat over a heating season, with higher values indicating greater efficiency.
SEER2
A seasonal cooling efficiency rating for air conditioners and heat pumps; higher SEER2 indicates more efficient cooling performance.
Heat pump COP
Coefficient of performance; useful heating or cooling output divided by electrical energy input, often greater than one because heat is moved rather than generated.
Duct leakage
Unintended air loss from ducts, which reduces delivered capacity and can draw pollutants or moisture into the system.
HRV
Heat recovery ventilator; a balanced ventilation device that transfers sensible heat between exhaust and supply air streams.
ERV
Energy recovery ventilator; a balanced ventilator that transfers both sensible heat and latent moisture between exhaust and incoming air.
Carbon monoxide
A colorless, odorless gas produced by incomplete combustion; it interferes with oxygen transport in blood and can be fatal.
Relative humidity
The amount of water vapor in air expressed as a percentage of the maximum it can hold at that temperature.
Radon
A radioactive soil gas that can enter buildings through foundation cracks and openings; long-term exposure increases lung cancer risk.
Backdrafting
Reverse flow of combustion gases into a building caused by depressurization or inadequate draft, creating carbon monoxide and health risks.
Source control
Reducing indoor pollutants at their origin by selecting low-emission materials and isolating sources such as garages or combustion appliances.
ASHRAE 62.2
A residential ventilation standard that specifies minimum outdoor air ventilation and local exhaust requirements for acceptable indoor air quality.