BPI HHP flashcards
BPI HHP · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Keep it dry
- The first healthy housing principle: control bulk water, vapor, and leaks so building materials stay dry, preventing mold, pests, decay, and contaminant release.
- Hierarchy of controls
- Ranking of hazard interventions from most to least effective: elimination, substitution, engineering controls, administrative controls, and personal protective equipment last.
- Bulk water transport
- Liquid water moving under gravity or pressure through roof failures, flashing gaps, and grade problems; the largest moisture source and fixed by drainage, not sealants.
- Capillary action
- Moisture wicking through porous materials and narrow gaps against gravity, drawing water into framing, masonry, and soil contact points.
- Air-transported moisture
- Water vapor carried by air leaks through the envelope; it moves far more moisture than diffusion and is controlled by air sealing.
- Vapor diffusion
- Slow movement of water vapor through materials driven by vapor pressure differences; smallest moisture transport mechanism, managed with vapor retarders.
- Bath fan sizing rule
- Intermittent bath exhaust is typically sized near 50 cfm or about one cfm per square foot of bathroom floor area, run until humidity drops.
- Backdrafting
- Reversal of combustion flue flow caused by depressurization, pulling carbon monoxide and flue gases back into the living space instead of outdoors.
- Carbon monoxide alarm
- Device that sounds when CO reaches dangerous levels; required near sleeping areas because CO is odorless and symptoms resemble flu.
- Radon action level
- The 4 pCi/L threshold at which mitigation is recommended; radon is a soil gas entering foundations and a leading cause of lung cancer.
- MERV rating
- Minimum Efficiency Reporting Value describing filter particle capture; MERV 8 or higher captures respirable particles when the filter fits properly.
- Integrated pest management
- Sequence of identifying the pest, removing food, water, and shelter, excluding entry, then applying least-toxic pesticide only as a last resort.
- Lead paint presumption
- Homes built before 1978 are presumed to contain lead paint, requiring certified renovators and lead-safe work practices during disturbance.
- Lead dust friction surfaces
- Windows, doors, and floors where painted surfaces rub and generate lead dust; bare soil near the drip line is also a hazard.
- Asbestos suspect materials
- Pre-1980 pipe insulation, floor tile, and joint compound are presumed to contain asbestos; sample before any disturbance and use licensed abatement.
- Scald prevention temperature
- Setting the water heater to 120 degrees Fahrenheit reduces burn risk at taps while still limiting Legionella growth in the tank.
- Smoke alarm placement
- Working smoke alarms on each level and near sleeping areas, tested monthly and replaced per manufacturer interval; interconnection improves warning.
- Assessment sequence
- Standardized walk-through order: exterior, interior room by room, mechanical systems, then resident education, with conditions, locations, and photos documented.
- Risk-based prioritization
- Ordering repairs by hazard severity: imminent hazards such as no heat or gas leaks first, then contributing conditions, then general improvements.
- Deferred maintenance cascade
- Small unrepaired defects compound over time; a minor roof leak becomes rot, mold, and pest entry within a season.
- Follow-up verification
- Re-inspection confirming the repair removed the hazard rather than the symptom, using the same method and instrument as the baseline.
- Thermal control
- Maintaining safe, stable indoor temperatures; extreme heat or cold is a health hazard affecting older adults and people with chronic illness.
- Envelope before equipment
- Air sealing and insulating the envelope before resizing HVAC, because reduced load improves comfort and ventilation balance.
- Duct leakage risk
- Leaky ducts in unconditioned space waste energy and can draw contaminants from attics, crawlspaces, or garages into the supply air.
- Blower door test
- Pressurization test quantifying envelope tightness, reported as air changes per hour at 50 pascals and revealing hidden leakage paths.
- Asthma triggers at home
- Mold, dust mites, cockroach and rodent allergen, tobacco smoke, and strong fragrances are common indoor triggers of asthma symptoms.
- Dust mite control
- Encasing bedding, washing in hot water weekly, keeping indoor humidity below 50 percent, and reducing carpet to limit dust mite allergen.
- Secondhand smoke exposure
- No safe exposure level exists; smoke-free housing policy, not ventilation or filtration, is the effective control measure.
- Resident education outcome
- Success measured by observed behavior change such as running bath fans or reporting leaks, not by counting materials distributed.
- Informed consent
- Resident permission obtained before entry, photography, and sampling; residents may decline and confidentiality of health information applies.
- Wood moisture threshold
- Meter readings above roughly 16 to 20 percent wood moisture content indicate conditions that support mold growth and require drying.
- Mold assessment method
- Visual assessment is standard for establishing remediation need; air sampling is not required to determine that mold remediation is necessary.