Stack effect
The upward movement of air through a building caused by temperature differences; warm air rises and creates positive pressure high and negative pressure low, driving infiltration.
Pressure boundary
The continuous plane separating conditioned from unconditioned space; it resists air flow and is the primary target for air sealing in multifamily units.
Compartmentalization
The isolation of each dwelling unit's air boundary from adjacent units and common areas to reduce odor, moisture, and pollutant transfer; verified by guarded blower door testing.
U-value
The overall heat transfer coefficient of an assembly in Btu/h·ft²·°F; lower U-values indicate better insulation. U = 1/R.
ASHRAE 62.2 ventilation rate
Whole-dwelling ventilation formula: Q = 0.03A + 7.5(N+1) CFM, where A is conditioned floor area and N is number of bedrooms.
Infiltration sensible load
Sensible heat gain or loss from air leakage, calculated as 1.08 × CFM × ΔT; used to size HVAC and estimate savings from air sealing.
Thermal bridge
A path of high heat conductance through an assembly, such as a slab edge or steel stud, that bypasses insulation and increases whole-building heat loss.
Blower door test
A diagnostic test that pressurizes or depressurizes a building to 50 Pa and measures airflow (CFM50) to quantify envelope airtightness.
ACH50 to ACHnat conversion
Natural infiltration is estimated as ACH50 divided by N, where N typically ranges from 15 to 20 for multifamily buildings, depending on height and exposure.
Zone pressure diagnostic
A test using a second manometer to measure pressure differences between zones; changes in pressure when a known opening is created reveal dominant leakage paths.
Infrared thermography
An imaging method that detects surface temperature differences to locate insulation gaps, air leakage, and moisture; requires a steady ΔT of at least 10°F.
Duct leakage test
Pressurizing the duct system to 25 Pa and measuring airflow (CFM25) to quantify leakage; results are compared with design airflow to determine pass/fail.
Worst-case depressurization
A combustion safety test that runs all exhaust fans and closes interior doors to create maximum negative pressure, then checks for flue gas spillage.
Ambient CO threshold
The carbon monoxide concentration in conditioned space that triggers action; typically 35 ppm in ambient air during combustion safety testing.
Moisture meter
A pin or pinless instrument that measures wood or building material moisture content; readings above 20% indicate active or recent wetting.
Baseline utility data
Twelve months of gas and electric bills used to establish pre-retrofit energy consumption and EUI, and to calibrate energy models.
Energy use intensity (EUI)
Annual site energy consumption divided by conditioned floor area, expressed in kBtu/ft²·yr; used to compare buildings and track savings.
Degree-day method
An estimation technique using heating or cooling degree days and building UA to predict annual energy use: E = UA × HDD × 24 / η.
Interactive effects
The phenomenon where savings from one measure change the savings from another, such as air sealing reducing the benefit of added insulation.
Calibrated energy model
A simulation adjusted so its annual and monthly energy use matches utility bills within about ±10%, improving savings projections.
Simple payback
Installed measure cost divided by annual energy cost savings; a quick screening metric that ignores measure life and discount rates.
Demand charge
A utility fee based on the peak power (kW) drawn during a billing period; measures that reduce peak load can yield savings beyond energy charges.
TMY3 weather file
A typical meteorological year dataset used in energy modeling to represent long-term average weather conditions for a specific location.
Source vs site energy
Site energy is consumed at the building; source energy includes generation and delivery losses, and is used for comparing fuels on a consistent basis.
Scope of work (SOW)
A written document specifying location, quantity, material, installation method, and acceptance criteria for each retrofit measure.
Change order
A written authorization for work that deviates from the original scope, approved by the program or owner before the work proceeds.
Air sealing specification
A scope item listing specific leakage sites, sealant type, and thickness to be applied, with defined acceptance criteria.
Insulation clearance requirements
Minimum distances between insulation and heat sources, such as 3 inches around recessed lights and 1 inch from chimneys, to prevent fire hazards.
Quality control inspection
A defined verification step at pre-work, rough-in, or final stage, often sampling a percentage of units to confirm SOW compliance.
ASHRAE 62.2
The residential ventilation standard that specifies whole-dwelling and local exhaust airflow rates and acceptable indoor air quality requirements.
ASTM E779
A standard test method for determining air leakage rate by fan pressurization, commonly used for blower door testing.
BPI technical standards
Building Performance Institute documents defining minimum competencies and test procedures for envelope, heating, cooling, and air conditioning work.