CA Fire Alarm key terms
CA Fire Alarm · Get comfortable with the vocabulary.
- Adopted Code Edition
- Related: Authority Having Jurisdiction, Plan Review
The specific published version of a model fire code formally enacted by the authority having jurisdiction, which fixes the technical requirements enforceable on a given project.
- Authority Having Jurisdiction (AHJ)
- Related: Adopted Code Edition, Acceptance Test
The organization, office, or individual empowered to approve equipment, installations, and procedures and to enforce the fire code within a jurisdiction.
- Equivalency
- Related: Authority Having Jurisdiction, Performance-Based Design
An alternative design or method approved by the authority having jurisdiction as providing a level of safety at least equal to the prescriptive code requirement.
- Performance-Based Design
- Related: Equivalency
A fire protection approach in which stated safety goals and design scenarios are met through engineering analysis rather than strict adherence to prescribed prescriptive rules.
- Smoke Detector
- Related: Spot-Type Detector, Detector Spacing
A device that senses visible or invisible combustion particles and sends a signal to the fire alarm control unit; it detects smoke but does not itself sound an alarm.
- Spot-Type Detector
- Related: Smoke Detector, Detector Spacing
A detector whose sensing element responds to conditions at a single compact location, as opposed to sampling conditions along a line or across an area.
- Detector Spacing
- Related: Spot-Type Detector, Coverage Area
The maximum permitted distance between detectors, or between a detector and a wall, established by code for a given ceiling height and detector listing.
- Coverage Area
- Related: Detector Spacing
The floor area that a single detector is credited with protecting, derived from its listed spacing and adjusted for ceiling configuration and airflow conditions.
- Rate-of-Rise Heat Detector
- Related: Fixed-Temperature Heat Detector
A heat detector that responds when surrounding temperature increases faster than a set rate, allowing it to react to a fast-growing fire before a fixed threshold is reached.
- Fixed-Temperature Heat Detector
- Related: Rate-of-Rise Heat Detector
A heat detector that operates when its sensing element reaches a predetermined temperature, regardless of how quickly that temperature was attained.
- Air Sampling Detector
- Related: Smoke Detector, Detector Spacing
A very-early-warning detection system that continuously draws air from protected areas through a pipe network to a sensitive particle sensor for analysis.
- Notification Appliance
- Related: Audible Notification Appliance, Visible Notification Appliance
An audible, visible, or tactile device that alerts occupants of a fire condition, such as a horn, speaker, strobe, chime, or bell connected to the alarm system.
- Audible Notification Appliance
- Related: Notification Appliance, Audibility
A device that produces sound to warn occupants, required to meet minimum sound pressure levels above ambient noise in the protected space.
- Visible Notification Appliance
- Related: Notification Appliance, Candela Rating
A strobe or similar light source that signals alarm to occupants who cannot hear audible devices or who are in high-noise environments.
- Candela Rating
- Related: Visible Notification Appliance
The measured luminous intensity of a visible notification appliance, used to select strobe output adequate for the size and use of the protected room.
- Audibility
- Related: Audible Notification Appliance, Voice Evacuation System
The property of an alarm signal being loud enough to be heard over ambient noise, typically expressed as sound pressure level above the background in decibels.
- Voice Evacuation System
- Related: Audibility, Notification Appliance
An emergency communication arrangement that delivers prerecorded or live spoken instructions through speakers to guide occupants during evacuation or relocation.
- Fire Alarm Control Unit (FACU)
- Related: Addressable System, Conventional System
The central panel that receives signals from initiating devices, processes them according to programmed logic, and activates notification and control outputs.
- Addressable System
- Related: Fire Alarm Control Unit (FACU), Signaling Line Circuit
A system architecture in which each initiating and output device has a unique identifier, letting the panel report the specific device that has activated.
- Conventional System
- Related: Fire Alarm Control Unit (FACU), Initiating Device Circuit
A system architecture in which devices share a circuit, so the panel reports only the zone or circuit in alarm rather than the individual device.
- Zoned System
- Related: Conventional System, Annunciator
An arrangement that groups protected areas into labeled zones so responders can locate the general area of alarm origin from the panel display.
- Annunciator
- Related: Fire Alarm Control Unit (FACU), Zoned System
A remote display panel that repeats alarm, trouble, and supervisory status information from the fire alarm control unit at a location convenient for staff or responders.
- Primary Power Supply
- Related: Secondary Power Supply, Battery Capacity Calculation
The normal commercial electrical source that operates the fire alarm system, typically a dedicated branch circuit that must not be switched or ground-fault protected in a way that disables it.
- Secondary Power Supply
- Related: Primary Power Supply, Battery Capacity Calculation
The standby source, usually rechargeable batteries or an engine generator, that keeps the fire alarm system operating when normal power fails.
- Battery Capacity Calculation
- Related: Secondary Power Supply, Primary Power Supply
The method of sizing standby batteries by summing quiescent and alarm current draws over required time periods, then applying a derating factor for aging.
- Initiating Device Circuit (IDC)
- Related: Class B Circuit, Class A Circuit
The wiring path connecting detectors, manual stations, and other initiating devices to the control unit so their alarm signals can be received.
- Signaling Line Circuit (SLC)
- Related: Addressable System, Class A Circuit
The communication loop or path used by addressable systems to carry data and power between the control unit and individually identified devices.
- Class A Circuit
- Related: Class B Circuit, Initiating Device Circuit (IDC)
A circuit arrangement in which the outgoing and return conductors are separate, so a single open fault does not prevent devices from operating.
- Class B Circuit
- Related: Class A Circuit
A circuit arrangement in which conductors run out to the devices and stop, so a single open fault disables all devices located beyond the break.
- Supervision
- Related: Trouble Signal, Class A Circuit
Continuous monitoring of circuit integrity so that opens, shorts, or ground faults produce a trouble signal at the control unit rather than silently disabling protection.
- Trouble Signal
- Related: Supervision, Annunciator
A distinct audible and visible indication at the control unit that a fault exists in the system, such as a wiring break, power loss, or device failure.
- Acceptance Test
- Related: Record of Completion, Authority Having Jurisdiction (AHJ)
The documented performance test of a completed fire alarm installation, witnessed by the authority having jurisdiction, demonstrating that all functions operate as designed.
- Record of Completion
- Related: Acceptance Test, As-Built Drawings
A form documenting the installed system configuration, device locations, and programming, signed by the installer and provided to the owner and authority having jurisdiction.
- As-Built Drawings
- Related: Record of Completion, Plan Review
Project drawings revised after installation to show the actual installed locations and routing of devices, circuits, and equipment.
- Inspection, Testing, and Maintenance (ITM)
- Related: Acceptance Test, Trouble Signal
The recurring program of visual inspection, functional testing, and servicing that keeps a fire alarm system reliable throughout its service life.
- Plan Review
- Related: As-Built Drawings, Authority Having Jurisdiction (AHJ)
The pre-construction examination of submitted fire alarm drawings and calculations by the authority having jurisdiction to verify code compliance before installation begins.
- Sequence of Operation
- Related: Plan Review, Fire Alarm Control Unit (FACU)
A written description of how the system responds to each type of input, including which outputs activate, in what order, and under what timing conditions.
- Cause-and-Effect Matrix
- Related: Sequence of Operation, Acceptance Test
A table mapping each initiating device or zone to the outputs it activates, used to document and verify programmed system logic during review and testing.