Fire safety objective
A statement in OBC Part 1 describing the goal a building must achieve, such as limiting the probability of injury to occupants from fire.
Functional statement
A Part 1 statement describing what a building or component must do to meet an objective, such as limiting the spread of fire.
Alternative solution
A design that does not follow the acceptable solutions but demonstrates compliance with the objectives and functional statements, subject to authority approval.
Group F1 occupancy
High-hazard industrial occupancy involving flammable liquids, combustible dusts, or other processes that create a high fire or explosion risk.
Building height
The number of storeys between the lowest and highest floor levels in a building, used to determine construction and fire protection requirements.
Major occupancy
The principal use or occupancy of a building or part of it, classified under OBC Part 3 as Group A, B, C, D, E, F, or G.
Fire-resistance rating
The time in minutes or hours a building component resists fire exposure while maintaining its separating or structural function under standard test conditions.
Fire separation
A construction that resists the spread of fire, which may or may not have a fire-resistance rating depending on the requirement.
Fire damper
A device installed in a duct where it penetrates a fire separation to close automatically and prevent fire spread through the duct.
Limiting distance
The horizontal distance from an exposing building face to a property line, street centre line, or adjacent building face, used for spatial separation.
Exposing building face
The exterior wall of a building that could expose an adjacent building or property to fire, evaluated for fire-resistance rating and unprotected openings.
Unprotected opening
A window, door, or other opening in an exposing building face that lacks fire protection and is counted in the permitted opening area.
Travel distance
The distance measured along the path of egress from the most remote point in a floor area to the nearest exit.
Occupant load
The number of persons for which a floor area is designed, calculated by dividing floor area by the occupant load factor for the occupancy.
Dead-end corridor
A corridor segment with only one direction of egress, limited in length because occupants could be trapped if fire blocks the single path.
Manual pull station
A fire alarm initiating device located along the egress path and at exits so occupants can manually activate the alarm system.
Fire alarm annunciator
A panel that displays the location and status of alarm, supervisory, and trouble signals to assist responders and building staff.
Smoke detector
A device that senses smoke and initiates an alarm, required in corridors serving sleeping rooms and in certain residential suites.
Standpipe system
A fixed piping system with hose connections that provides water for firefighting, classified as Class I, II, or III by intended user.
Sprinkler design density
The minimum water application rate in millimetres per minute over the design area that a sprinkler system must deliver for a given hazard.
Residential sprinkler system
A sprinkler system designed primarily for life safety in residential occupancies, typically installed under NFPA 13R with limited height and area.
Smoke control system
An engineered system using pressurization, exhaust, or both to keep egress paths tenable and limit smoke spread during a fire.
Fire command centre
A room in a high-rise building containing fire alarm annunciation, smoke control controls, and communications equipment for fire department use.
Smoke venting
A provision that releases hot smoke and gases from a space, such as an atrium or industrial area, to improve tenability and firefighting conditions.
Smoke alarm
A self-contained device that detects smoke and sounds a local alarm, required in dwelling units on each storey and near sleeping areas.
Egress window
A window in a dwelling unit sized and located to allow occupants to escape or be rescued, with specified dimensions and sill height.
Fire blocking
Construction within concealed spaces in combustible assemblies that stops the movement of fire and hot gases through the cavity.
Flammable liquid
A liquid with a flash point below 37.8 degrees Celsius, classified by flash point and boiling point for storage and handling requirements.
Combustible liquid
A liquid with a flash point at or above 37.8 degrees Celsius, subject to storage and handling rules based on its classification.
Explosion venting
A designed relief area that opens to release pressure from a deflagration to a safe outdoor location, protecting the structure and occupants.
Flash point
The lowest temperature at which a liquid gives off enough vapour to form an ignitable mixture near its surface.
Fire separation continuity
The requirement that a fire separation extend continuously through concealed spaces and intersections so that fire cannot bypass it.