OBC Large Buildings flashcards
OBC Large Buildings · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Building height definition
- The vertical distance measured from grade to the highest finished floor level of the top storey, excluding rooftop mechanical penthouses and similar projections that do not constitute storeys.
- Building area definition
- The greatest horizontal area of the building above grade, measured within the exterior faces of exterior walls and projected over the entire building footprint.
- Occupant load calculation
- The number of persons a space is designed to hold, found by dividing floor area by the occupant-load factor for the use, or by counting fixed seats.
- Exit versus exit access
- An exit is a protected continuous path from the floor area to a public way. Exit access is the unprotected portion leading from the occupied space to the exit.
- Firewall versus fire separation
- A firewall divides a building into two separate buildings for code purposes. A fire separation divides portions of one building and does not create separate buildings.
- Spatial separation measurement
- The distance from the building face to the lot line or exposing building face, used to limit unprotected openings and to set the required fire-resistance rating of exterior walls.
- Sprinkler height and area allowances
- Automatic sprinkler protection permits increased building height and area and reduced fire-resistance ratings, within the specific limits the code sets for each occupancy and construction type.
- Limit-states design principle
- Design must satisfy ultimate limit states, where factored resistance exceeds factored load effects, and serviceability limit states, which control deflection, vibration, and cracking under normal use.
- Load combination purpose
- Load combinations apply specified factors to dead, live, snow, wind, and earthquake effects so that the structure is checked for realistic worst-case concurrent loading.
- Snow drift load
- An additional snow load imposed where a roof step, parapet, or adjacent taller building traps snow, calculated from the upwind fetch and the height difference.
- Air barrier continuity
- The air barrier must form a continuous sealed plane across the envelope, including joints, penetrations, and interfaces, to control air leakage and moisture transport.
- Vapour barrier placement
- In cold climates the vapour barrier is placed on the warm side of the insulation, and its need and position depend on a moisture analysis of the assembly.
- Rain screen principle
- Envelope design controls rain by deflection at the outer surface, drainage in a cavity behind the cladding, and drying of any moisture that penetrates.
- Effective thermal resistance
- The thermal resistance of an assembly accounting for thermal bridging at framing, structural penetrations, and junctions, rather than the nominal insulation value alone.
- Lighting power density
- The maximum permitted lighting wattage per unit of floor area for a space type, used to limit energy use and often paired with automatic control requirements.
- Apparent sound transmission class
- A field-measured rating of airborne sound insulation between spaces, including flanking paths, used to set minimum separation performance between dwelling units.
- Demand control ventilation
- A control strategy that modulates outdoor air supply in response to measured occupancy, such as carbon dioxide concentration, to reduce energy use while maintaining indoor air quality.
- Assembly occupancy
- An occupancy for gatherings of people for amusement, recreation, social, religious, or similar purposes, subdivided by occupant load and by fixed or non-fixed seating.
- Institutional occupancy
- An occupancy where occupants are cared for or detained, subdivided by whether occupants can escape without assistance, which controls sprinkler and egress requirements.
- Mixed occupancy treatment
- Multiple uses in one building are either separated by fire separations and treated as distinct occupancies, or treated as one occupancy with the most restrictive requirements applied.
- Construction type limits
- Each construction type, from noncombustible to combustible, carries permitted maximum building heights and areas for each occupancy group, modified by sprinkler protection.
- Mezzanine area limit
- A mezzanine is limited in area relative to the storey below and must be open to that storey, or it is treated as a separate storey with full egress and separation.
- Travel distance to exit
- The length of the egress path measured along the route of travel from the most remote point in a space to the nearest exit, limited by occupancy and sprinkler status.
- Two means of egress
- Two separate exits are required where occupant load, travel distance, or common-path limits are exceeded, and the exits must be separated by the required distance.
- Accessible route requirement
- A continuous unobstructed path from the public way to the building entrance and to all normally occupied spaces, accessible washrooms, parking, and services.
- Guard height and openings
- Guards are required where the level difference exceeds the code threshold, with a specified minimum height and limits on openings that could permit passage of a sphere.
- High building measures
- Buildings above the code height threshold require additional life safety measures, including smoke control, stair pressurization, emergency power, and voice communication.
- Alternative solution requirement
- A proposed substitute for an acceptable solution must demonstrate equivalent performance and address every relevant objective and functional statement, supported by analysis or testing.
- Atrium smoke control
- Interconnected floor spaces and atria require smoke control analysis and systems demonstrating that smoke will not compromise egress from any occupied level.
- Building permit requirement
- A permit is required before construction, alteration, or change of use, supported by drawings and specifications sufficient to demonstrate compliance with the code.
- Field review purpose
- A designer's field review confirms that construction conforms to the sealed drawings and specifications, with deficiencies reported and resolved before occupancy.
- Occupancy authorization
- Authorization to occupy is issued after inspection confirms that required life safety systems are operational and that the building complies with the permitted documents.