CA Branch 3 study materials
CA Branch 3 study resources

CA Branch 3 cheat sheet

CA Branch 3 · Keep the key ideas within reach.

Quick reference

Laws, Regulations, and Licensing Requirements

  • California structural pest control is governed by the Structural Pest Control Act in the Business and Professions Code and by regulations in Title 16, California Code of Regulations.

  • Branch 3 covers fumigation; Branch 1 covers general pest control, and Branch 2 covers termite and wood-destroying pest work.

  • Branch 3 fumigation must be performed by or under the supervision of a licensed fumigator within a licensed structural pest control company.

  • Fumigant labels are enforceable under FIFRA and California law; use inconsistent with the label is a violation.

  • Restricted-use fumigants require the applicable licensed or certified applicator and any required permit; check county agricultural commissioner requirements.

  • Before fumigation, the licensee must give the required written notice to the owner or occupant and post warning signs at entrances, retaining copies.

  • License renewal requires continuing education and compliance with renewal deadlines; failure to renew prohibits fumigation activity.

  • Structural pest control records must be made available to the Board and county agricultural commissioner on request.

Quick reference

Fumigant Chemistry

  • Fumigant gas distribution depends on molecular weight relative to air: gases heavier than air settle in low areas, while near-air-density gases mix more evenly.

  • Methyl bromide is nonflammable and can be odorless at hazardous concentrations; chloropicrin is added as a warning agent, and its vapor is heavier than air.

  • Sulfuryl fluoride is odorless, colorless, nonflammable, and heavier than air; it is used for whole-structure insect control.

  • Aluminum and magnesium phosphide generate phosphine when exposed to atmospheric moisture; generation rate increases with humidity and temperature.

  • Phosphine is flammable and can corrode copper and brass; it may have a garlic or fish-like odor only above certain concentrations.

  • Chloropicrin is a lacrimator and respiratory irritant used as a warning agent, not as a primary structural fumigant.

  • Sorption by wood, wallboard, and contents reduces available fumigant; dosage and exposure must account for label directions and structure conditions.

  • Higher temperature generally increases vapor pressure and diffusion; lower temperature can slow volatilization and pest kill.

Quick reference

Toxicology and Label Comprehension

  • Methyl bromide is an inhalation neurotoxin and pulmonary irritant; odor is not a reliable warning because the gas can be odorless at hazardous levels.

  • Sulfuryl fluoride is an inhalation toxicant affecting the central nervous system and respiratory tract; it is odorless, so monitoring and posting are essential.

  • Phosphine causes respiratory irritation, pulmonary edema, and central nervous system effects; symptoms can be delayed for hours.

  • Chloropicrin is a strong eye and respiratory irritant that causes tearing; exposure can impair escape and requires respiratory protection.

  • The label is the primary source for signal word, PPE, reentry, clearance, target pests, sites, and maximum dosage.

  • DANGER indicates high acute toxicity; WARNING and CAUTION indicate lower hazard categories under pesticide labeling.

  • PEL is an occupational exposure limit; IDLH is immediately dangerous to life or health and requires supplied-air or SCBA.

  • Air-purifying respirators must have the correct canister for the fumigant and cannot be used at IDLH or unknown concentrations.

Quick reference

Fumigation Safety, Personal Protective Equipment, and Emergency Response

  • Never enter a fumigated structure alone; use a buddy system with communication and rescue capability.

  • Use supplied-air or SCBA for unknown concentrations, IDLH atmospheres, or concentrations above the respirator's protection factor.

  • Before entry, monitor the atmosphere with a calibrated instrument for the fumigant and for oxygen deficiency.

  • Post warning signs at every entrance, lock or secure openings, and maintain a perimeter until clearance.

  • For inhalation exposure, move the person to fresh air, call 911, and give oxygen if trained; avoid unprotected reentry.

  • For skin or eye contact, remove contaminated clothing, wash with soap and water, and flush eyes for at least 15 minutes.

  • Metal phosphide fires can release phosphine; do not use water, and use appropriate dry media while evacuating and calling emergency services.

  • The emergency plan must include evacuation routes, communication, medical contacts, and notification of authorities.

Quick reference

Fumigant Application Methods, Dosage, and Calculation

  • Volume in cubic feet equals length times width times height; for irregular spaces, sum the volumes of component areas.

  • Total fumigant equals structure volume in cubic feet divided by 1000, multiplied by the label dosage per 1000 cubic feet.

  • Convert ounces to pounds by dividing by 16; convert pounds to grams by multiplying by 454.

  • Convert cubic feet to cubic meters by multiplying by 0.0283; one cubic meter equals 35.31 cubic feet.

  • Use the label dosage table for target pest, temperature, exposure time, and structure type; do not exceed the maximum label rate.

  • Lower temperatures may require higher dosage or longer exposure because volatilization and insect activity slow.

  • Account for sorption and leakage by following label sealing requirements and monitoring concentration during exposure.

  • For phosphine, dosage is often calculated from tablet or pellet count and label tables; count and record all units used.

Quick reference

Structure Preparation, Sealing, and Tenting

  • Remove people, pets, and plants before tenting; remove or double-seal food, feed, drugs, and cosmetics unless the label permits otherwise.

  • Open interior doors, closets, cabinets, and access panels so fumigant can distribute throughout the structure.

  • Shut off ignition sources and pilot lights; disconnect or secure utilities as required by the label and company policy.

  • Seal plumbing penetrations, vents, fireplaces, and other openings; the tent must cover the entire structure.

  • Secure the tarp at the ground with sand or water snakes and inspect for tears, gaps, and loose seams before release.

  • Post warning signs at all entrances and lock or guard the perimeter to prevent unauthorized entry.

  • Clear attic and crawlspace access for monitoring and aeration; remove obstructions that block gas movement.

  • Do not allow occupants to remain in a structure that is tented or under fumigation.

Quick reference

Monitoring, Aeration, and Clearance Procedures

  • Monitor fumigant concentration at representative locations during exposure and document readings, time, and instrument used.

  • Clearance requires readings at or below the label and California reentry level before occupants may return.

  • Aeration uses fans, vents, and tarp removal to dilute and disperse fumigant; weather affects aeration speed.

  • Do not enter during aeration without appropriate respiratory protection until monitoring confirms safe levels.

  • Sample living areas, attic, crawlspace, closets, and other representative spaces, not just one central room.

  • Calibrate and check monitoring instruments before use; record calibration and any detector tube lot numbers.

  • Keep warning signs posted until clearance is complete, then remove and document.

  • If clearance readings exceed the limit, continue aeration and retest before reoccupancy.

Quick reference

Target Pest Biology and Fumigation Decision-Making

  • Fumigation is selected when pests are concealed, widespread, or deep in the structure and the label permits the site.

  • Drywood termites live in wood without soil contact and produce pellets; fumigation kills existing colonies but leaves no residual.

  • Subterranean termites require soil contact; fumigation does not prevent reinfestation, so soil treatment or barriers may be needed.

  • Bed bugs hide in cracks and crevices; fumigant must reach all harborage areas at sufficient concentration and exposure.

  • Stored-product pests in commodities may be treated with phosphine under gas-tight conditions and label directions.

  • Fumigation does not control wood decay fungi, mold, or insects that are not present at the time of treatment.

  • Inspection must identify the pest and extent before choosing fumigation; misidentification leads to treatment failure.

  • Fumigants have no residual effect; reinfestation prevention requires exclusion, wood replacement, or other tactics.

Quick reference

Recordkeeping, Notification, and Reporting

  • Record the date, time, structure volume, fumigant, lot number, dosage, temperature, exposure period, and applicator.

  • Record monitoring readings, clearance results, instrument calibration, and the time occupants were notified.

  • Keep copies of occupant notice, warning sign posting, permits, and any county agricultural commissioner reporting.

  • California pesticide use reporting requires structural applications to be reported as specified; keep copies with the job file.

  • Make records available to the Structural Pest Control Board, county agricultural commissioner, and other authorized officials.

  • Report spills, leaks, fires, and human exposures promptly to the supervisor, emergency services, and authorities as required.

  • Maintain safety data sheets and label copies for each fumigant used and train employees on their contents.

  • Retain records for the period required by California law and company policy; do not discard after clearance.