CA C-36 Plumbing flashcards
CA C-36 Plumbing · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- C-36 license scope
- A California C-36 contractor installs, repairs, and maintains plumbing systems, including DWV, water supply, fixtures, water heaters, and gas piping within license and code limits.
- Air gap backflow protection
- An air gap is the unobstructed vertical distance between a potable water outlet and the flood level rim of a receptacle; it provides the highest protection against cross-connection.
- Potable water identification
- Potable water piping must be identified and protected from contamination; nonpotable or reclaimed piping is marked purple and labeled to prevent cross-connections with drinking water.
- Local code amendments
- California local jurisdictions may adopt more restrictive plumbing amendments than the California Plumbing Code; the stricter adopted requirement governs work within that jurisdiction.
- Drainage slope rule
- Horizontal drainage pipe 2 1/2 inches and smaller slopes at least 1/4 inch per foot; pipe 3 inches and larger slopes at least 1/8 inch per foot.
- Trap arm fall limit
- A fixture trap arm must be vented within the allowed distance and must not fall more than one pipe diameter before its vent connection, preserving the trap seal.
- Fixture trap seal
- Each fixture trap must maintain a liquid seal between 2 and 4 inches deep; traps must be self-cleaning and accessible for cleaning or removal.
- Cleanout spacing
- Cleanouts are required at the base of each stack, at horizontal drainage intervals not exceeding 100 feet, and where aggregate direction changes exceed 135 degrees.
- Bathroom group DFU
- One bathroom group commonly equals 6 drainage fixture units: water closet 3, lavatory 1, and bathtub or shower 2, used for drainage sizing.
- Static pressure limit
- Code limits static water pressure at fixtures to 80 psi; a pressure-reducing valve is required where street pressure exceeds that limit, with accessible strainer and bypass.
- Pressure per foot elevation
- Water pressure changes about 0.433 psi per foot of elevation; a 10-foot rise reduces pressure by 4.33 psi, affecting fixture pressure and pipe sizing.
- Thermal expansion control
- A closed water system with a check valve or backflow preventer needs an expansion tank or listed relief device to absorb heated water expansion and protect piping.
- Water hammer arrestor
- Water hammer arrestors are installed near quick-closing valves and appliances to absorb pressure surges; they must be accessible and sized for the system.
- Water closet clearance
- A water closet needs at least 15 inches from its centerline to a side wall and 30 inches of clear width; at least 21 inches clearance is required in front.
- CalGreen fixture flow rates
- California maximums include 1.28 gallons per flush for water closets, 0.125 gallons per flush for urinals, 1.2 gallons per minute for lavatories, and 1.8 for showerheads.
- Floor drain trap primer
- A floor drain trap primer automatically adds water to the trap to maintain its seal; evaporation in unused drains can otherwise allow sewer gas into the building.
- T&P relief discharge
- A water heater temperature-and-pressure relief valve discharges through full-size pipe, without valves or traps, terminating 6 inches above the floor or outside safely.
- Seismic water heater strapping
- Water heaters require two straps: one in the upper third and one in the lower third, made of 24-gauge, 1.5-inch-wide metal, secured to framing.
- Water heater drain pan
- A water heater in a location where leakage causes damage needs a drain pan at least 1.5 inches deep with a 3/4-inch drain to an approved location.
- Expansion tank function
- A potable-water expansion tank contains a bladder that absorbs increased volume as water heats, preventing excessive pressure in a closed plumbing system.
- Sediment trap location
- A sediment trap is installed downstream of the appliance shutoff valve and as close as practical to the appliance inlet, trapping dirt before it reaches controls.
- CSST bonding requirement
- Corrugated stainless steel tubing gas piping must be bonded to the grounding electrode system with a listed bonding clamp and conductor, typically 6 AWG copper.
- Gas connector length
- A flexible appliance gas connector must not exceed 6 feet, must not be concealed, and must not pass through walls, floors, or ceilings.
- Fuel gas pressure test
- Fuel gas piping is pressure-tested before appliances connect, using the code-specified test pressure and duration; regulators and appliance valves are isolated or protected.
- Pump head calculation
- Total pump head equals static elevation change plus friction loss plus pressure head; convert psi to feet by multiplying psi by 2.31.
- Series versus parallel pumps
- Pumps in series add their heads at the same flow; pumps in parallel add their flows at the same head, so selection follows the system curve.
- Hydronic air separator
- An air separator removes entrained air from hydronic water near the boiler; air elimination protects circulators and prevents noise and corrosion.
- Architectural scale conversion
- At 1/4 inch equals 1 foot, one inch on the drawing represents 4 feet actual; multiply a measured drawing length by 48 to get actual inches.
- Slope percent conversion
- A 1/4-inch-per-foot slope equals about 2.08 percent; multiply inches per foot by 100 and divide by 12 to convert to percent.
- Trench protective system
- Cal/OSHA requires a protective system for trenches 5 feet or deeper unless a competent person determines stable rock; inspections occur before entry and as conditions change.
- Ladder setup rule
- Extension ladders are set with a 4-to-1 slope and extend at least 3 feet above the landing; they are secured and inspected before use.
- Hot work fire watch
- Soldering or other hot work requires a fire watch, removal of combustibles, and monitoring during work and for at least 30 minutes afterward.