Power Eng 1st Class study materials
Power Eng 1st Class study resources

Power Eng 1st Class cheat sheet

Power Eng 1st Class · Keep the key ideas within reach.

Quick reference

Engineering Management

  • Critical path method: the longest duration path through the network sets minimum project duration; any activity on it has zero total float.

  • Total float = LS − ES = LF − EF; a negative float indicates the schedule cannot meet the imposed completion date.

  • Earned value: CPI = EV/AC and SPI = EV/PV; CPI < 1 means cost overrun per unit of work performed.

  • Estimate at completion (typical variances) EAC = BAC/CPI; atypical variances EAC = AC + (BAC − EV).

  • Life-cycle cost analysis discounts O&M, fuel, and outage costs to present value; capital cost alone is not a valid comparison.

  • Reliability: availability = MTBF/(MTBF + MTTR); maintainability improvements reduce MTTR and raise availability without touching failure rate.

  • A management-of-change review is triggered by any modification to design, procedure, or setpoint affecting a safety-related function; the review precedes implementation.

  • Root cause analysis distinguishes physical, human, and latent (organizational) causes; correcting only the physical cause leaves recurrence likely.

Quick reference

Codes, Standards and Regulatory Compliance

  • ASME BPVC Section I governs power boilers; Section VIII Division 1 governs unfired pressure vessels; Section II covers materials, Section IX welding and brazing qualifications.

  • Maximum allowable working pressure derives from the longitudinal shell formula: t = PR/(SE − 0.6P) + corrosion allowance, with S from Section II Part D at design temperature.

  • A hydrostatic test is conducted at 1.5 times MAWP (Section I) with the test pressure held and no permanent deformation accepted as the pass criterion.

  • ASME Section IX qualifies procedures (WPS/PQR) and performance (WPQ); a change in essential variables requires requalification.

  • National Board NBIC covers in-service inspection, repair, and alteration; an R-stamp holder performs repairs and an AI authorizes return to service.

  • Jurisdictional authority: the state or provincial boiler code adopts the ASME code by reference and sets inspection intervals and operator licensing.

  • Code cases and interpretations are not retroactive unless the jurisdiction adopts them; the edition in force at installation governs unless otherwise directed.

  • Safety valve capacity must equal or exceed maximum generating capacity; the set pressure may not exceed MAWP and the accumulation limit (typically 10%) applies.

Quick reference

Applied Thermodynamics

  • Rankine cycle efficiency = (Wturbine − Wpump)/Qin; regenerative feedwater heating raises mean temperature of heat addition and improves cycle efficiency.

  • Reheat to the original steam temperature increases work output without exceeding throttle temperature limits; double reheat adds a smaller further gain.

  • Carnot efficiency = 1 − Tc/Th; no real cycle between the same reservoirs can exceed it.

  • Isentropic efficiency of a turbine = actual enthalpy drop / isentropic enthalpy drop; moisture above roughly 12% at exhaust erodes last-stage blades.

  • Supercritical steam (above 22.06 MPa, 374 °C critical point) has no latent heat of vaporization; once-through design replaces the drum.

  • First law for steady flow: q − w = Δh + Δke + Δpe; second law fixes the maximum work and identifies irreversibility as entropy generation.

  • Heat rate = 3600/thermal efficiency (kJ/kWh basis); a 40% efficient unit uses about 9,000 kJ/kWh.

  • Throttle conditions and condenser pressure dominate output; a 1 kPa rise in back pressure typically costs on the order of 1% of output.

Quick reference

Heat Transfer and Fluid Mechanics

  • Fourier's law: q = −kA dT/dx; convection q = hAΔT; radiation q = εσA(Ts⁴ − Tsur⁴).

  • Overall heat transfer coefficient U combines conduction and convection resistances: 1/UA = 1/hiAi + Rwall + 1/hoAo.

  • Log mean temperature difference LMTD = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2) for counterflow and parallel flow exchangers.

  • Reynolds number Re = ρVD/μ; transition near 2,300 in pipe flow, turbulent above roughly 4,000.

  • Darcy-Weisbach head loss hf = f(L/D)(V²/2g); friction factor rises with roughness and falls with Reynolds number in turbulent flow.

  • NPSH available = (Patm − Pv)/(ρg) + static head − friction losses; NPSH required must be lower or cavitation occurs.

  • Bernoulli with losses: P1/ρg + V1²/2g + z1 = P2/ρg + V2²/2g + z2 + hL.

  • Dittus-Boelter: Nu = 0.023 Re^0.8 Pr^n, n = 0.4 for heating and 0.3 for cooling of the fluid.

Quick reference

Boiler Design, Construction, Materials and Pressure-Part Integrity

  • Drum material is typically SA-516 Gr 70 carbon steel; superheater and reheater tubing uses SA-213 T91 or TP347H for creep strength at high metal temperature.

  • Creep becomes design-limiting above roughly 400 °C for carbon steel; the Larson-Miller parameter correlates stress, temperature, and rupture time.

  • Corrosion fatigue and thermal fatigue crack at attachments and header ligaments; fatigue life is consumed by start-stop and load-change cycles.

  • Waterwall tube failures commonly trace to short-term overheat (restricted flow), long-term overheat (scale), or hydrogen damage from low-pH corrosion.

  • Post-weld heat treatment relieves residual stress; Section I mandates it above specified thicknesses and for certain alloys.

  • Dissimilar metal welds (ferritic to austenitic) require nickel-based filler (e.g., ERNiCr-3) to accommodate differential thermal expansion.

  • Boiler drum level and drum internals design must accommodate swell and shrinkage during load changes; false level indication is a known trip cause.

  • Fitness-for-service (API 579/ASME FFS-1) evaluates flaws against remaining strength rather than requiring immediate repair.

Quick reference

Boiler Operation

  • Drum level is maintained by a three-element control using steam flow, feedwater flow, and drum level; single-element control is used at low load.

  • Furnace purge before ignition is mandatory: typically five air changes at not less than 25% of full-load airflow to clear combustible gases.

  • Loss of flame, loss of all flame scanners, or loss of forced draft trips the fuel supply; a master fuel trip is the final protective action.

  • Cold start warming rate limits thermal stress in the drum; the drum-to-fluid temperature difference and saturation temperature ramp are the controlling variables.

  • Sootblower operation reduces gas-side fouling and restores heat transfer; blowing during high load with stable combustion avoids tube damage.

  • Boiler trip and interlock testing is performed before each startup; bypassing a protective device requires documented management authorization.

  • Carryover control depends on drum internals, steam purity, and dissolved solids; silica volatility limits steam-side deposition in turbines.

  • A drum level low-low trip protects against waterwall starvation; a high-high trip protects against carryover and turbine water induction.

Quick reference

Combustion, Fuels and Emissions Control

  • Stoichiometric air for natural gas is about 17.2 mass units per unit fuel; for coal it is roughly 11 to 12; excess O2 of 2–3% dry is typical for gas firing.

  • The three T's - temperature, turbulence, and time - govern complete combustion; CO rises when any is deficient.

  • NOx control: low-NOx burners, overfire air, flue gas recirculation, and selective catalytic reduction with ammonia or urea reagent.

  • SCR operates near 300–400 °C with a vanadium-titania catalyst; ammonia slip and catalyst poisoning by sulfur and arsenic are key limits.

  • SO2 control via wet limestone flue gas desulfurization achieves over 95% removal; the by-product is gypsum.

  • Particulate control: electrostatic precipitator efficiency depends on resistivity and specific collection area; fabric filters rely on a conditioned filter cake.

  • Combustion efficiency losses: dry flue gas, moisture in fuel and air, and unburned carbon; stack loss dominates and rises with excess air.

  • Mercury control uses activated carbon injection or co-benefit capture from SCR plus wet FGD; coal chlorine content affects speciation.

Quick reference

Prime Movers: Steam and Gas Turbines, Engines and Generators

  • Steam turbine stage types: impulse (pressure drop across nozzles only) and reaction (pressure drop across both fixed and moving blades).

  • Turbine governor control: droop (typically 4–5%) defines the speed or load change for a frequency deviation; isochronous control holds constant speed.

  • Overspeed trip is set at 110% of rated speed, independent of the main governor, with a separate mechanical or electronic trip device.

  • Gas turbine Brayton cycle efficiency rises with pressure ratio and firing temperature; simple cycle is about 35–40%, combined cycle above 60%.

  • Combined cycle HRSG recovers exhaust heat; duct firing raises output but lowers overall efficiency relative to unfired operation.

  • Generator synchronization requires matching voltage, frequency, phase sequence, and phase angle before breaker closure.

  • Reverse power protection prevents a generator from motoring; loss-of-excitation and negative-sequence relays protect the rotor.

  • Steam turbine water induction causes thermal shock and rotor bowing; drain systems and turbine drains must be verified before rolling.

Quick reference

Auxiliary Systems, Pumps, Compressors, Piping and Valves

  • Centrifugal pump affinity laws: flow ∝ N, head ∝ N², power ∝ N³; throttling wastes energy compared with variable speed control.

  • Pump operating point is the intersection of the pump curve and the system curve; running two pumps in parallel adds flow, in series adds head.

  • Best efficiency point (BEP) operation minimizes radial thrust and vibration; sustained operation far from BEP shortens bearing and seal life.

  • Positive displacement pumps deliver near-constant flow against varying pressure and require a relief valve on the discharge.

  • Compressor surge is reversed flow at low flow/high pressure ratio; anti-surge control recycles flow to keep the operating point off the surge line.

  • Safety valve vs relief valve: a safety valve opens fully and pops; a relief valve opens proportionally; a pilot-operated valve uses system pressure to actuate.

  • Piping expansion loops and hangers absorb thermal growth; a cold spring is installed to offset thermal movement at operating temperature.

  • Check valve selection affects water hammer; a nonslam or damped check valve limits surge on pump trip.

Quick reference

Instrumentation, Controls, Protection Systems and Data Monitoring

  • A control loop is proportional-integral-derivative; proportional action leaves offset, integral removes it, derivative anticipates and amplifies noise.

  • Loop tuning: increase gain until oscillation, then back off; Ziegler-Nichols open-loop uses the process reaction curve (dead time, time constant, gain).

  • A distributed control system separates controllers from the human-machine interface; a safety instrumented system is independent of the DCS for protective functions.

  • Safety integrity level (SIL) is assigned from risk graph or LOPA; SIL 3 requires a probability of failure on demand between 10⁻³ and 10⁻⁴.

  • Redundant transmitters with voting (2-out-of-3) reduce spurious trips while preserving detection of a failed sensor.

  • A thermocouple and an RTD differ in principle: thermocouples generate a small voltage from dissimilar metals; RTDs change resistance with temperature.

  • Calibration traceability requires a documented chain to a national standard; as-found and as-left data are recorded for each instrument.

  • Alarm rationalization reduces nuisance alarms; the operator response time must exceed the alarm flood interval for the alarm to be meaningful.

Quick reference

Electrical Systems, Power Distribution and Plant Utilities

  • Motor starting current for a squirrel-cage induction motor is typically 5–7 times full-load current at direct-on-line start.

  • A generator breaker must be rated for the system fault level; interrupting rating must exceed the calculated short-circuit current.

  • Ground fault protection limits damage and touch potential; high-resistance grounding limits fault current while allowing continued operation.

  • Power factor correction capacitors reduce line current and losses; overcorrection causes leading power factor and possible overvoltage.

  • Transformer loading: oil-filled units are rated with a top-oil rise and hot-spot limit; loading beyond nameplate shortens insulation life.

  • Uninterruptible power supply and battery systems support controls and emergency loads; battery capacity is rated in ampere-hours at a specified discharge rate.

  • Station service and emergency diesel generators must be tested under load; a start-and-run test without load does not prove capacity.

  • Arc flash hazard analysis defines incident energy and boundary; energized work requires a permit and appropriate personal protective equipment.

Quick reference

Water Treatment, Corrosion Control and Environmental Protection

  • Boiler feedwater: oxygen removal by deaeration to ppb levels plus chemical scavenging with hydrazine, carbohydrazide, or DEHA.

  • Scale control uses phosphate or coordinated phosphate/pH treatment; caustic embrittlement (stress corrosion cracking) is avoided by keeping caustic concentration controlled.

  • Corrosion control: maintain pH in the range 8.5–10.5 for carbon steel feedwater; copper alloys need lower pH and ammonia limits.

  • Conductivity and cation conductivity indicate dissolved solids and ionic contamination; cation conductivity is more sensitive to chloride and sulfate.

  • Cooling water treatment uses biocides, scale inhibitors, and corrosion inhibitors; cycles of concentration are limited by the least soluble salt.

  • Condensate polishing removes corrosion products and ionic impurities; a rise in cation conductivity signals a condenser tube leak.

  • Effluent limits cover thermal discharge, pH, metals, and biocides; the Clean Water Act NPDES permit sets the enforceable limits.

  • Ash handling and landfill leachate are regulated separately from air emissions; coal combustion residual rules govern storage and disposal.

Quick reference

Plant Safety, Risk Management, Incident Investigation and Emergency Response

  • Hazard analysis methods: HAZOP for process deviations, FMEA for component failure modes, and LOPA for independent protection layer counting.

  • Risk = likelihood × consequence; ALARP requires risk to be reduced as low as reasonably practicable, with documented justification for residual risk.

  • Permit-to-work and lockout/tagout isolate energy sources; verification of zero energy is required before work begins.

  • Confined space entry requires atmospheric testing for oxygen, flammables, and toxics, plus a rescue plan and attendant.

  • Incident investigation: preserve evidence, interview witnesses separately, and distinguish immediate causes from root and latent causes.

  • Emergency response for a boiler or turbine trip: verify fuel shutoff, maintain auxiliary power, and follow the written emergency procedure rather than improvising.

  • Hot work near combustible dust or gas requires a gas test and a fire watch with a defined post-work monitoring period.

  • Management of change, pre-startup safety review, and operating procedures are the process-safety pillars that prevent repeat incidents.