Power Eng 3rd Class study materials
Power Eng 3rd Class study resources

Power Eng 3rd Class cheat sheet

Power Eng 3rd Class · Keep the key ideas within reach.

Quick reference

Applied Thermodynamics and Heat Transfer

  • Sensible heat: Q = m·cp·ΔT; latent heat uses enthalpy of vaporization/condensation instead of cp.

  • Steam tables give saturation temperature/pressure pairs; superheated steam needs both pressure and temperature to fix state.

  • First Law for steady flow: q − w = Δh + ΔKE + ΔPE (per unit mass); for a boiler w = 0, so q ≈ Δh.

  • Thermal efficiency of a Rankine cycle = (h1 − h2) − (h4 − h3) divided by (h1 − h4), using pump and turbine enthalpies.

  • Conduction: Q = k·A·ΔT/L; convection: Q = h·A·ΔT; radiation: Q = ε·σ·A·(T1⁴ − T2⁴) with T in kelvin.

  • Overall heat-transfer coefficient U combines series resistances: 1/UA = 1/(hA) inside + wall resistance + 1/(hA) outside.

  • LMTD = (ΔT1 − ΔT2)/ln(ΔT1/ΔT2); use it with Q = U·A·LMTD for heat exchangers.

  • Entropy increases in any real (irreversible) process; isentropic efficiency compares actual to ideal work.

  • Absolute pressure = gauge pressure + atmospheric pressure; vacuum readings are subtracted from atmospheric.

Quick reference

Boilers and Combustion Systems

  • Theoretical (stoichiometric) air is the minimum O2 needed for complete combustion; excess air = (actual air − theoretical)/theoretical × 100%.

  • Typical excess-air targets: ~15% for gas/oil, ~20–30% for coal; too little gives CO and smoke, too much wastes heat up the stack.

  • Combustion products: C + O2 → CO2; 2H2 + O2 → 2H2O; incomplete combustion yields CO, so CO in flue gas signals air deficiency.

  • Drum water level must be maintained near normal water level (NWL); low water can expose tubes and cause overheating and failure.

  • Safety valve setting must not exceed the boiler's maximum allowable working pressure (MAWP); it protects against overpressure.

  • Blowdown removes dissolved solids and sludge; bottom blowdown also removes sediment, surface (continuous) blowdown controls dissolved solids.

  • A boiler's evaporative capacity is expressed as kg/h of steam; equivalent evaporation normalizes to 100 °C feedwater at 100 °C.

  • Draft is measured in pascals or mm of water column; balanced draft keeps furnace slightly negative.

Quick reference

Boiler Auxiliaries

  • Forced-draft fan supplies combustion air; induced-draft fan pulls flue gas out and maintains furnace negative pressure.

  • Air preheater recovers stack heat to warm combustion air, raising boiler efficiency by lowering exit gas temperature.

  • Economizer heats feedwater using flue gas; it lowers stack loss but must stay above acid dew point to avoid corrosion.

  • Superheater raises steam temperature above saturation; attemperation (spray) controls final steam temperature.

  • Sootblowers remove ash/fouling from tube surfaces; fouling raises gas-side resistance and reduces heat transfer.

  • Steam traps remove condensate while holding back steam; failed-open traps waste steam, failed-closed traps cause water hammer.

  • Deaerator removes dissolved O2 and CO2 by heating water to saturation and venting; it also serves as feedwater storage.

  • Ash-handling and dust-collection systems (baghouse, ESP) control particulate emissions; ESP efficiency depends on resistivity and field strength.

Quick reference

Piping, Valves

  • Gate valves are for on/off isolation with low pressure drop; globe valves are for throttling and give higher pressure drop.

  • Check valves allow flow in one direction only and prevent backflow; they are not used for throttling.

  • Safety (relief) valves open at set pressure; they must be tested and sealed, never used as a control valve.

  • Steam traps and drain valves must be installed at low points and before valves to remove condensate and avoid water hammer.

  • Pipe expansion is handled by loops, bends, or expansion joints; anchors and guides direct movement and prevent stress.

  • Water hammer results from rapid valve closure or trapped condensate; prevention is slow closing and proper drainage.

  • Pressure ratings of flanges and fittings drop as temperature rises; select by design pressure and temperature together.

  • A pressure-reducing valve maintains downstream pressure; a bypass and safety valve downstream are commonly required.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump head-capacity curve slopes down; operating point is where the pump curve meets the system curve.

  • Cavitation occurs when local pressure falls below vapor pressure; NPSH available must exceed NPSH required.

  • Affinity laws: flow ∝ speed, head ∝ speed², power ∝ speed³ for a given impeller.

  • Positive-displacement pumps deliver nearly constant flow regardless of pressure; a relief valve is required on the discharge.

  • Reciprocating compressors are positive displacement; centrifugal compressors suit large flows at high volume.

  • Turbine efficiency = actual work / isentropic work; steam turbines use enthalpy drop across stages.

  • Pump power ≈ (ρ·g·Q·H)/efficiency; compressors use polytropic or isentropic power relations.

  • Vibration, high bearing temperature, and abnormal noise signal misalignment, imbalance, or bearing wear.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A control loop has a sensor/transmitter, controller, and final control element; the controller compares measurement to setpoint.

  • PID control: proportional responds to error, integral eliminates offset, derivative anticipates rate of change.

  • Low-water fuel cutoff (LWCO) shuts off fuel on low drum level; it must be tested regularly and is a critical safety device.

  • Flame scanners (flame safeguards) prove main flame and pilot; loss of flame signal must trip fuel within the trial-for-ignition time.

  • Pressure and temperature transmitters output 4–20 mA; 4 mA is live zero so a broken wire is detectable.

  • Safety interlocks trip the burner on high pressure, low water, low fuel pressure, or loss of combustion air.

  • A deadweight tester calibrates pressure gauges; gauges should be checked against a known standard.

  • Boiler trips and alarms must be annunciated; bypassing a safety device requires formal authorization and documentation.

Quick reference

Electrical Systems and Power Distribution

  • Ohm's law: V = I·R; power: P = V·I = I²·R for DC and resistive AC loads.

  • Three-phase power = √3·V_L·I_L·power factor; power factor correction reduces reactive current and line losses.

  • Motor full-load current rises with load; overload relays protect motors from sustained overcurrent.

  • Circuit breakers and fuses protect against short circuit and overload; earthing/grounding protects personnel.

  • Lockout/tagout (LOTO) isolates energy sources before maintenance; verify zero energy before work.

  • Motor starters (DOL, star-delta, VFD) control starting current; VFDs vary frequency to control speed.

  • Insulation resistance testing (megger) checks winding insulation; low readings indicate moisture or degradation.

  • Standby generators and emergency power must be tested under load; automatic transfer switches switch between sources.

Quick reference

Water Treatment and Steam/Water Chemistry

  • Scale forms from hardness (Ca, Mg) salts; softening or demineralization removes scale-forming ions.

  • Dissolved oxygen causes pitting corrosion; deaeration plus oxygen scavenger (e.g., sulfite) controls it.

  • pH control: boiler water typically alkaline (around 10–11) to limit corrosion; too high promotes caustic embrittlement.

  • Conductivity or TDS indicates dissolved solids; continuous blowdown controls them to prevent carryover.

  • Silica can carry over into steam and deposit on turbine blades; limit silica in boiler water.

  • Phosphate treatment precipitates hardness as sludge, removed by blowdown.

  • Condensate return should be monitored for corrosion products and contamination; returning clean condensate saves energy.

  • Chemical dosing must match load and water quality; over-dosing or under-dosing both cause problems.

Quick reference

Refrigeration, HVAC, and Auxiliary Systems

  • Refrigeration cycle: compressor raises pressure, condenser rejects heat, expansion valve drops pressure, evaporator absorbs heat.

  • COP = refrigeration effect / work input; higher COP means more efficient cooling.

  • Superheat at evaporator outlet protects the compressor from liquid slugging; subcooling at condenser outlet improves capacity.

  • Refrigerant pressure–temperature relationship: saturation pressure corresponds to evaporating or condensing temperature.

  • Chillers use chilled water or direct expansion; cooling towers reject condenser heat to atmosphere.

  • HVAC comfort depends on dry-bulb temperature, humidity, and air movement; psychrometrics relates them.

  • Air handling units use filters, coils, and fans; dirty filters reduce airflow and increase energy use.

  • Compressor high discharge pressure often indicates fouled condenser or non-condensable gases.

Quick reference

Codes, Regulations, and Safety

  • Boiler and pressure-vessel codes set design, materials, welding, inspection, and stamping requirements; follow the applicable code edition.

  • Periodic inspection and hydrostatic testing verify integrity; records must be retained and available.

  • Safety valves must be set, sealed, and tested per code; tampering is prohibited.

  • Confined-space entry requires permit, atmospheric testing, ventilation, attendant, and rescue plan.

  • Hot-work permits control welding/cutting near flammables; fire watch and extinguisher required.

  • Lockout/tagout and energy isolation are mandatory before maintenance on rotating or electrical equipment.

  • Operators must hold the required certification/qualification for the boiler class and plant.

  • Report accidents and near misses; statutory notifications apply to serious incidents.

Quick reference

Plant Operations, Maintenance, and Administration

  • Preventive maintenance schedules reduce unplanned outages; lubrication, alignment, and inspection are core tasks.

  • Log readings (pressure, temperature, level, flow) at defined intervals to trend performance and detect drift.

  • Startup sequence typically includes checks, purge, pilot light-off, main flame, and gradual load increase.

  • Shutdown sequence: reduce load, stop fuel, purge, and maintain water level during cooldown.

  • Root-cause analysis (5 Whys, fishbone) identifies underlying causes of failures rather than symptoms.

  • Spare-parts and consumables inventory must match critical equipment; critical spares avoid long downtime.

  • Shift handover should document abnormal conditions, ongoing work, and outstanding permits.

  • Energy efficiency monitoring compares actual fuel/steam ratio to baseline; deviations trigger investigation.

Quick reference

Pumps, Compressors, and Prime Movers (Prime Movers)

  • Steam turbine stages: impulse (pressure drop across nozzles) and reaction (pressure drop across moving blades).

  • Turbine overspeed trip protects against loss of load; it must be tested regularly.

  • Condenser vacuum improves turbine efficiency by lowering exhaust pressure and increasing enthalpy drop.

  • Gas turbine efficiency rises with firing temperature and pressure ratio; compressor fouling reduces output.

  • Diesel engines: compression ignition; power depends on fuel rate and air supply; turbocharging increases output.

  • Governor controls prime-mover speed by adjusting fuel/steam input to match load.

  • Alignment of prime mover to driven equipment prevents vibration and coupling wear.

  • Cooling and lubrication of bearings are essential; high temperature indicates inadequate flow or wear.

Quick reference

Instrumentation, Controls, and Safety Devices (Additional Devices)

  • Pressure gauges must be selected for the range; a gauge should read near mid-scale at normal operating pressure.

  • Thermocouples and RTDs measure temperature; RTDs are more accurate at low temperatures, thermocouples suit high temperatures.

  • Flow measurement: orifice plate uses differential pressure; accuracy depends on straight pipe runs and tapping.

  • Level measurement: differential pressure, float, or radar; density changes affect DP level accuracy.

  • Control valves fail-safe position (fail-open or fail-closed) is chosen based on process safety.

  • Alarm and trip setpoints must be below mechanical limits and above normal operating range.

  • Calibration records and traceability are required for safety-critical instruments.

  • Interlock testing before startup confirms trips function; document results.

Quick reference

Electrical Systems and Power Distribution (Motors and Protection)

  • Motor nameplate gives voltage, current, power factor, speed, and insulation class; operate within ratings.

  • Star-delta starting reduces starting current but also reduces starting torque.

  • VFDs control motor speed and can cause harmonics; filters and proper grounding mitigate issues.

  • Earth fault protection detects leakage current to ground; residual current devices protect personnel.

  • Cable sizing considers current-carrying capacity and voltage drop; long runs need larger conductors.

  • Batteries and UPS support critical controls during power loss; test capacity periodically.

  • Arc-flash hazards require PPE and safe work procedures; de-energize before opening panels.

  • Phase imbalance and single-phasing damage motors; protection relays detect them.

Quick reference

Water Treatment and Steam/Water Chemistry (Condensate and Feedwater)

  • Feedwater temperature affects boiler efficiency; economizer and deaerator raise it.

  • Condensate polishing removes corrosion products and dissolved solids for high-pressure boilers.

  • Amine dosing raises condensate pH to protect return lines from carbonic acid corrosion.

  • Chloride and sulfate limits protect against stress-corrosion cracking in high-pressure boilers.

  • Blowdown rate is set by allowable dissolved solids; automatic blowdown uses conductivity control.

  • Sampling points must be representative; cool samples before testing.

  • Iron and copper in feedwater indicate corrosion; investigate source.

  • Chemical storage and handling require labeling, secondary containment, and PPE.

Quick reference

Refrigeration, HVAC, and Auxiliary Systems (Auxiliaries)

  • Cooling tower approach = leaving water temperature minus wet-bulb temperature; lower approach means better performance.

  • Chiller efficiency expressed as kW per ton of refrigeration; lower is better.

  • Air filters classified by MERV; higher MERV captures finer particles but increases pressure drop.

  • Duct static pressure controls fan speed in variable-air-volume systems.

  • Steam and hot-water heating coils require traps and vents to remove air and condensate.

  • Compressor oil management: oil separators and proper charge prevent oil logging and wear.

  • Refrigerant leak detection protects personnel and environment; some refrigerants are asphyxiants.

  • Economizer cooling uses outside air when conditions allow, reducing mechanical cooling.

Quick reference

Codes, Regulations, and Safety (Permits and Procedures)

  • Permit-to-work systems control high-risk tasks; permits specify hazards and controls.

  • Isolation certificates confirm equipment is de-energized and drained before maintenance.

  • Emergency response plans cover fire, leak, and evacuation; drills verify readiness.

  • Personal protective equipment selection follows hazard assessment (heat, chemical, electrical).

  • Noise and heat stress are occupational hazards requiring monitoring and controls.

  • Environmental limits on emissions (NOx, SOx, particulate) require monitoring and reporting.

  • Waste and effluent disposal must follow regulations; record manifests.

  • Management of change (MOC) reviews modifications before implementation.

Quick reference

Plant Operations, Maintenance, and Administration (Performance)

  • Boiler efficiency can be estimated by direct method (heat output/heat input) or indirect (losses) method.

  • Stack loss is the largest boiler loss; it rises with excess air and exit gas temperature.

  • Heat rate = fuel energy input / useful output; lower heat rate means better efficiency.

  • Performance tests require steady load and calibrated instruments.

  • Trending vibration and temperature predicts failures before breakdown.

  • Work orders should record cause, action, and parts used for history.

  • Training and competency records support safe operation and audits.

  • Energy audits identify savings from insulation, traps, and combustion tuning.

Quick reference

Pumps, Compressors, and Prime Movers (Compressors)

  • Compressor volumetric efficiency falls as clearance volume and pressure ratio increase.

  • Intercooling between stages reduces work and improves efficiency.

  • Surge in centrifugal compressors is reversed flow at low flow; anti-surge control recycles flow.

  • Compressor discharge temperature rises with pressure ratio; cooling and lubrication control it.

  • Air dryers remove moisture; dew point depends on dryer type.

  • Reciprocating compressor valves and rings wear; monitor pressure and temperature.

  • Compressor efficiency compares actual power to ideal isentropic power.

  • Safety valves and relief devices protect compressors and receivers from overpressure.

Quick reference

Instrumentation, Controls, and Safety Devices (Control Valves)

  • Control valve flow characteristic: linear, equal-percentage, quick-opening; equal-percentage suits wide range.

  • Valve sizing uses Cv, which relates flow to pressure drop and specific gravity.

  • Cavitation in liquid control valves causes noise and damage; avoid by limiting pressure drop.

  • Positioners improve valve response and accuracy.

  • Actuator air failure position must be defined for safety.

  • Valve stroke testing verifies travel and calibration.

  • Stiction causes poor control; regular maintenance prevents it.

  • Bypass valves allow maintenance without shutdown; use with care.

Quick reference

Electrical Systems and Power Distribution (Generation)

  • Generator output depends on excitation (voltage) and prime-mover input (frequency/load).

  • Synchronization requires matching voltage, frequency, and phase before paralleling.

  • Load sharing between generators is controlled by governor droop settings.

  • Protective relays (overcurrent, differential, reverse power) isolate faults.

  • Earthing of generator neutral limits fault current.

  • Excitation systems control reactive power and voltage.

  • Black-start capability allows restart without grid power.

  • Regular testing of generators and switchgear ensures reliability.

Quick reference

Water Treatment and Steam/Water Chemistry (Boiler Water Limits)

  • Total dissolved solids limits depend on boiler pressure; higher pressure requires lower TDS.

  • Alkalinity control prevents foaming and caustic attack.

  • Hardness in boiler water indicates softener breakthrough; act promptly.

  • Dissolved oxygen limits are tight for high-pressure boilers.

  • Iron and copper limits protect against deposition.

  • Silica limits depend on pressure and turbine requirements.

  • pH and conductivity are routine tests; log results.

  • Chemical feed rates should be adjusted to test results, not fixed.

Quick reference

Refrigeration, HVAC, and Auxiliary Systems (Steam and Condensate)

  • Steam traps: thermodynamic, thermostatic, and mechanical types; select by application.

  • Flash steam forms when high-pressure condensate drops in pressure; recover it.

  • Condensate receivers and pumps return condensate to the deaerator.

  • Steam headers need drains at low points and before valves.

  • Insulation reduces heat loss and protects personnel.

  • Air in steam systems reduces heat transfer; vents remove it.

  • Water hammer from condensate must be prevented by proper trapping and drainage.

  • Steam quality (dryness) affects turbines and processes.

Quick reference

Codes, Regulations, and Safety (Pressure Equipment)

  • Pressure-relief device sizing uses required capacity and set pressure.

  • Inspection intervals are set by code and service conditions.

  • Repairs to pressure parts require qualified welders and procedures.

  • Records of inspections and repairs must be kept.

  • Non-destructive testing (radiography, ultrasonic, dye penetrant) verifies integrity.

  • Hydrostatic test pressure is typically a multiple of design pressure per code.

  • Operators must not alter safety devices or setpoints.

  • Incident reporting and investigation are required.

Quick reference

Plant Operations, Maintenance, and Administration (Reliability)

  • Condition monitoring: vibration, oil analysis, thermography.

  • Planned maintenance reduces reactive work.

  • Failure modes and effects analysis (FMEA) prioritizes risks.

  • Criticality ranking guides spare parts and inspection.

  • Root-cause analysis prevents recurrence.

  • Contractor management requires induction and supervision.

  • Documentation and drawings must be current.

  • Continuous improvement uses performance data.

Quick reference

Applied Thermodynamics and Heat Transfer (Psychrometrics)

  • Dry-bulb temperature measures sensible heat; wet-bulb reflects evaporative cooling.

  • Relative humidity = actual vapor pressure / saturation vapor pressure.

  • Dew point is the temperature at which condensation begins.

  • Enthalpy of moist air includes sensible and latent components.

  • Humidification and dehumidification change moisture content.

  • Cooling coils condense water when below dew point.

  • Psychrometric charts relate dry-bulb, wet-bulb, humidity, and enthalpy.

  • Comfort depends on temperature, humidity, and air movement.

Quick reference

Boilers and Combustion Systems (Fuels and Burners)

  • Fuel properties: calorific value, density, viscosity, sulfur, ash.

  • Burners atomize liquid fuel for complete combustion.

  • Air-fuel ratio control maintains efficient combustion.

  • Flame stability depends on burner design and fuel quality.

  • Ignition systems and pilots must be proven.

  • Furnace dimensions affect residence time and combustion.

  • Fuel oil heating reduces viscosity for atomization.

  • Gas fuel requires pressure regulation and leak detection.

Quick reference

Boiler Auxiliaries (Fans and Draft)

  • Fan laws: flow ∝ speed, pressure ∝ speed², power ∝ speed³.

  • Dampers and inlet vanes control flow; VFDs save energy.

  • Fan balance and alignment prevent vibration.

  • Bearing temperature and lubrication are monitored.

  • Draft losses occur in ducts, air preheater, and economizer.

  • Balanced draft maintains slight negative furnace pressure.

  • Fan surge/stall occurs at low flow; avoid.

  • Air leakage reduces efficiency.

Quick reference

Piping, Valves (Steam Traps)

  • Thermostatic traps respond to temperature; mechanical traps to density.

  • Failed-open traps waste steam; failed-closed traps flood.

  • Trap testing by sound, temperature, or ultrasonic.

  • Strainers protect traps from debris.

  • Bypass around traps aids maintenance.

  • Condensate quality affects trap selection.

  • Group trapping can hide failures.

  • Regular trap surveys save energy.

Quick reference

Pumps, Compressors, and Prime Movers (Bearings)

  • Journal bearings support radial loads; thrust bearings axial loads.

  • Oil film separates surfaces in hydrodynamic bearings.

  • Bearing temperature rise indicates inadequate lubrication or overload.

  • Vibration analysis detects bearing defects.

  • Alignment reduces bearing load.

  • Grease and oil selection depends on speed and temperature.

  • Contamination accelerates wear; filter oil.

  • Condition monitoring extends bearing life.

Quick reference

Instrumentation, Controls, and Safety Devices (Burner Management)

  • Burner management system (BMS) sequences purge, light-off, and shutdown.

  • Pre-purge removes unburned fuel before ignition.

  • Trial-for-ignition time limits unburned fuel if no flame.

  • Flame failure response must trip fuel.

  • Interlocks prevent unsafe operation.

  • Regular testing of BMS is required.

  • Documentation of setpoints and tests.

  • Bypassing BMS is prohibited without authorization.

Quick reference

Electrical Systems and Power Distribution (Safety)

  • Electrical isolation and LOTO before work.

  • Test for zero energy before touching conductors.

  • Use insulated tools and PPE.

  • Arc-flash boundaries must be respected.

  • Grounding protects against fault current.

  • Overcurrent protection sized to conductors.

  • Regular inspection of panels and cables.

  • Report electrical incidents.