Power Eng 4th Class 4A study materials
Power Eng 4th Class 4A study resources

Power Eng 4th Class 4A cheat sheet

Power Eng 4th Class 4A · Keep the key ideas within reach.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.

Quick reference

Applied Thermodynamics and Mechanics

  • Sensible heat: Q = m·c·ΔT; latent heat of vaporization of water at atmospheric pressure ≈ 2257 kJ/kg.

  • Superheat = actual steam temperature minus saturation temperature at the same absolute pressure.

  • Thermal efficiency of a Rankine cycle = (h1 − h2)/(h1 − hf); turbine work minus pump work divided by heat added.

  • Steam tables: enthalpy of saturated liquid hf, saturated vapor hg, latent heat hfg = hg − hf; hfg falls to zero at critical point (22.06 MPa, 374 °C).

  • First law for steady flow: Q − W = m·(h2 − h1 + (V2² − V1²)/2 + g(z2 − z1)); kinetic and potential terms often negligible.

  • Stress = force ÷ cross-sectional area; strain = change in length ÷ original length; Young's modulus = stress ÷ strain in the elastic range.

  • Thermal expansion: ΔL = α·L·ΔT; a 100 m steel pipe (α ≈ 12×10⁻⁶/°C) grows about 12 mm per 10 °C rise.

  • Boiler horsepower = 33 475 kJ/h ≈ 9.81 kW; 1 kW = 1 kJ/s; 1 bar = 100 kPa = 0.1 MPa.

Quick reference

Boilers and Boiler Systems

  • Heating surface is measured on the fire side; economizer and superheater surface are included, but waterwall tubes are counted by their exposed fire-side area.

  • Factor of evaporation = (h_steam − h_feedwater) ÷ 2257 kJ/kg; equivalent evaporation = actual evaporation × factor.

  • Boiler efficiency (indirect/heat loss method): 100% − stack loss − moisture loss − unburned carbon loss − radiation and convection loss.

  • Safety valve set pressures: the lowest-set valve is at or below MAWP; no valve may be set above MAWP, and the highest set pressure is typically ≤ 110% of MAWP.

  • Superheater and reheater outlet safety valves are set lower than drum safety valves so the superheater valves open first.

  • Water column and gauge glass must be blown down and proven; low-water fuel cutoff must be tested at each shift and after repairs.

  • A firetube boiler has products of combustion inside tubes surrounded by water; a watertube boiler has water in tubes surrounded by hot gas.

  • Steam drum internals: baffles and separators remove moisture; carryover causes high conductivity in the steam and superheater fouling.

Quick reference

Boiler Auxiliaries and Combustion Equipment

  • Stoichiometric air for natural gas ≈ 9.5 m³ air/m³ gas (about 2 m³ per 1000 kJ); for fuel oil ≈ 14 kg air/kg oil.

  • Optimum excess air for natural gas ≈ 5–10%; for oil ≈ 10–15%; for coal ≈ 15–25%. Excess O₂ in flue gas ≈ 3% corresponds to roughly 15% excess air.

  • Draft: natural draft = stack height × (air density − gas density) × g; forced draft fans supply air, induced draft fans remove gas.

  • Flame scanners must prove flame within the trial-for-ignition period; typical pilot trial for ignition ≤ 10 s for gas, ≤ 15 s for oil.

  • Furnace purge: airflow at ≥ 25% of full-load airflow for at least 5 minutes before any ignition attempt.

  • Air-fuel ratio control on a jackshaft or parallel positioning system must be tuned with a flue gas analyzer at low, mid, and high fire.

  • Soot blowers reduce stack temperature by cleaning convection surfaces; a rising stack temperature at fixed load signals fouling.

  • Pulverizer fineness typically 70–80% passing a 200-mesh sieve; primary air transports coal and controls mill outlet temperature.

Quick reference

Pumps, Compressors, and Prime Movers

  • Centrifugal pump affinity laws: Q ∝ N, H ∝ N², P ∝ N³; Q ∝ D, H ∝ D², P ∝ D³.

  • NPSH available = (p_suction − p_vapour)/(ρ·g) + static head − friction loss; NPSH required comes from the pump curve.

  • Best efficiency point (BEP): operate between 70% and 120% of BEP flow to avoid recirculation, cavitation, and shaft deflection.

  • Specific speed Ns = N·√Q ÷ H^0.75; low Ns favors radial impellers, high Ns favors mixed-flow and axial designs.

  • Positive displacement pumps deliver nearly constant flow against varying pressure; a relief valve on the discharge is mandatory.

  • Reciprocating compressor: clearance volume reduces volumetric efficiency; multi-stage with intercooling reduces power and discharge temperature.

  • Steam turbine stage efficiency improves with superheat; condensers lower exhaust pressure and increase available enthalpy drop.

  • Diesel engine starting: pre-lube, barring, and air start pressure typically 1.7–3 MPa; overspeed trip tested before running.

Quick reference

Piping, Valves, and Fittings

  • ASME B31.1 is the Power Piping Code; B31.3 covers process piping; B16.5 covers pipe flanges and flanged fittings.

  • Pipe schedule number = 1000 × P/S, where P is internal design pressure and S is allowable stress; higher schedule = thicker wall.

  • Gate valves are for isolation, globe valves for throttling, and check valves permit flow in one direction only.

  • Safety valve: pop action with huddling chamber; relief valve: gradual opening proportional to overpressure; pilot-operated valves use system pressure to actuate.

  • Blowdown valves are installed between the boiler and the safety valve; the safety valve must never be used as a blowdown or isolating valve.

  • Steam traps: thermostatic (temperature), thermodynamic (velocity/pressure), and float-and-thermostatic (condensate level); trap failure causes water hammer.

  • Expansion loops and anchors absorb thermal growth; guides allow axial movement and prevent buckling.

  • Flange bolting is tightened in a star pattern in stages to compress the gasket evenly and avoid leakage.

Quick reference

Instrumentation, Controls, and Safety Devices

  • A transmitter outputs 4–20 mA DC over its calibrated span; 4 mA is live zero so a broken wire reads below zero and is detectable.

  • PID control: proportional output = Kp·error; integral removes offset; derivative anticipates rate of change and amplifies noise.

  • Three-element drum level control uses drum level, steam flow, and feedwater flow to reject false level readings from swell and shrink.

  • Low-water fuel cutoff must be wired to lock out the burner and require manual reset; it is not a substitute for the gauge glass.

  • Flame safeguard program: prepurge, pilot trial for ignition, main flame trial, run period, and post-purge; any failure goes to lockout.

  • High steam pressure and high water temperature limit switches must be independent of the operating controller and tested periodically.

  • Calibration: zero and span adjustment against a traceable standard; record as-found and as-left values.

  • Thermocouples (mV output) and RTDs (resistance change) are common temperature sensors; RTDs are more stable and accurate at low temperatures.

Quick reference

Water Treatment and Boiler Feedwater

  • Scale is mainly calcium and magnesium salts; hardness is removed by softening (ion exchange) or demineralization.

  • Internal treatment: phosphate or chelant for scale control, sulfite or hydrazine for oxygen scavenging, amines for condensate pH control.

  • Oxygen pitting is prevented by deaeration plus chemical scavenger; sulfite residual typically 20–40 mg/L in the boiler water.

  • Blowdown controls dissolved solids: conductivity is the usual indicator; maintain within the boiler manufacturer's limit.

  • pH target for boiler water is typically 10.5–11.5; condensate pH 8.5–9.5 to protect carbon steel return lines.

  • Foaming and carryover are caused by high alkalinity, high dissolved solids, or oil contamination; silica can carry over into steam and deposit on turbine blades.

  • Caustic embrittlement (stress corrosion cracking) occurs in riveted or stressed areas at high caustic concentration; nitrate or coordinated phosphate treatment mitigates it.

  • Feedwater heaters raise efficiency by bleeding extraction steam; they also remove some dissolved gases.

Quick reference

Fuels, Combustion, and Environmental Controls

  • Combustion requires fuel, oxygen, heat, and an ignition source; the three T's are time, temperature, and turbulence.

  • Higher heating value (HHV) includes latent heat of water vapour; lower heating value (LHV) excludes it; natural gas HHV ≈ 37–39 MJ/m³.

  • Flue gas CO₂ and O₂ are inversely related; rising O₂ with falling CO₂ indicates excess air.

  • NOx control: low-NOx burners, flue gas recirculation, overfire air, and selective catalytic reduction (SCR) with ammonia or urea.

  • Particulate control: mechanical collectors, fabric filters (baghouses), and electrostatic precipitators; ESP efficiency depends on resistivity and field strength.

  • SO₂ control: wet limestone scrubbers, spray dryers, and dry sorbent injection.

  • Opacity monitors measure visible emissions; a sudden rise often indicates incomplete combustion or soot blowing.

  • Fuel oil viscosity must be reduced by heating for atomization; natural gas is measured by volume corrected to standard conditions.

Quick reference

Electrical Fundamentals and Plant Services

  • Ohm's law: V = I·R; power P = V·I = I²R = V²/R; single-phase kW = V·I·pf ÷ 1000.

  • Three-phase power: kW = √3·V·I·pf ÷ 1000; apparent power kVA = √3·V·I ÷ 1000.

  • Motor synchronous speed = 120·f ÷ poles; a 4-pole motor on 60 Hz runs at 1800 rpm, with slip typically 2–4%.

  • Motor protection: overload heaters or electronic overloads, short-circuit fuses or breakers, and ground-fault protection.

  • Locked-rotor current is typically 5–8 times full-load current; reduced-voltage starters limit inrush.

  • Transformer: voltage ratio equals turns ratio; current ratio is inverse; kVA rating is set by winding temperature rise.

  • Emergency generator and battery systems supply control power, lube oil pumps, and emergency lighting on loss of normal supply.

  • Grounding: equipment bonding protects personnel; a ground fault on an ungrounded system is detected by a ground detector, not by tripping.

Quick reference

Safety, Codes, and Regulations

  • ASME Boiler and Pressure Vessel Code Section I covers power boilers; Section IV covers heating boilers; Section VIII covers pressure vessels.

  • ASME Section VI covers care and operation of heating boilers; Section VII covers care and operation of power boilers.

  • Jurisdictional inspection: internal and external inspections at intervals set by the authority having jurisdiction; certificates of inspection are posted.

  • Confined space entry requires permit, atmospheric testing (O₂ 19.5–23.5%, LEL below 10%, H₂S and CO below limits), attendant, and rescue plan.

  • Lockout/tagout: isolate energy, apply lock and tag, verify zero energy before work; only the person who applied the lock removes it.

  • Hot work permit requires fire watch, combustible clearance, and gas testing before and during welding or cutting.

  • Boiler room ventilation must supply combustion air and limit ambient temperature; gas-fired burners need permanent openings sized to the appliance input.

  • Incident reporting: any explosion, rupture, or serious injury is reported to the authority having jurisdiction immediately; records of operator training and log entries are retained.