Red Seal Agricultural Equipment Technician flashcards
Red Seal Agricultural Equipment Technician · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Lockout tagout verification
- After isolating and locking all energy sources, the technician must attempt a start or test for zero energy to confirm isolation before beginning repair work.
- ROPS with seat belt
- A rollover protective structure only protects the operator when the seat belt is fastened, keeping the body inside the protected zone during a rollover.
- Hydraulic accumulator precharge
- Nitrogen precharge is typically set at one-half to two-thirds of minimum working pressure. Oil at the gas valve means the bladder or piston has failed.
- Confined space atmospheric limits
- Entry requires oxygen between 19.5 and 23.5 percent, plus testing for hydrogen sulfide, carbon monoxide, and flammable gas before and during entry.
- Torque-to-yield fasteners
- These fasteners are tightened to a torque plus a specified angle and stretch permanently, so they must be replaced rather than reused.
- Cylinder bore taper measurement
- Use a telescoping gauge and outside micrometer at top, middle, and bottom in two axes ninety degrees apart to detect taper and out-of-round.
- Bearing press fit rule
- Press force is applied only to the interference-fit race: the inner race when fitting to a shaft, the outer race when fitting into a housing.
- Series versus parallel circuits
- In series, current is common and voltages add. In parallel, voltage is common, currents add, and total resistance is below the smallest branch.
- CAN bus resistance check
- With power off, resistance across CAN high and low should read about 60 ohms from two parallel 120 ohm terminators; 120 ohms means one terminator is open.
- Voltage drop testing under load
- Measure voltage drop with the circuit energized and loaded; more than about 0.5 volts on a 12 volt path indicates excessive resistance in cable or connection.
- Parasitic draw threshold
- After modules sleep, a healthy machine draws under roughly 50 milliamps; a higher reading points to a stuck relay, module, or accessory.
- Hydraulic horsepower formula
- Hydraulic horsepower equals flow in gallons per minute multiplied by pressure in psi, divided by 1714. One gpm at 1000 psi is about 0.58 hp.
- Cylinder force calculation
- Force equals pressure times piston area. Retraction force uses bore area minus rod area, so retraction is faster and weaker than extension.
- Aeration versus cavitation
- Aeration produces foamy, spongy oil from air ingress. Cavitation is a knocking noise from vapor pockets caused by a restricted inlet or cold oil.
- Load-sensing hydraulic systems
- The pump varies displacement to hold a fixed pressure margin above load pressure, reducing energy use and heat at low demand.
- Gear ratio torque effect
- Ratio equals driven teeth divided by driving teeth. A 3:1 reduction triples output torque while dividing output speed by three.
- PTO standard speeds
- Standard PTO speeds are 540 rpm at 540 engine rpm and 1000 rpm at 1000 engine rpm on older tractors; economy modes reach rated PTO speed at lower engine rpm.
- Driveline universal joint phasing
- On a two-joint shaft, yokes must be in phase and joint angles at each end equal, otherwise vibration and rapid joint wear result.
- Front axle tire lead
- Mechanical front-wheel-drive tractors run front tires about 1 to 5 percent faster than the rear to aid steering; wrong sizes cause driveline windup.
- Diesel compression ratio range
- Diesel engines typically run 14:1 to 23:1 compression. Low cranking compression from worn rings or valves causes hard starting and poor power.
- Valve lash clearance effects
- Too little clearance holds valves off their seats and burns them; too much causes noise and reduced lift. Set to specification hot or cold as stated.
- DPF regeneration temperature
- Diesel particulate filter regeneration needs exhaust temperatures above roughly 550 degrees Celsius; excessive idling and short cycles load the filter and cause derate.
- Superheat and subcooling
- Superheat is evaporator outlet temperature minus evaporating temperature, typically 5 to 10 degrees Celsius. Subcooling indicates charge and condenser condition.
- Refrigerant recovery requirement
- Refrigerant must be recovered, never vented. Evacuate below 500 microns and hold vacuum to confirm no leaks before charging.
- Seeding rate calibration
- Rate equals seed count per hectare times thousand kernel weight, adjusted for germination and purity; verify by catching seed over a measured distance.
- Plant population from row counts
- Population per hectare equals plants per meter of row divided by row spacing in meters; confirm with a field count after emergence.
- Combine total loss target
- Acceptable total harvest loss is typically near 1 percent of yield, split between separator loss behind the machine and cleaning shoe loss.
- Forage harvester length of cut
- Theoretical length of cut depends on feedroll speed relative to cutterhead speed; shorter chop packs better but raises power demand.
- Sprayer calibration formula
- Gallons per acre equals gallons per minute per nozzle times 5940, divided by speed in mph times nozzle spacing in inches.
- Nozzle flow versus pressure
- Nozzle flow varies with the square root of pressure, so doubling pressure increases flow only about 41 percent, making pressure poor rate control.
- RTK correction loss
- RTK accuracy depends on a radio or cellular correction link; losing correction degrades guidance to autonomous accuracy within minutes, so monitor correction age.
- ISOBUS plug and play
- ISO 11783 lets displays, controllers, and implements interoperate; confirm the task controller and section control functions are enabled for variable rate work.