Hearing conservation threshold
An 8-hour exposure at or above 85 dBA requires a hearing conservation program; each 3 dB increase halves the permitted exposure time.
Respirable crystalline silica
Dust from cutting concrete or tile; wet cutting or dust extraction plus an N95 respirator is required, and the OSHA PEL is 50 µg/m³ as an 8-hour TWA.
Asbestos in flooring
Pre-1990 vinyl sheet, vinyl asbestos tile, and mastic may contain asbestos; test before sanding or demolition and stop work if suspect material is disturbed.
Ladder angle rule
Set ladders at a 4:1 angle, maintain three-point contact, and never stand on the top two rungs; fall protection is required at 3 m in construction.
Calcium chloride test
Measures moisture vapor emission rate in lb/1000 ft²/24 h from a concrete slab; it is not the same as an in-situ relative humidity probe.
Trowel notch and coverage
A 1/16 in square notch spreads about 30-35 ft²/gal, while a 1/4 in × 3/8 in notch spreads about 60-70 ft²/gal for large-format tile.
Power stretcher
Reaches the 1-2 % stretch required for most carpet; a knee kicker is for positioning and stairs only and cannot achieve the required tension.
Adhesive open time
The window after spreading before the adhesive skins over; adhesive that has skinned must be removed and re-spread, not wetted.
Subfloor flatness tolerance
The standard is 3 mm in 3 m (1/8 in in 10 ft) for most resilient and tile products, checked with a 3 m straightedge.
Concrete cure period
Standard concrete needs 28 days before moisture testing; lightweight or fast-track concrete needs manufacturer-specific testing before covering.
3-4-5 squaring method
A triangle with sides in a 3:4:5 ratio establishes a right angle; use it to set centerlines and verify border widths at opposite walls.
Tile deflection requirement
Ceramic tile requires L/360 or stiffer and stone requires L/720; check joist span tables before installing stone.
Perimeter expansion gap
Leave 6-10 mm (1/4-3/8 in) at walls and at every 6-9 m in large fields for tile and laminate; cover with baseboard or shoe molding.
In-situ RH probe
Measures relative humidity inside a concrete slab; typical limits are 75-80 % for resilient and 65 % for wood products.
Uncoupling membrane
Isolates tile from slab movement; a crack-isolation membrane bridges existing cracks up to about 3 mm (1/8 in) wide.
Thin-set selection
Modified thin-set for plywood and most tile, unmodified for some large-format porcelain over membranes, and epoxy for food service and chemical exposure.
Primer purpose
Applied to porous or dusty slabs before patching or adhesive; without it the adhesive may fail or flash off too fast.
Heat-welded vinyl seam
Standard for commercial sheet vinyl; residential and some vinyl composition tile use a chemical weld or seam sealer instead.
VCT quarter-turn pattern
A basket-weave layout for vinyl composition tile; the pattern must be established before spreading adhesive so the field stays aligned.
LVP floating installation
Click-system luxury vinyl plank is not glued down; it needs a 6-10 mm expansion gap at walls and a level subfloor.
Roller weight for sheet goods
A 100 lb roller passes over the field and seams after sheet vinyl installation to remove trapped air and set the adhesive.
Tackless strip placement
Pins angle toward the wall, with a gap equal to the carpet thickness plus about 6 mm (1/4 in) from the wall.
Carpet seam placement
Cut seams along the carpet grain and place them away from high-traffic areas and out of direct light to reduce visible wear.
Carpet tile pattern
Installed in a quarter-turn or monolithic pattern with consistent direction, then rolled with a 75-100 lb roller.
Carpet pad selection
Use a pad rated for the carpet and traffic; a pad that is too thick or too soft shortens carpet life and voids some warranties.
Hardwood acclimation
Solid hardwood typically needs 3-7 days in the room at 18-24 °C and 35-55 % RH; engineered and laminate may need 24-48 hours.
Blind nailing hardwood
Fasteners go through the tongue at a 45° angle, spaced about 200-300 mm (8-12 in) and closer at board ends.
Wood moisture content match
Wood subfloor moisture content should be within 2-4 % of the flooring; concrete slabs need a vapor barrier and a moisture test.
Laminate end-joint stagger
Floating laminate planks are clicked together and staggered at least 200 mm (8 in) at end joints to distribute load.
Thin-set slake time
Mix to the manufacturer's water ratio, let it slake for 10 minutes, then remix; pot life is typically 2-4 hours.
Mortar coverage minimum
Achieve at least 80 % mortar coverage in dry areas and 95 % in wet areas; back-butter large-format tile.
Tile lippage limits
Allowable lippage is typically 1 mm (1/32 in) for stone and 1.5 mm (1/16 in) for ceramic, measured with a straightedge.
Grout curing and sealing
Do not grout until thin-set has cured, typically 24 hours; seal grout after it cures, typically 72 hours, with a penetrating sealer.
Transition molding fastening
Reducers, T-moldings, and thresholds must be fastened to the subfloor, not through the floating floor, at floor height changes.