Fixture unit (FU)
A unit expressing the probable demand of a fixture on the water supply; about 1 FU equals 1 gpm, and fixture units are summed to size supply piping.
Developed length
The total pipe length along the longest run from the water source to the farthest fixture, including an allowance for fittings and valves; used to size supply pipe.
Trap arm length limit
The distance from a fixture trap to its vent; it is limited by pipe size, for example about 5 ft for 1-1/4 in and 8 ft for 2 in pipe.
Hydrostatic water test
A pressure test of the water distribution system, typically at 100 psi for 60 minutes with no pressure drop, performed before the piping is concealed.
Drainage air test
A test of the DWV system using air at about 5 psi for 15 minutes, an alternative to the water test used when water is impractical.
Air gap backflow protection
The unobstructed vertical distance between a supply outlet and the flood-level rim of a receiving vessel; it provides the highest level of cross-connection protection.
T&P relief valve
A temperature and pressure relief valve on a water heater that opens at a set limit; its discharge must terminate safely, usually within 6 in of the floor.
Thermal expansion tank
A tank installed on a closed water system to absorb the volume increase caused by heating, preventing excessive pressure and relief valve discharge.
Combustion air openings
Two permanent openings, one high and one low, that supply air to a confined space containing a fuel-burning appliance; each is sized by the appliance input.
Drain cable sizing
Matching a drain cleaning cable to pipe diameter: 5/16 in for 1-1/4 to 2 in lines, 3/8 in for 2 to 3 in, and 1/2 in for 3 to 4 in.
Stack vent
The continuation of a soil or waste stack above the highest fixture connection, which vents the stack to the outdoors above the roof.
Water closet spacing
Minimum clearances for a water closet: at least 15 in from centerline to a side wall and 30 in between adjacent fixture centerlines.
Lead-free definition
A material containing not more than 0.25 percent weighted average lead in its wetted surfaces, required for potable water pipe, solder, and flux.
Building drain
The lowest horizontal piping of a drainage system, which receives soil and waste from the stacks and conveys it to the building sewer.
Drainage fixture unit
A unit expressing the probable flow a fixture adds to the drainage system; a water closet is 4 DFU private and a lavatory is 1 DFU.
Trap seal depth
The vertical depth of water retained in a fixture trap, normally 2 to 4 in, which blocks sewer gas from entering the building.
Cleanout location
A fitting giving access to a drain for clearing blockages, required at the base of each stack, at the building sewer, and at intervals along long horizontal runs.
Water hammer arrestor
A device installed near a quick-closing valve to absorb the pressure surge caused by sudden flow stoppage, preventing noise and pipe damage.
Total dynamic head
The sum of static lift, friction loss, and required discharge pressure that a pump must overcome; it is used to select a pump from its curve.
Pressure-reducing valve
A valve that lowers incoming water pressure to a set downstream value, commonly 50 to 60 psi, protecting fixtures and piping from excessive pressure.
Dielectric union
A fitting installed between dissimilar metals, such as copper and steel, to break electrical contact and prevent galvanic corrosion at the joint.
PEX expansion fitting
A connection method in which the pipe end is expanded and a fitting inserted; the pipe shrinks back to create a seal, rated for potable water.
RPZ assembly
A reduced-pressure zone backflow preventer used for high-hazard connections; it has two check valves and a relief valve and is tested annually.
Disinfection of water lines
Treating new or repaired potable water piping with a chlorine solution and then flushing it before use to kill bacteria introduced during work.
Legionella control
Managing hot water systems by keeping storage at about 140°F, circulating the water, and avoiding dead legs and stagnant piping.
Water closet rough-in
The distance from the finished wall to the center of the closet flange, commonly 12 in for a standard toilet; it must match the fixture before the flange is set.
Vent height above fixture
A vent must rise at least 6 in above the flood-level rim of the highest served fixture before it offsets horizontally.
Water service sizing
Selecting the service pipe from the total fixture-unit demand and the available pressure so the farthest fixture still receives adequate flowing pressure.
Recirculation loop
A hot water return loop that keeps hot water near fixtures, reducing wait time, but it increases energy use and must be insulated and controlled.
Tankless sizing
Selecting a tankless water heater by the peak flow rate and the temperature rise required, since it heats water instantly and cannot store a reserve.
Backwater valve
A valve on the building sewer that closes to prevent sewage from the public main from backing up into the building; it must be accessible for maintenance.
Septic tank sizing
Determining tank volume from the number of bedrooms or daily flow, commonly about 1,000 to 1,500 gallons for a single-family dwelling.