Refrigeration COP

The useful cooling rate divided by the energy-input rate for a clearly stated system boundary and set of operating conditions.

Superheat

The difference between actual vapour temperature and the appropriate local saturation temperature at the same pressure, using the correct refrigerant reference.

Subcooling

The difference by which a liquid temperature is below the appropriate saturation reference at its pressure, interpreted with the correct product data.

Absolute pressure

Pressure referenced to an ideal vacuum, obtained from a positive gauge reading by adding the relevant local atmospheric pressure.

Volumetric efficiency

A comparison of admitted or delivered suction-volume flow with geometric displacement, using compatible reference conditions for the specified compressor calculation.

Liquid slugging

An abnormal entry of liquid into a vapour compressor that can create damaging forces because liquid is much less compressible than vapour.

Net oil pressure

The useful oil-delivery pressure differential evaluated against the relevant opposing compressor pressure rather than using the gallery indication alone.

Surge

An unstable operating phenomenon in a dynamic compressor associated with flow and pressure conditions outside the appropriate stable operating range.

Approach temperature

A specifically defined temperature difference between process streams or a stream and refrigerant reference, used with flow and load information to assess performance.

Dew point

The temperature at which a given moist-air state begins to condense water when cooled at the relevant pressure without changing its moisture content beforehand.

Cascade system

A refrigeration arrangement with separate circuits coupled thermally through an intermediate heat exchanger, rather than one common mixed refrigerant inventory.

Secondary coolant

A fluid that carries heat between the load and a primary refrigeration heat exchanger, selected for its thermal, hydraulic, and protection requirements.

Deadband

A range between control switching thresholds in which the output state may depend on the preceding operation, preventing an assumption from one temperature alone.

Interlock

A control condition that must be satisfied for an operation to be allowed or continued, according to the designed sequence and protection requirements.

External equalizer

A pressure-reference connection used by an appropriate expansion valve to account for the relevant evaporator-outlet pressure in its control force balance.

Calibration

An established relationship between an instrument indication and a reference quantity, documented so measurement accuracy and any required correction can be assessed.

Emergency response plan

The facility-specific arrangement of responsibilities, communication, protective actions, evacuation, and competent response for identified abnormal or hazardous situations.

Verified isolation

A controlled process addressing the relevant energy and material sources and checking the required safe condition before maintenance or other exposed work.

Atmospheric clearance

The required competent verification and authorization that an affected space is suitable for the intended entry, not merely an absence of odor.

Pressure relief

A protective function that limits specified overpressure conditions through an approved device and discharge arrangement, rather than serving as routine temperature regulation.

Temperature glide

The range of saturation temperatures across phase change for a zeotropic blend at a specified pressure, requiring appropriate dew or bubble references.

Fractionation

A change in blend proportions that can occur because components partition differently between phases during leakage or handling under particular conditions.

Operating log

A time-linked record of actual plant readings, states, alarms, observations, and actions that supports trend analysis, handover, and accountable follow-up.

Performance boundary

The defined set of plant components and energy transfers included in a performance calculation, necessary for consistent interpretation and comparison of results.