Cardiac Anatomy and Physiology

  • Normal left ventricular wall thickness is 6-10 mm in diastole and the right ventricular free wall is normally under 5 mm; walls are measured at the chordal level, perpendicular to the long axis.

  • Coronary supply: the LAD perfuses the anterior wall, anteroseptum, and apex; the RCA perfuses the right ventricle, inferior wall, and inferior septum; the circumflex perfuses the lateral wall.

  • Cardiac cycle order: isovolumic contraction, rapid ejection, reduced ejection, isovolumic relaxation, rapid filling, diastasis, atrial systole.

  • The first heart sound is mitral and tricuspid closure; the second heart sound is aortic and pulmonic closure.

  • Normal stroke volume is 60-100 mL, cardiac output 4-8 L/min, and cardiac index 2.5-4.0 L/min/m2; cardiac output equals heart rate times stroke volume.

  • The right atrium receives the superior vena cava, inferior vena cava, and coronary sinus; the left atrium receives four pulmonary veins (right and left superior and inferior).

  • The normal aortic valve area is 3-4 cm2 and the valve has three cusps named right coronary, left coronary, and non-coronary.

  • Resting right atrial pressure is about 3-8 mmHg and normal right ventricular systolic pressure is roughly 15-30 mmHg; normal pericardial fluid volume is 15-50 mL.

Quick reference

Ultrasound Physics and Instrumentation

  • Propagation speed in soft tissue is assumed to be 1540 m/s; wavelength in millimeters equals 1540 divided by the frequency in MHz.

  • Higher transmitted frequency produces a shorter wavelength, better axial resolution, greater attenuation, and less penetration.

  • Axial resolution equals spatial pulse length divided by two; it improves with fewer cycles per pulse and with higher frequency.

  • Lateral resolution is determined by beam width and improves with higher frequency, a larger aperture, and focusing at the depth of interest.

  • Attenuation in soft tissue is approximately 0.5 dB/cm/MHz; time-gain compensation corrects for depth-dependent loss of echo amplitude.

  • The Nyquist limit is pulse repetition frequency divided by two; aliasing occurs when the Doppler shift exceeds it and is corrected by raising PRF, lowering the baseline, shifting to a higher scale, or using continuous wave Doppler.

  • Doppler shift equals (2 x transmitted frequency x velocity x cosine of the angle) divided by 1540; a 60-degree angle underestimates velocity by 50 percent.

  • Frame rate equals pulse repetition frequency divided by lines per frame, so a narrower sector and shallower depth increase temporal resolution.

  • Mechanical index relates to cavitation and thermal index relates to heating; under ALARA keep MI at or below 1.9 and TI at or below 6.0 for general cardiac imaging.

Quick reference

Echocardiographic Imaging Techniques, Views, and Protocols

  • Parasternal long axis displays the right ventricular outflow tract, aortic root, left ventricle, mitral valve, left atrium, and descending aorta; LV dimensions are measured at the chordal level.

  • Apical 4-chamber at roughly 0 degrees shows all four chambers and both atrioventricular valves; anterior angulation to about 10 degrees adds the LVOT and aortic valve in the 5-chamber view.

  • Apical 2-chamber shows the anterior and inferior walls; apical 3-chamber (long axis) shows the anteroseptum, inferolateral wall, LVOT, and aortic valve.

  • Subcostal imaging is the best window for the inferior vena cava, right atrium, and abdominal aorta and is the fallback when parasternal and apical windows are poor.

  • The suprasternal notch view images the aortic arch, its three branches, and the proximal descending thoracic aorta.

  • Chamber sizes and wall thickness are measured at end-diastole (QRS onset); LV volumes and ejection fraction use biplane Simpson method of disks at end-diastole and end-systole.

  • TEE midesophageal angles: 4-chamber about 0 degrees, 2-chamber about 90 degrees, long axis about 120 degrees, and transgastric mid short axis about 45 degrees.

  • For evaluating valvular regurgitant jets the color Doppler Nyquist limit is typically set at 50-70 cm/s.

Quick reference

Acquired and Congenital Cardiac Pathology

  • Severe aortic stenosis: peak velocity at least 4 m/s, mean gradient at least 40 mmHg, valve area 1.0 cm2 or less, and dimensionless index below 0.25.

  • Severe mitral regurgitation: vena contracta at least 0.7 cm, effective regurgitant orifice at least 0.4 cm2, regurgitant volume at least 60 mL, and systolic flow reversal in pulmonary veins.

  • Severe mitral stenosis: valve area 1.0 cm2 or less, mean gradient at least 10 mmHg, pressure half-time at least 220 ms; rheumatic disease is the most common cause.

  • Hypertrophic cardiomyopathy: asymmetric septal hypertrophy, systolic anterior motion of the mitral leaflet, and a late-peaking dagger-shaped LVOT Doppler signal; obstruction is a gradient of 30 mmHg or more.

  • Cardiac amyloidosis: biventricular wall thickening, granular sparkling texture, apical-sparing longitudinal strain, and low ECG voltages relative to wall thickness.

  • Cardiac tamponade: moderate to large effusion, right atrial systolic collapse, right ventricular diastolic collapse, inferior vena cava plethora, and more than 25 percent respiratory variation in mitral inflow.

  • Constrictive pericarditis: pericardial thickening, septal bounce, annulus reversus with medial e-prime greater than lateral e-prime, and more than 25 percent respiratory variation in mitral inflow.

  • Bicuspid aortic valve is the most common congenital cardiac anomaly; ventricular septal defect is the most common defect diagnosed at birth; tetralogy of Fallot combines VSD, overriding aorta, RVOT obstruction, and right ventricular hypertrophy.

Quick reference

Hemodynamics, Doppler, and Quantitative Assessment

  • Modified Bernoulli equation: pressure gradient equals 4 times the square of peak velocity; RVSP equals 4 times the square of peak TR velocity plus right atrial pressure.

  • Continuity equation: aortic valve area equals (0.785 x LVOT diameter squared x LVOT VTI) divided by aortic valve VTI; LVOT diameter is measured inner edge to inner edge in mid-systole.

  • Stroke volume equals LVOT cross-sectional area times LVOT velocity-time integral; a normal LVOT VTI is approximately 18-22 cm.

  • PISA method: effective regurgitant orifice area equals (2 pi x radius squared x aliasing velocity) divided by peak regurgitant velocity; regurgitant volume equals EROA times the regurgitant jet VTI.

  • Mitral valve area by pressure half-time equals 220 divided by PHT in milliseconds; a PHT of 220 ms corresponds to an area of 1.0 cm2.

  • dP/dt from the mitral regurgitation jet equals 32 divided by the time in seconds between the 1 m/s and 3 m/s crossings.

  • Diastolic function: septal e-prime at least 7 cm/s, lateral e-prime at least 10 cm/s, E/e-prime below 8 normal, above 14 elevated filling pressure, and E/A ratio 1-1.5 with deceleration time 160-240 ms.

  • Keep the Doppler angle at or below 20 degrees; the detected shift falls with the cosine of the angle, so a 60-degree intercept records only half the true velocity.

Quick reference

Patient Care, Safety, and Professional Standards

  • ALARA means using the lowest mechanical and thermal indices and the shortest dwell time that still yield diagnostic information.

  • For general cardiac imaging keep mechanical index at or below 1.9 and thermal index at or below 6.0; stricter limits apply to ophthalmic and fetal exposures.

  • TEE requires fasting of roughly 6-8 hours, informed consent, sedation, and monitoring; contraindications include esophageal stricture, esophageal varices, and recent gastrointestinal surgery.

  • TEE probes contact mucous membranes and are semi-critical devices requiring high-level disinfection after every patient; external cardiac probes require low-level disinfection.

  • Ultrasound contrast agents are contraindicated in known hypersensitivity to perflutren and in patients with intracardiac shunts.

  • Standard precautions, hand hygiene, and cleaning of transducers and ECG leads reduce nosocomial transmission between patients.

  • Electrical safety includes inspecting cables and connectors, verifying proper grounding, and monitoring patient leakage current and transducer temperature.

  • Professional standards require patient privacy, informed consent for invasive or contrast procedures, and accurate documentation of measurements, findings, and limitations of the study.