CEM flashcards
CEM · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Scope 2 emissions
- Indirect greenhouse gas emissions from purchased electricity, steam, heat, or cooling. Reported using location-based (grid average) or market-based (contractual instruments such as RECs) methods.
- Renewable portfolio standard
- A policy requiring load-serving entities to supply a minimum percentage of electricity from qualifying renewable sources, typically verified through tradable renewable energy credits.
- ASHRAE 90.1
- The commercial building energy standard covering envelope, lighting, HVAC, and service water. Jurisdictions adopt specific editions; compliance can be prescriptive, trade-off, or performance based.
- Lighting power density
- Allowable installed lighting watts per square foot by space type under energy codes. Interior LPD plus allowances for decorative, display, and exterior lighting determine compliance.
- Billing demand
- The kW value used to compute the demand charge, usually the highest 15- or 30-minute interval in the billing period, sometimes subject to a ratchet based on prior peaks.
- Load factor
- Average load divided by peak load over a period: kWh / (peak kW x hours). A low load factor signals demand-charge reduction potential.
- Power factor correction
- Adding capacitors to reduce reactive power. Required kVAR = kW x (tan(acos PF1) - tan(acos PF2)); avoid leading power factor at light load and harmonic resonance.
- ASHRAE Level 2 audit
- An energy survey and analysis that breaks down end-use consumption, evaluates measures with cost and savings estimates, and supports capital planning.
- Pitot tube airflow
- Velocity in ft/min equals 4005 times the square root of velocity pressure in inches of water column. Used with duct area to compute volumetric flow.
- Combustion excess air
- Air supplied beyond stoichiometric requirement. Measured via flue O2 or CO2; too little risks CO and smoke, too much wastes fuel up the stack.
- Simple payback
- Installed cost divided by annual savings, expressed in years. A screening metric that ignores time value of money and measure life.
- IPMVP Option C
- Whole-facility metering approach to savings verification. Compares utility bills before and after a retrofit, normalized for weather and other variables.
- Energy use intensity
- Annual site energy divided by floor area, expressed in kBtu/ft2 or kWh/m2. Used to benchmark buildings and track performance over time.
- Affinity laws
- For centrifugal fans and pumps: flow varies with speed, head with speed squared, and power with speed cubed. Basis for VFD energy savings.
- NEMA Premium motor
- An efficiency class for general-purpose induction motors. Replacing standard-efficiency motors with premium units reduces losses, especially at part load.
- Motor slip method
- Estimates motor load from measured speed: load fraction = (synchronous speed - measured speed) / (synchronous speed - rated speed) times rated horsepower.
- Lumen method
- Average maintained illuminance equals lamps times lumens per lamp times coefficient of utilization times light loss factor, divided by room area.
- LED efficacy
- Delivered lumens per watt. LED systems typically reach 100-180 lm/W versus 60-100 for fluorescent and 10-17 for incandescent lamps.
- Color rendering index
- A 0-100 scale describing how faithfully a source renders colors versus a reference. TM-30 Rf and Rg provide a more complete LED specification.
- Economizer
- A control strategy using cool outdoor air or a water-side heat exchanger to provide free cooling when conditions are favorable, reducing mechanical refrigeration.
- Sensible heat equation
- Qs (Btu/h) = 1.08 x CFM x temperature difference in Fahrenheit. Latent heat uses 0.68 x CFM x humidity ratio difference in grains.
- U-factor and R-value
- U-factor is assembly conductance in Btu/h-ft2-F; R-value is thermal resistance, the reciprocal of U. Lower U and higher R mean better envelope performance.
- BACnet
- A building automation communication protocol for sensors, controllers, and workstations. Supports interoperability across vendors; should be segmented from public networks.
- Fault detection and diagnostics
- Automated analytics that identify operational faults such as simultaneous heating and cooling, stuck dampers, sensor drift, and schedule overruns from trend data.
- Model predictive control
- A control method that optimizes setpoints over a future horizon using a building model, weather and occupancy forecasts, and equipment constraints.
- NFPA 855
- The standard for stationary energy storage system installation, covering separation distances, fire suppression, ventilation, and hazard mitigation requirements.
- Battery C-rate
- Charge or discharge power divided by capacity. A 1C rate discharges a full battery in one hour; a 0.5C rate takes two hours.
- Blowdown rate
- Percentage of feedwater drained to control boiler dissolved solids: feedwater TDS divided by (maximum boiler water TDS minus feedwater TDS) times 100.
- Steam trap survey
- Inspection using ultrasonic and infrared tools to find traps failed open (steam loss) or failed closed (water hammer, carryover). A core steam-system measure.
- PV capacity factor
- Actual annual generation divided by nameplate capacity times 8760 hours. Typical fixed-tilt commercial PV reaches roughly 13-18% depending on location.
- CHP overall efficiency
- Useful electric output plus useful thermal output divided by fuel input. Topping and bottoming cycles capture waste heat that would otherwise be rejected.
- Specific energy consumption
- Industrial energy use per unit of product, such as kWh per ton. Normalizing for production volume and product mix enables benchmarking across plants.
- Compressed air leak cost
- Leaks often waste 20-30% of compressor output. Estimate leak rate from compressor unloaded runtime; ultrasonic surveys locate and prioritize repairs.