- Fire tetrahedron
- Four components needed for flaming combustion: fuel, oxidizer, heat, and an uninhibited chemical chain reaction; removing any one extinguishes the fire.
- Flash point
- Lowest temperature at which a liquid releases enough vapor to form an ignitable mixture near its surface, but not necessarily sustain continuous burning.
- Lower flammable limit
- Minimum fuel concentration in air (by volume) that supports combustion; below this limit the mixture is too lean to ignite and propagate flame.
- Flashover
- Transition to total surface involvement in a compartment, typically when upper-layer gas temperature reaches about 600 C and floor heat flux near 20 kW/m2.
- Type V construction
- Building type with structural elements of combustible wood, including exterior walls; common in residential wood-frame construction and prone to rapid fire spread.
- Wet-pipe sprinkler system
- Automatic system with water under pressure in the piping at all times; a heat-activated sprinkler fuse opens and water discharges immediately, the most common system type.
- Fire resistance rating
- Duration in hours a building assembly resists fire exposure under standardized test conditions (ASTM E119 or UL 263), measured by temperature rise, integrity, and load capacity.
- Area of origin
- The general region where a fire began, identified by converging fire patterns, witness observations, and damage analysis; it is broader than and contains the point of origin.
- Negative corpus
- Unsupported conclusion that a fire was incendiary because all accidental causes were eliminated without evidence; NFPA 921 does not permit using elimination alone to determine incendiary cause.
- V-pattern
- Fire damage pattern that widens upward from a lower origin, produced by buoyant flame and hot gas spreading along vertical surfaces from a localized fire.
- Fire cause classification
- Four categories used in fire investigation: accidental, natural, incendiary, and undetermined; each cause must be supported by evidence and documented reasoning under NFPA 921.
- Chain of custody
- Chronological record documenting who collected, handled, transferred, and stored evidence, ensuring integrity and admissibility; gaps can undermine evidentiary value in legal proceedings.
- Control sample
- Background material collected from an unaffected area near evidence, such as subfloor or soil, used to distinguish native substances from ignitable liquid residues in laboratory analysis.
- Grid search pattern
- Systematic scene search in which the area is divided into squares inspected sequentially, ensuring complete coverage and consistent documentation of evidence locations.
- Deflagration
- Explosive combustion propagating at subsonic speed through a fuel-air mixture, producing pressure rise by expanding hot gases; most natural gas and dust explosions are deflagrations.
- BLEVE
- Boiling liquid expanding vapor explosion: failure of a tank containing pressurized liquid above its boiling point, causing rapid vaporization, fireball, and blast effects.
- Dust explosion pentagon
- Five conditions required for dust explosion: combustible dust, oxygen, ignition source, dispersion of dust into a cloud, and confinement of that cloud.
- Arc mapping
- Technique plotting electrical arcing sites on a circuit to infer fault location; useful for origin only when wiring was energized and damaged by fire and arcing is fire-caused.
- Glowing connection
- High-resistance electrical joint that heats without arcing and chars nearby material; often caused by loose connections and can be a competent ignition source.
- Battery thermal runaway
- Self-accelerating exothermic reaction in lithium-ion cells that can produce fire, toxic gas, and re-ignition; common in electric vehicle and device fires and requires copious water.
- Cognitive interview
- Structured witness interview technique using open-ended prompts, context reinstatement, and varied retrieval to improve memory recall without suggestive questioning.
- Leading question
- A question that suggests the desired answer, such as asking whether the door was open; it can contaminate witness memory and is disfavored in fire investigation interviews.
- Interview versus interrogation
- An interview is non-accusatory fact gathering, while an interrogation is accusatory and designed to elicit admissions; Miranda warnings apply to custodial interrogation.
- NFPA 921
- Guide for Fire and Explosion Investigations that describes the scientific method, fire pattern analysis, and origin and cause determination; it is a guide, not an enforceable standard.
- NFPA 1033
- Standard for Professional Qualifications for Fire Investigator, specifying requisite knowledge, skills, and continuing education, including 16 topics and keeping current with literature.
- Scientific method in NFPA 921
- Recognize need, define problem, collect data, develop hypothesis, test hypothesis by experimentation or analysis, and select the final hypothesis supported by data.
- Falsifiability
- Principle that a scientific hypothesis must be stated so it can be tested and potentially disproved; untestable explanations are not valid origin-and-cause conclusions.
- Daubert standard
- Federal admissibility test for expert testimony considering testability, peer review, known error rate, and general acceptance; the trial judge acts as gatekeeper for scientific evidence.
- Frye standard
- Older admissibility test requiring that a scientific technique be generally accepted by the relevant scientific community; still used in some state courts.
- Spoliation
- Loss, alteration, or destruction of evidence that may be relevant to litigation; can lead to sanctions, adverse inferences, or claims of negligence against investigators.
- Two-in/two-out rule
- OSHA and USFA requirement that interior structural firefighting occur in teams of at least two entering with two outside standby, wearing SCBA and full PPE.
- ISO/IEC 17025
- International standard specifying competence requirements for testing and calibration laboratories, used to accredit fire debris and forensic analysis labs and strengthen evidentiary reliability.