Bend allowance
The developed length assigned to a bend under a specified geometry and neutral-axis model, not automatically the outer arc length.
Development
The construction of a flat pattern corresponding to a formed part, accounting for actual geometry and required bend or seam allowances.
Standing seam
A raised sheet-metal joint arrangement whose actual geometry, movement and water performance depend on the specified roofing or cladding system.
Neutral axis
The modeled position in a bend with no longitudinal extension or compression, used under stated assumptions to estimate developed length.
Galvanic compatibility
Assessment of dissimilar material contact and relevant electrolyte exposure rather than assuming every metal combination performs alike.
Thermal movement allowance
A designed means to accommodate the component’s relevant temperature-related dimensional change while preserving support, weathering and attachment functions.
Waterproofing continuity
The coordinated connection of relevant layers and interfaces intended to manage water under the actual roof design and exposure.
Emergency overflow
A designed alternative water discharge route whose capacity and safe destination require actual project verification rather than a guessed dimension.
Inverted roof
A roof arrangement placing relevant insulation above the waterproofing layer, with system-specific loading, drainage and moisture considerations.
Wind uplift
An action tending to lift roof or facade components, requiring an actual load path and designed attachment or ballast.
Membrane compatibility
The suitability of adjacent membranes, adhesives, seams and accessories as a specified system rather than merely similar product labels.
Maintenance access
The planned safe means to inspect, clean, repair and replace relevant components while preserving required building functions.
Ventilated rainscreen
An enclosure arrangement separating external cladding from an inner protected assembly through a designed drained and ventilated cavity.
BIPV
Photovoltaic components integrated with a building-enclosure function, requiring both electrical and relevant structural/weather performance to be coordinated.
Fixed point
A designed restraint location controlling a panel’s reference position, coordinated with other supports and its specified movement accommodation.
Sliding point
A designed support allowing specified movement while transferring relevant forces under the actual panel and fixing system.
Thermal break
A lower-conductivity component reducing a particular heat-flow bridge without automatically eliminating all thermal or moisture risks.
Temperature coefficient
A stated rate of change of a PV quantity with cell temperature under a specified model, not an annual yield guarantee.
Controlled revision
The approved version of technical information for the actual task, preventing different workers from following incompatible dimensions, details or instructions.
Datum
A stated reference used to relate dimensions and locations consistently, rather than an arbitrary convenient edge selected independently for each part.
Written dimension
The specified physical size or relationship stated on a drawing, distinct from measuring a potentially rescaled printed image with a ruler.
System boundary
The chosen extent of a model or task that determines which inputs, outputs, forces and responsibilities are included in the reasoning.
Measurement uncertainty
A characterization of the possible dispersion associated with a measurement result, distinct from the instrument’s smallest display increment.
Acceptance criterion
A defined requirement used to judge appropriate evidence, which must not be replaced by an attractive appearance or an undocumented expectation.
SMAW
Shielded metal arc welding using a flux-coated consumable electrode, with actual classification and parameters governed by the relevant approved procedure.
GMAW
Gas metal arc welding using a continuously fed consumable electrode and appropriate external shielding under specified process conditions.
GTAW
Gas tungsten arc welding using a nonconsumable tungsten electrode, with separate filler added where the actual procedure requires it.
Heat-affected zone
Base material altered by welding heat without being melted as weld metal, with properties influenced by material and thermal history.
Heat input
A process-energy measure calculated using a stated formula and units, whose interpretation depends on whether efficiency and travel conditions are included.
Interpass temperature
The relevant temperature condition between weld passes, controlled according to the actual material and approved procedure rather than a universal number.