Cisco DCIT 300-615 flashcards
Cisco DCIT 300-615 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- vPC type-1 vs type-2
- Type-1 parameters (MTU, STP mode, VXLAN source, etc.) must match on both vPC peers or vPC stays down. Type-2 parameters (e.g., VLAN lists, allowed VLANs) only generate a warning and vPC stays up.
- vPC peer-keepalive purpose
- Heartbeat over a separate L3 path (management or dedicated link) that lets peers detect each other's liveness even when the peer link fails, preventing split-brain and dual-active forwarding.
- vPC peer link role
- Carries control traffic (CFS, STP BPDUs, ARP sync) and orphan/data traffic when the peer is reachable; if it fails while keepalive is up, the secondary suspends its vPC member ports.
- vPC consistency-parameters command
- 'show vpc consistency-parameters global' and 'interface <if>' list per-parameter local values on both peers and mark type-1 (mandatory) versus type-2 (advisory) mismatches.
- Suspended port-channel member
- Member shows 's' or 'I' in 'show port-channel summary'; caused by speed/duplex/MTU mismatch, LACP mode mismatch, VLAN mismatch, or vPC type-1 mismatch. Check 'show port-channel compatibility-parameters'.
- CRC and input errors
- Rising FCS/CRC counters on an interface indicate Layer 1 problems: bad cable, dirty connector, failing SFP, or duplex mismatch. Confirm with 'show interface counters errors' and transceiver DOM levels.
- NVE peer state verification
- 'show nve peers' should show peer state Up for every VTEP; 'show nve vni' shows VNI state and mode (CP/DP). Down peers usually indicate underlay reachability or BGP EVPN session failure.
- EVPN route types
- Type-2 advertises MAC/IP; Type-3 advertises inclusive multicast (BUM); Type-5 advertises IP prefix; Type-1 Ethernet auto-discovery for multihoming; Type-4 Ethernet segment. Verify with 'show bgp l2vpn evpn route-type'.
- VXLAN underlay requirements
- Underlay must provide IP reachability between VTEP loopbacks, MTU sized for 50-byte VXLAN overhead, and PIM/ingress-replication for BUM traffic. Verify with 'show ip route' and 'show nve interface nve1'.
- FabricPath ISIS adjacency
- 'show fabricpath isis adjacency' should show all spine/leaf neighbors Up. Down adjacencies indicate link, MTU, or ISIS authentication mismatch; 'show fabricpath route' confirms switch-id reachability.
- STP root verification
- 'show spanning-tree vlan <id>' shows root bridge ID, local bridge ID, and port roles. If the expected root is not elected, check bridge priority, extended system ID, and vPC/STP domain consistency.
- Control-plane CPU diagnosis
- 'show processes cpu sort | head' and 'show processes cpu history' identify the top consumers. Sustained high CPU from a single process (e.g., BGP,ARP) suggests a loop, flapping neighbor, or misbehaving feature.
- Logging severity levels
- Syslog severities 0-7: 0 emergencies, 1 alerts, 2 critical, 3 errors, 4 warnings, 5 notifications, 6 informational, 7 debugging. 'logging level <feature> <n>' sends messages at or below that severity.
- show tech-support collection
- Bundle of show outputs (interfaces, routes, hardware, logs) used for TAC cases. On NX-OS it writes to bootflash by default; collect before rebooting or clearing counters.
- Port-channel LACP neighbor check
- 'show lacp neighbor' shows each member's partner system ID, port state, and flags. Mismatched partner or 'Suspended' state indicates cabling to the wrong peer or LACP mode mismatch.
- Configuration rollback
- 'configure replace <file>' or 'rollback running-config checkpoint <name>' restores a prior state. Verify with 'show archive config differences' to preview deltas before committing.
- Transceiver DOM diagnostics
- 'show interface <if> transceiver details' shows Rx/Tx power in dBm. Rx power below spec or 'N/A' indicates a failed SFP, dirty fiber, or wrong optics type; check against vendor thresholds.
- show module status
- Lists supervisor and line card slots with status (ok, powered-up, failure). A 'failure' or 'powered-down' state indicates hardware or slot power issue; check 'show environment' for PSU/thermal faults.
- vPC orphan port
- A port in a vPC VLAN that is not a vPC member and is up on only one peer. Traffic reaches it via the peer link; if the peer link fails, orphan ports on the secondary are suspended.
- BGP EVPN neighbor state
- 'show bgp l2vpn evpn summary' shows peer state and prefix counts. Idle/Active indicates TCP/port 179 or reachability issue; Established but no routes indicates route-target or address-family mismatch.
- Interface MTU mismatch
- MTU mismatch on a trunk or vPC member causes large frames to drop silently. Verify with 'show interface' MTU field and 'show run interface'; VXLAN underlay needs MTU >= 1550 typically.
- ARP and MAC table verification
- 'show ip arp vrf <name>' and 'show mac address-table' confirm learning. Missing entries point to VLAN/VRF misconfiguration, STP blocking, or vPC/EVPN learning failure.
- Interface flap detection
- 'show interface <if>' shows 'last link flapped' and 'reset counters interface' clears stats. Frequent flaps indicate cabling, SFP, or negotiation issues; correlate with 'show logging logfile'.
- show environment output
- Displays fan tray, power supply, and temperature sensor status. Any 'failure' or 'not ok' entry indicates a hardware or cooling issue that can cause line card resets or shutdowns.
- VRF route table check
- 'show ip route vrf <name>' and 'show ip route vrf <name> summary' confirm per-tenant routing. Missing routes indicate VRF-to-global leak misconfig, missing 'ip route' statements, or BGP/OSPF not redistributing.
- NVE VNI mode CP vs DP
- 'show nve vni' mode CP (control-plane, via BGP EVPN) or DP (data-plane, static/flood-and-learn). Wrong mode prevents EVPN MAC learning; verify 'vni <id> mcast-group' or 'l2' config under nve.
- LLDP topology mapping
- 'show lldp neighbors' and 'show cdp neighbors detail' reveal adjacent device, port, and management IP. Useful to confirm cabling matches the intended topology before changing vPC or fabric config.
- Interface counters errors
- 'show interface counters errors' lists FCS, runts, giants, input/output errors per port. Non-zero sustained values indicate physical layer faults or duplex/MTU mismatch; clear with 'clear counters interface'.
- vPC role and priority
- 'show vpc role' shows primary/secondary and operational priority. Lower priority number wins; if both peers show primary, peer link/keepalive is broken and split-brain may be active.
- Process memory leak check
- 'show processes memory sort | head' identifies top consumers; compare over time or after reload. Steady growth in a single process suggests a leak; capture 'show tech-support' before restart.
- show running-config diff
- Compares running config against a prior snapshot or checkpoint, showing added and removed lines. Use to validate that a change applied as intended and no unintended deltas exist.
- VLAN allowed list mismatch
- On a trunk, 'switchport trunk allowed vlan' must include the VLANs carried. Missing VLANs cause silent drops; verify on both ends and on vPC peers with 'show interfaces trunk'.