Cisco 300-625 DCSAN flashcards
Cisco 300-625 DCSAN · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- VSAN 1 default
- VSAN 1 is the default VSAN on every MDS switch and cannot be deleted. Ports are assigned to it by default until moved to another VSAN using the vsan database command.
- setup script
- The initial configuration utility on an MDS switch. It prompts for the admin password, mgmt0 IPv4 or IPv6 address, and default gateway, and can optionally configure NTP and AAA.
- install all system
- The NX-OS command that upgrades both the kickstart and system images together. Adding the non-disruptive keyword upgrades one supervisor at a time on dual-supervisor systems.
- show interface brief
- Displays every port with its administrative state, mode, and operational state, including F, FL, E, TE, NP, Fx, and down, plus the assigned VSAN.
- RBAC role command
- The role name command creates a custom role, and rule statements grant read or read-write access to feature groups. The username command then assigns the role to a user.
- write erase
- Removes the startup configuration from the switch. After a reload, the switch returns to factory defaults and the setup script runs again.
- SAN port-channel
- A bundle of ISLs created with interface san-port-channel N and channel-group N. Member ports become TE ports, and show port-channel summary verifies the bundle state.
- show license usage
- Lists installed licenses and shows which features are currently consuming them. Features such as NPV, NPIV, FCoE, and IVR fail to enable without an installed license.
- Principal switch election
- The switch with the lowest switch WWN becomes the principal switch. It assigns domain IDs to all other switches in the fabric, and show fcdomain displays the result.
- FLOGI
- The fabric login process in which an N-port requests an FC-ID from the principal switch. The port then registers with the name server, visible in show flogi database.
- zoneset activate
- The command that activates a zoneset in a VSAN. Only one zoneset can be active per VSAN, and zoneset distribute full pushes it to peer switches.
- default-zone deny
- When no zoneset is active, this setting blocks all traffic between ports. The default-zone permit setting instead allows all traffic. Enhanced zoning stores the choice fabric-wide.
- Segmented ISL
- An ISL that fails the domain or zone merge appears isolated in show interface brief. Resolve by matching domain IDs or zoning, then restart fcdomain or activate the zoneset.
- FSPF
- The Fabric Shortest Path First routing protocol used inside a VSAN. It builds a link-state database, and show fspf vsan N displays routes and neighbor state.
- device-alias commit
- The command that applies entries in the device-alias database. Aliases can then be used in zones instead of pwwn values, and device-alias distribute shares them fabric-wide.
- IVR
- Inter-VSAN Routing lets devices in different VSANs communicate. It requires an IVR license, an ivr vsan-topology database, and ivr zoneset activate on the border switches.
- Domain ID range
- Valid Fibre Channel domain IDs are 1 through 239. Values 0 and 255 are reserved, and a static domain is set with fcdomain domain N static followed by a disruptive restart.
- NPV enable
- This command turns the switch into a non-principal switch. Upstream ports become NP ports connected to core F ports, and downstream ports remain F ports.
- NPIV
- N_Port ID Virtualization lets one F-port carry logins for many N-ports, each receiving a fabric-provided FC-ID. The core switch must support NPIV for NPV to work.
- show npv flogi-table
- Displays the proxied FLOGI entries that an NPV switch forwarded to the core. It lists server WWPNs, assigned FC-IDs, and the upstream interface used.
- NPV traffic-map
- A configuration that pins a downstream server to a specific upstream NP port. It controls which core link carries that server's traffic when multiple uplinks exist.
- vFC interface
- A virtual Fibre Channel interface created with interface vfc N and bound to an Ethernet port. It carries FCoE traffic for a VSAN and appears as an F port.
- FCoE license
- A feature license required before feature fcoe can be enabled on an MDS switch. Without it, FCoE configuration is rejected and show license usage shows no consumption.
- FIP
- The FCoE Initialization Protocol. It performs VLAN discovery, FLOGI, and fabric login before FCoE frames flow, and its endpoints are the ENODE and the FCF.
- FCoE CoS value
- FCoE traffic uses CoS 3 by default. Lossless Ethernet requires priority flow control and a no-drop class so that FCoE frames are not dropped during congestion.
- show npv status
- Displays whether NPV is enabled, the number of server and client interfaces, and the state of each external interface. It confirms the NPV configuration is active.
- Port security
- A feature that restricts which device WWPNs may log in to a port. Entries are added to a database, activated per VSAN, and violations trigger a shutdown action.
- DHCHAP
- The FC-SP authentication protocol that verifies peers using a shared secret or hash. It is enabled with fcsp dhchap and verified with show fcsp.
- Port tracking
- A feature that links tracked ports so that when one fails, its associated ports are also brought down. It prevents traffic black-holing after an uplink failure.
- Call Home
- An alerting feature that sends notifications to configured destinations such as email or HTTP. Alert groups select which events trigger a message, and call-home send tests delivery.
- Smart zoning
- A zoning mode that compresses a zone so each initiator-target pair becomes its own zone. It reduces TCAM usage and is enabled per VSAN with zone smart-zoning enable.
- Slow-drain detection
- A mechanism using port-monitor policies and timeouts to identify devices that hold frames too long. Isolating those devices prevents congestion from spreading across the fabric.