CMEG study materials
CMEG study resources

CMEG flashcards

CMEG · Build recall with a focused review session.

24 cards. Read the term and the definition here. The deck at the top of this page is optional.

Magnetometer
A magnetic sensor measuring field under its actual geometry and operating requirements rather than directly identifying individual neurons.
Gradiometer
A sensor arrangement responding to spatial field differences that can reduce some distant interference but not every artifact.
Empty-room recording
A measurement characterizing aspects of system and environmental noise without capturing every patient-related source of contamination.
Phantom assessment
A test under known conditions used to evaluate specified system performance without guaranteeing every clinical localization.
Device screening
Review of relevant implants, accessories and system-specific risks before the proposed recording or stimulation activity.
Impedance balance
The relationship between input contact impedances that can affect noise rejection and should be considered with actual equipment.
Clinical event annotation
Accurate recording of observed patient behavior and timing when safe, without independently assigning an unsupported diagnosis.
Cryogenic hazard
A cold, pressure or atmospheric risk associated with the actual cryogenic system, requiring trained procedures and response.
Differential amplification
Measurement of a difference between inputs with designed rejection of common signals, subject to actual equipment and contact conditions.
Aliasing
Misrepresentation of higher-frequency content at lower apparent frequencies when sampling and filtering conditions are unsuitable.
Latency jitter
Variation in response timing across trials that can blur a time-locked average even when individual responses exist.
Coherent artifact
Interference that repeats systematically with the event or stimulus and may therefore persist during averaging.
Head localization
Determination of the head’s relationship to the sensor coordinates using the appropriate system-specific procedure and quality checks.
Event marker
Stored timing information linked to an event that must be related correctly to actual stimulus delivery or behavior.
Concurrent EEG-MEG
Recording of complementary electrical and magnetic measurements whose different sensitivities can affect the visibility of an event.
Task validity
Evidence that the person understood and performed the intended activity sufficiently for the proposed mapping interpretation.
Forward solution
A model prediction of sensor measurements from assumed source currents, geometry and relevant head-model conditions.
Inverse estimate
An inferred source explanation for measured fields that depends on constraints and is not uniquely determined by the measurements alone.
Coregistration
Alignment of functional measurement coordinates with structural anatomy, requiring correct identity, labels, landmarks and quality review.
Goodness of fit
A measure of model-data agreement that does not independently establish anatomical accuracy, epileptogenicity or a clinical outcome.
Contemporaneous record
A record made with reliable timing near the event rather than reconstructed later from uncertain memory.
Closed-loop alert
A communication in which the finding is stated and receipt or understanding is confirmed through the agreed pathway.
Processing provenance
A traceable history of settings, exclusions, software and transformations needed to review or reproduce an analysis.
Raw data preservation
Retention of the original measurement and relevant metadata so later processing does not replace the only source evidence.