Radiology Technology Qualification (China) - independent subject foundations study materials
Radiology Technology Qualification (China) - independent subject foundations study resources

Radiology Technology Qualification (China) - independent subject foundations key terms

Radiology Technology Qualification (China) - independent subject foundations · Get comfortable with the vocabulary.

Attenuation

Reduction of a beam through interaction with matter, interpreted using the energy spectrum, material and geometry rather than treated as an image-display adjustment.

Half-value layer

The thickness that reduces beam intensity by one half under the specified measurement conditions, related to beam quality and the relevant attenuation model.

Absorbed dose

Energy deposited per unit mass, expressed in gray, distinct from weighted dose quantities, an exposure index or an individual probability of disease.

Effective dose

A weighted protection quantity used for specified comparisons and assessments, not an exact direct measurement of one patient’s biological injury.

Scatter

Radiation redirected through interaction, which can reduce image contrast and contribute to occupational exposure in a way that depends on the geometry.

Collimation

Restriction of the useful beam field to appropriate anatomy, requiring a balance between task coverage, exposure and avoiding unnecessary irradiated areas.

Grid cutoff

Loss of useful radiation reaching the receptor because of grid misuse or geometry, which can degrade an image and require proper cause investigation.

Exposure index

A detector-related indicator of acquisition exposure under its defined convention, distinct from image brightness and exact absorbed dose to the patient.

Quantum noise

Statistical variation related to detected photon numbers, which must be distinguished from motion, detector, grid and processing artifacts.

Modulation transfer

Description of how an imaging system transfers contrast at different spatial frequencies under defined conditions, rather than one universal clinical quality score.

Pitch

In helical CT, table travel per rotation divided by nominal total beam width, with dose effects depending on other parameters and output control.

Window level

The center of the displayed CT attenuation range in the specified window setting, which changes presentation rather than the acquired tissue attenuation.

Window width

The span of attenuation values allocated across the displayed grayscale in a CT window, interpreted together with its level and display convention.

Longitudinal relaxation

Recovery of longitudinal magnetization after excitation in MRI, described by T1 under the specified model and not interchangeable with transverse signal decay.

Apparent diffusion coefficient

An imaging-derived description of diffusion behavior that helps interpret diffusion-weighted signal within the relevant acquisition and clinical context.

Piezoelectric effect

Conversion between mechanical and electrical behavior in suitable materials, used for generation and reception of diagnostic ultrasound signals.

Aliasing

Misrepresentation arising when sampling is insufficient for the relevant signal variation, with particular acquisition-dependent forms in MRI and pulsed Doppler.

MR Conditional

A labeling category identifying defined conditions for use in the MR environment, requiring verification rather than an assumption of unrestricted safety.

Justification

Assessment of whether an imaging procedure is appropriate for its intended clinical purpose and person, considering expected benefits, risks and relevant alternatives.

Optimization

Adjustment of an appropriate examination to obtain necessary information while managing exposure and other risks, rather than simply minimizing all signals or all tests.