CRI flashcards
CRI · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Category 1 water
- Water from a sanitary source that does not pose a substantial risk from ingestion or inhalation, such as a supply line break or rainwater. It can degrade to Category 2 if left standing.
- Category 2 water
- Gray water that contains significant contamination, such as washing machine discharge, dishwasher effluent, or toilet overflow without solids. It requires PPE and more aggressive cleaning than Category 1.
- Category 3 water
- Grossly contaminated water such as sewage, floodwater, or toilet trap water. It contains pathogens and requires full PPE, removal of porous materials, and disinfection of salvageable surfaces.
- Class 1 water damage
- The lowest evaporation load: minimal water absorption, with only a small portion of the room's materials wet. Drying usually takes the least time and equipment.
- Class 4 water damage
- The highest evaporation load, involving deep pockets of water in low-permeability materials such as hardwood, concrete, or subfloor. Requires specialty drying equipment and longer drying times.
- Air mover placement
- A starting rule is one air mover per 10-14 linear feet of affected wall or per 50-70 square feet of wet floor. Arrange them to create a circular airflow pattern.
- Extraction before drying
- Removing standing water and extracting wet carpet is the first and most important step. Equipment works far more efficiently when bulk water has already been removed.
- Antimicrobial regulation
- Antimicrobials are pesticides regulated under FIFRA. Only EPA-registered products labeled for the specific use may be applied, and they never replace cleaning.
- Pin-type moisture meter
- A meter that measures electrical conductivity between two pins driven into the material. It reads moisture content well on wood and drywall but leaves small holes.
- Pinless moisture meter
- A capacitance-based meter that scans a surface without pins, reading to a depth of about one inch. It is useful for scanning large areas before pin confirmation.
- Thermal imaging limits
- Thermal cameras show temperature differences from evaporative cooling but cannot confirm moisture. Every thermal anomaly must be verified with a moisture meter.
- Moisture map
- A documented diagram of the affected area showing moisture readings, material types, and equipment placement. It supports drying decisions and insurance claims.
- Outdoor control sample
- An air sample collected outside at the same time as indoor samples. Indoor mold spore results are compared against it to judge whether indoor levels are elevated.
- Air sampling purpose
- Air sampling is a screening tool that shows a snapshot of airborne spores. It is not a clearance test and does not by itself prove a health risk.
- Borescope inspection
- A camera on a flexible probe used to inspect wall cavities, ductwork, and other enclosed spaces where visible access is limited. Useful for finding hidden mold.
- Scope of work report
- A written document defining the affected area, water category and class, affected materials, and the recommended drying or remediation approach. The client signs it before work begins.
- Drying goal
- Materials should return to their pre-loss moisture content, typically 10-12% for wood framing and 0.5-1% for drywall. Progress is judged by daily readings, not a fixed schedule.
- Drying chamber
- A sealed containment around the affected area that controls temperature, humidity, and airflow. Negative pressure is used when contamination is present.
- Hardwood floor drying
- Drying mats and controlled airflow remove moisture from hardwood floors. Sanding or refinishing must wait until the floor reaches its target moisture content.
- Category 3 material removal
- Porous materials exposed to grossly contaminated water, such as carpet, pad, and drywall below the flood line, are removed rather than dried in place.
- Reconstruction sequencing
- New drywall and flooring are installed only after the structure is confirmed dry. Installing over wet framing traps moisture and causes future mold growth.
- Soot removal urgency
- Soot is acidic and corrosive to metal and finishes. It should be removed promptly with dry sponges and appropriate cleaners, followed by HEPA vacuuming and air scrubbing.
- Contents pack-out
- Removing furnishings and belongings for cleaning and storage. Each item is inventoried, photographed, and cleaned by a method suited to its material.
- Post-remediation verification
- Documented confirmation that drying or remediation met its goal, using moisture readings, visual inspection, and where required independent clearance sampling.
- Mold moisture requirement
- Mold growth requires sufficient moisture, generally water activity above 0.8 or relative humidity above about 60%. Correcting the moisture source is essential to remediation.
- Level I remediation
- A small mold job affecting less than 10 square feet. It can often be handled with limited containment and basic PPE by trained personnel.
- Level III remediation
- A large mold job affecting more than 100 square feet. It typically requires full containment, negative pressure, and a licensed or certified remediation professional.
- Negative pressure containment
- A sealed poly barrier with HEPA-filtered air scrubbers that keep the contained space at lower pressure, so air flows inward and spores do not escape.
- HEPA filtration rating
- A filter rated to capture 99.97% of particles at 0.3 microns. HEPA vacuums and air scrubbers are standard equipment for mold remediation.
- Mold PPE
- Minimum protection includes an N95 or P100 respirator, goggles, gloves, and disposable coveralls. Larger or contaminated jobs may require a full-face respirator or PAPR.
- Porous material disposal
- Moldy drywall, insulation, and carpet are generally removed and bagged rather than cleaned. Semi-porous and non-porous materials can be cleaned with detergent.
- Mold clearance criteria
- Clearance requires no visible mold or dust, moisture readings at the dry standard, and where specified, air sampling comparable to outdoor control levels, verified independently.