CT Water Operator study materials
CT Water Operator study resources

CT Water Operator flashcards

CT Water Operator · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

CT
Disinfectant contact time value, calculated as residual concentration (mg/L) multiplied by contact time (minutes), used to determine pathogen inactivation credit.
Log removal
A logarithmic expression of pathogen reduction; 1-log = 90%, 2-log = 99%, 3-log = 99.9%, 4-log = 99.99% removal or inactivation.
Surface loading rate
Flow rate divided by clarifier surface area, expressed in gpm/ft²; typical values for sedimentation are 0.5–1.0 gpm/ft².
Filtration rate
Flow rate divided by filter surface area, expressed in gpm/ft²; rapid sand filters typically operate at 2–5 gpm/ft².
Backwash
Reverse flow through a filter to clean media; must expand bed 15–25%; rate = flow (gpm) / filter area (ft²).
Detention time
Theoretical time water is held in a tank or basin; volume divided by flow rate, expressed in hours or days.
Chlorine demand
The amount of chlorine consumed by impurities in water; calculated as dose minus residual after a specified contact time.
Jar test
Laboratory procedure that simulates coagulation, flocculation, and sedimentation to determine optimal coagulant dose and pH.
LSI
Langelier Saturation Index; indicates water's tendency to scale (positive) or corrode (negative); target near zero.
Minimum distribution pressure
Regulatory minimum of 20 psi throughout the distribution system under normal and fire-flow conditions to prevent contamination.
Hazen-Williams formula
Empirical equation for head loss in pipes: h_f = 10.44 L Q^1.85 / (C^1.85 d^4.87) in SI units, where C is roughness coefficient.
Water hammer
Pressure surge caused by sudden velocity change in a pipe; surge pressure = 0.07 × velocity change (ft/s) × wave speed (ft/s).
Fire flow
Flow rate and duration required for firefighting, typically 500–3,500 gpm for 2–4 hours, determined by local fire code.
Storage volume
Total capacity including equalization, fire flow, and emergency reserve; typically 1.5–2.0 times average day demand.
Pipe velocity
Speed of water in a pipe; typical design range 2–5 ft/s; below 1 ft/s causes sedimentation, above 10 ft/s causes excessive head loss.
Chlorine residual
Measurable chlorine remaining after demand is satisfied; minimum 0.2 mg/L must be maintained throughout distribution.
Cross-connection control
Backflow prevention using air gap (preferred) or reduced pressure zone assembly to protect potable water from contamination.
Distribution flushing
Controlled release of water at minimum 2.5 ft/s velocity to scour biofilm and sediment from mains.
Turbidity
Measure of water clarity by nephelometry in NTU; treatment technique requires ≤0.3 NTU in 95% of monthly samples for conventional filtration.
pH
Measure of hydrogen ion concentration; typical range 6.5–8.5; affects coagulation, disinfection efficiency, and corrosion.
DPD method
Colorimetric method for measuring chlorine residual; free chlorine read after 2 minutes, total after adding KI.
Total coliform
Bacterial indicator tested by presence/absence method; a positive result requires repeat sampling and investigation.
HPC
Heterotrophic plate count; pour plate method; result <500 CFU/mL indicates adequate treatment and distribution system integrity.
Fluoride
Measured by ion-selective electrode or colorimetric method; optimal 0.7–1.2 mg/L; MCL 4.0 mg/L.
Nitrate
Measured by ion chromatography or cadmium reduction; MCL 10 mg/L as nitrogen; can cause methemoglobinemia in infants.
Lead and copper
Action levels: Pb 0.015 mg/L, Cu 1.3 mg/L at 90th percentile; corrosion control treatment required if exceeded.
TTHM and HAA5
Disinfection byproducts; MCLs: TTHM 0.080 mg/L, HAA5 0.060 mg/L, based on locational running annual average.
Total coliform rule
Requires no more than 5% positive samples per month for systems >40 samples; any positive triggers repeat within 24 hours.
Surface Water Treatment Rule
Requires 99.9% (3-log) Giardia and 99.99% (4-log) virus removal/inactivation for surface water systems.
Stage 2 DBPR
Disinfectants/Disinfection Byproducts Rule; sets LRAA limits for TTHM and HAA5 to reduce exposure.
Arsenic MCL
Maximum contaminant level of 0.010 mg/L (10 ppb) for arsenic in drinking water.
Consumer Confidence Report
Annual report due July 1 that informs customers about source water, detected contaminants, and health effects.