- ALARA
- Principle requiring that occupational and patient radiation exposure be kept as low as reasonably achievable, using time, distance, and shielding without sacrificing diagnostic quality.
- Inverse square law
- Radiation intensity is inversely proportional to the square of the distance from the source; doubling distance reduces intensity to one quarter of its original value.
- Maximum permissible dose
- Annual occupational limit of 50 mSv (5 rem) for radiation workers; the general public limit is 1 mSv (0.1 rem) per year.
- Personnel dosimeter badge
- Film, TLD, or OSL badge worn at collar level outside the lead apron to record cumulative occupational radiation dose, reported as shallow and deep dose.
- Thyroid collar
- Lead shield worn around the neck during intraoral radiography and pediatric panoramic exposures to reduce radiation dose to the thyroid gland.
- Rectangular collimation
- Restricting the x-ray beam to a rectangular shape matching the image receptor, reducing the volume of patient tissue exposed compared with round collimation.
- Digital sensor exposure
- Digital receptors require roughly one-third to one-half the exposure of film; increasing exposure to compensate degrades image quality and raises patient dose.
- Film badge over-read
- A dosimeter reading above expected levels must be reported to the radiation safety officer for investigation; it is not a reason to alter patient treatment.
- Chain of infection
- Six links: infectious agent, reservoir, portal of exit, transmission mode, portal of entry, susceptible host; breaking any link prevents transmission.
- Standard precautions
- Infection control measures applied to all patients regardless of diagnosis, including hand hygiene, gloves, mask, eye protection, and safe sharps handling.
- Critical item
- An instrument or device that penetrates tissue or contacts the bloodstream, such as scalers and forceps, and therefore must be sterilized before reuse.
- Semicritical item
- An item that contacts mucous membranes but does not penetrate tissue, such as mirrors and impression trays; it requires sterilization or high-level disinfection.
- Spore test
- Biological indicator using Geobacillus stearothermophilus for steam sterilizers and Bacillus atrophaeus for dry heat or ethylene oxide; a positive result removes the unit from service.
- Surface barrier
- A disposable plastic cover placed over difficult-to-clean surfaces such as light handles; it is replaced between patients and does not replace end-of-day disinfection.
- Sharps container limit
- Rigid, puncture-resistant, labeled container is filled no more than three-quarters full and replaced to prevent accidental needle sticks during disposal.
- Transfer zone
- Area over the patient's chest where instruments are exchanged between dentist and assistant using a consistent pen-grip hand position and announced sequence.
- High-volume evacuation
- Suction tip held within about one to two centimeters of the operative site to remove debris, coolant, and aerosols; the saliva ejector is not a substitute.
- Lidocaine 2% cartridge
- A 1.8 mL cartridge contains 36 mg lidocaine; with 1:100,000 epinephrine it contains 0.018 mg epinephrine and is the most common dental anesthetic.
- Maximum lidocaine dose
- Recommended maximum of 4.4 mg per kilogram, with an absolute adult limit near 300 mg; divide total milligrams by 36 to calculate cartridges.
- Rubber dam inversion
- After clamping the anchor tooth, the dam margin is tucked under the gingival sulcus with floss to create a seal that isolates the field and protects the airway.
- Tofflemire matrix
- A retainer and band system used for posterior Class II restorations to establish the proximal contour and confine the restorative material during placement.
- Sectional matrix and wedge
- A contoured sectional band plus wedge used for tight proximal contacts in Class II composite restorations; the wedge also protects the adjacent tooth.
- Composite curing increments
- Composite is placed in increments of about two millimeters and light-cured between layers to ensure adequate depth of polymerization and reduce shrinkage stress.
- Universal tooth numbering
- Permanent teeth numbered 1 through 32 starting with the maxillary right third molar; primary teeth are lettered A through J maxillary and K through T mandibular.
- FDI tooth notation
- Two-digit system where the first digit is the quadrant (1–4 permanent, 5–8 primary) and the second digit is the tooth position from the midline (1–8).
- Periodontal probing depth
- Depth in millimeters from the gingival margin to the base of the sulcus; 1–3 mm is healthy, 4 mm suggests gingivitis, and 5 mm or more suggests periodontitis.
- Bleeding on probing
- A sign of active gingival inflammation; it is recorded during periodontal charting and indicates the need for further assessment and possible scaling and root planing.
- Caries demineralization
- Bacterial acids from Streptococcus mutans and Lactobacillus dissolve enamel mineral; saliva and fluoride promote remineralization as acid-resistant fluorapatite.
- Syncope management
- For fainting, place the patient supine with legs elevated, loosen tight clothing, monitor vital signs, and activate emergency services if consciousness does not return promptly.
- Adult vital signs
- Normal ranges: blood pressure below 120/80 mmHg, pulse 60–100 beats per minute, respiration 12–20 per minute, temperature 36.1–37.2 degrees Celsius.
- Exposure control plan
- Written OSHA-required program covering standard precautions, hepatitis B vaccination offer, annual training, and a sharps injury log for the dental office.