DANB CDIPC · Keep the key ideas within reach.

Quick reference

Infection Prevention and Control Program Management and Leadership

  • OSHA Bloodborne Pathogens Standard (29 CFR 1910.1030) requires a written Exposure Control Plan that is reviewed and updated at least annually.

  • Hepatitis B vaccination must be offered within 10 working days of initial assignment, at no cost to the employee, unless already vaccinated or medically contraindicated.

  • Bloodborne pathogens training is required at initial assignment and at least annually thereafter; training records are retained for 3 years.

  • Employee medical records are retained for the duration of employment plus 30 years.

  • A sharps injury log records the type and brand of device, the work area, and an explanation of the incident while protecting confidentiality.

  • Post-exposure evaluation and follow-up are provided at no cost and include confidential medical evaluation and source-individual testing where permitted.

  • CDC's Guideline for Infection Control in Dental Health-Care Settings (2003) is the standard clinical reference; employers must also meet OSHA and state rules.

  • The employer holds ultimate legal responsibility for the infection control program; a qualified coordinator may be designated to manage day-to-day operations.

  • Standard precautions apply to every patient regardless of presumed infectious status or medical history.

Quick reference

Standard Precautions

  • Standard precautions treat all blood, saliva, and body fluids as potentially infectious, applying the same safeguards to every patient.

  • Perform hand hygiene before patient contact, after glove removal, and whenever hands are visibly contaminated.

  • Select PPE based on anticipated exposure: gloves for all patient contact, plus mask, eye protection, and gown when splash or spatter is likely.

  • Use single-use needles and never recap by the two-handed method; use a scoop technique or a recapping device if recapping is unavoidable.

  • Place sharps immediately into puncture-resistant, closable, leakproof, labeled containers located at the point of use.

  • Respiratory hygiene and cough etiquette measures are implemented for patients with signs of respiratory illness.

  • Clean and disinfect contaminated clinical contact surfaces, or use impervious barriers that are replaced between patients.

  • Do not eat, drink, apply cosmetics, or handle contact lenses in areas where blood or body fluids may be present.

  • For blood spills, absorb visible material, clean, then apply an EPA-registered hospital disinfectant with a tuberculocidal claim or a fresh 1:10 bleach dilution.

Quick reference

Hand Hygiene and Personal Protective Equipment

  • Alcohol-based hand rub is preferred for hands that are not visibly soiled; use soap and water when hands are visibly soiled or contaminated with blood or body fluids.

  • Alcohol-based hand rub is applied for 20-30 seconds; soap-and-water handwashing lasts at least 20 seconds.

  • Gloves never replace hand hygiene; perform hand hygiene before donning and immediately after removing gloves.

  • Do not wash, disinfect, or reuse disposable gloves; remove gloves before touching clean surfaces, charts, or equipment.

  • Change masks between patients or when wet or soiled; surgical masks are not respiratory protection, and N95 respirators require fit testing.

  • Eye protection must include side shields; reusable eyewear is cleaned and disinfected between patients.

  • Remove PPE in a sequence that minimizes contamination: gloves first (most contaminated), then eyewear and gown, and mask last, followed by hand hygiene.

  • Keep natural nails short; artificial nails and fingernail polish are avoided because they harbor microorganisms.

  • Remove gowns and lab coats before leaving clinical areas and launder them according to facility policy.

Quick reference

Instrument Processing

  • Transport contaminated instruments in a covered container to the processing area; keep them moist with a transport gel if cleaning is delayed.

  • Cleaning must precede sterilization: use manual scrubbing, an ultrasonic cleaner, or a washer-disinfector to remove bioburden.

  • Ultrasonic cleaner solution is changed at least daily and more often when visibly soiled; instruments are then rinsed and dried.

  • Critical instruments penetrate soft tissue or bone (e.g., extraction forceps, scalpel blades, surgical burs) and must be sterile after use.

  • Semicritical instruments contact mucous membranes (e.g., mouth mirrors, amalgam condensers) and require sterilization or high-level disinfection.

  • Noncritical items contact only intact skin and require cleaning plus low- or intermediate-level disinfection.

  • Package instruments with an internal chemical indicator when the indicator cannot be seen from outside; place an external process indicator on each package.

  • Heat-sensitive semicritical items are processed with an EPA-registered high-level disinfectant/chemical sterilant according to label contact time.

  • Handpieces are cleaned, lubricated per manufacturer instructions, and sterilized between patients; waterlines are flushed before use.

Quick reference

Sterilization and Disinfection

  • Sterilization destroys all microorganisms including bacterial spores; disinfection reduces or eliminates pathogens but may not kill spores.

  • Gravity-displacement steam autoclave cycle: 121°C (250°F) at 15 psi for 15-20 minutes, or 132°C (270°F) for 4 minutes.

  • Dry-heat sterilization: 160°C (320°F) for 2 hours or 170°C (340°F) for 1 hour.

  • Biological monitoring (spore testing) is performed at least weekly; steam and chemical vapor indicators use Geobacillus stearothermophilus, and dry heat uses Bacillus atrophaeus.

  • Every package receives an external process indicator; internal chemical indicators are placed inside packages that cannot be visualized.

  • A positive spore test requires removing the sterilizer from service, repeating the test, investigating the cause, and recalling affected loads.

  • Implants and other items requiring sterility assurance are quarantined until the biological indicator from that load is negative.

  • Do not overload the sterilizer; allow a drying cycle so packages remain dry and intact after removal.

Quick reference

Environmental Asepsis

  • Clinical contact surfaces (light handles, switches, bracket trays, keyboards) are cleaned and disinfected between patients or covered with impervious barriers that are replaced.

  • Housekeeping surfaces such as floors and sinks are cleaned at least daily and whenever visibly soiled.

  • Use a clean-to-contaminated workflow; separate clean and contaminated areas and process instruments in a one-way direction.

  • Barrier protection is used for surfaces that are difficult or damaging to disinfect, such as electrical switches and computer equipment.

  • Avoid touching clean surfaces, drawers, or charts with contaminated gloves; remove gloves and perform hand hygiene first.

  • High-volume evacuation, rubber dams, and proper patient positioning reduce environmental contamination from splash and spatter.

  • Suction lines and traps are managed according to manufacturer and facility protocols to prevent contamination and backflow.

Quick reference

Surface Disinfection and Waste Management

  • Use EPA-registered hospital disinfectants with a tuberculocidal claim for surfaces contaminated with blood or other potentially infectious materials.

  • Follow the manufacturer's contact time; surfaces must remain wet for the full specified time to achieve disinfection.

  • A 1:10 dilution of 5.25% household bleach (about 5000 ppm available chlorine) is prepared fresh daily for blood spills.

  • Clean visible organic material before applying disinfectant because soil interferes with chemical disinfection.

  • Regulated medical waste includes sharps and items saturated with blood or other potentially infectious materials and is placed in red biohazard bags or containers.

  • Sharps containers are closed and replaced when no more than three-quarters full.

  • Disinfectant containers must be labeled and used at the labeled dilution; never mix incompatible chemicals such as bleach and ammonia.

  • State and local regulations may be stricter than federal rules and govern final waste disposal requirements.

Quick reference

Dental Unit Waterlines

  • CDC recommends that water used for non-surgical dental procedures contain no more than 500 CFU/mL of heterotrophic bacteria.

  • Surgical procedures require sterile saline or sterile water delivered through sterile tubing, not standard dental unit water.

  • Flush waterlines for 20-30 seconds between patients and for several minutes at the start of each clinic day, following manufacturer guidance.

  • Water quality is maintained with independent reservoirs, filters, chemical treatment, or combinations of these methods.

  • Monitor dental unit waterline quality according to manufacturer instructions and at intervals established by the facility's written program.

  • Use only sterile, distilled, or otherwise quality-controlled water in independent reservoirs; empty and clean reservoirs per manufacturer instructions.

  • Antiretraction valves and proper equipment maintenance help prevent backflow of patient material into waterlines.

  • Handpiece and air/water syringe lines are flushed after use and before the next patient.

Quick reference

Aerosol Management and Safe Practices

  • High-volume evacuation, rubber dam isolation, and four-handed dentistry reduce aerosol and splatter generation during restorative and hygiene procedures.

  • A preprocedural mouth rinse with an antimicrobial agent may reduce the microbial load in generated aerosols but does not replace PPE or ventilation.

  • Use an N95 or higher-level respirator, fit-tested, when aerosol-generating procedures are performed on patients with suspected or confirmed airborne infection.

  • Patients with known or suspected airborne infectious disease should have elective aerosol-generating care deferred until the infection risk is resolved.

  • Aerosols and splatter can contaminate nearby surfaces and the operator's PPE; barriers and surface disinfection after treatment are required.

  • Appropriate room ventilation and air filtration, along with adequate air changes per hour, reduce airborne microbial concentrations.

  • Dental health-care personnel should maintain recommended immunizations, including hepatitis B, and follow facility respiratory protection programs.

  • Minimize unnecessary use of ultrasonic scalers and high-speed handpieces when alternatives are appropriate, and always combine them with high-volume evacuation.