  • DC adopts the International Plumbing Code as the DC Plumbing Code; the DC Construction Codes Supplement contains local amendments that override the model text where they conflict.

  • Permits are required for new plumbing, alterations, replacements, and repairs except minor work such as stopping leaks, clearing stoppages, or replacing exposed fixture fittings.

  • A permit expires if work does not start within 180 days of issuance or if work is suspended or abandoned for 180 days; extensions must be requested in writing.

  • Inspections follow a sequence: rough-in (before concealment), underground, and final. Concealed work must be inspected before covering or the contractor must expose it for re-inspection.

  • Plumbing work in DC must be performed by a licensed master or journeyman plumber; a master plumber holds the license and a journeyman works under a master.

  • Appeals of code interpretations go to the DC Board of Appeals and Review; code officials may grant alternative materials or methods if equivalent in safety and performance.

  • The code sets minimum fixture clearances: 15 inches from a wall or partition to the centerline of a water closet, and 30 inches minimum width for the fixture space.

  • Local amendments commonly tighten requirements for backflow protection, lead-free materials, and water conservation beyond the model code minimums.

Quick reference

General Plumbing Knowledge

  • Water weighs 62.4 lb per cubic foot; one cubic foot equals 7.48 gallons, and one gallon weighs 8.34 lb.

  • Static pressure equals 0.433 psi per foot of elevation (2.31 feet of head per psi); pressure increases 0.433 psi for every foot of depth below the source.

  • A water column of 1 psi corresponds to 2.31 feet of height; a 10-foot column produces about 4.33 psi.

  • Flow rate through a pipe relates to velocity by Q = A × V; doubling diameter quadruples cross-sectional area and roughly quarters velocity at the same flow.

  • Drainage pipes flow by gravity at partial capacity; design slope is typically 1/4 inch per foot for pipes 2 1/2 inches and smaller and 1/8 inch per foot for 3 inches and larger.

  • A trap seal is 2 to 4 inches deep; the trap seal depth is measured from the trap weir to the top of the trap dip.

  • Vent stacks relieve pressure differences; a vent's job is to protect the trap seal by equalizing pressure on both sides of the trap.

  • Water hammer is controlled by arrestors or air chambers placed near quick-closing valves; thermal expansion in a closed system requires an expansion tank.

Quick reference

Materials, Fixtures

  • Potable water pipe must be lead-free: the wetted surface of pipe, fittings, and solder may not exceed a weighted average of 0.25 percent lead.

  • Solder for potable water is lead-free tin-antimony or tin-copper; 50/50 tin-lead solder is prohibited on potable systems.

  • PVC and CPVC are joined with solvent cement matched to the pipe; ABS uses ABS cement; never mix cement types across materials.

  • Copper tube is designated by type: K (thickest, underground), L (standard), M (thin wall, above ground, not for underground).

  • Cast iron soil pipe is joined with hub-and-spigot or no-hub couplings; no-hub couplings require a torque wrench set to the manufacturer's value.

  • PEX is joined by crimp, clamp, or expansion fittings; each fitting system must be used with its matching tool and manufacturer-approved components.

  • Water closets are rated in gallons per flush; DC follows the federal 1.6 gpf maximum for tank-type toilets, and urinals are limited to 1.0 gpf.

  • Fixtures must bear the certification mark of an approved testing agency such as ASME, CSA, or IAPMO.

Quick reference

Water Supply and Distribution Systems

  • Minimum residual pressure is 8 psi at a fixture outlet under flow, 15 psi at a sink faucet, and 20 psi at a flushometer valve.

  • Static pressure above 80 psi requires a pressure-reducing valve; the valve must be installed with a strainer and be accessible.

  • Sizing uses fixture units from tables; a 3/4-inch service typically serves a single-family dwelling while larger demands require calculated sizing.

  • Hot water distribution should keep the hot source close to fixtures; long runs require recirculation or a demand-initiated pump to limit wait time and waste.

  • A water service must be protected against backflow by an approved device, and a thermal expansion tank is required on a closed system with a backflow preventer or PRV.

  • Pipe support spacing depends on material: copper horizontal runs are supported about every 6 feet for 1-inch and smaller, plastic per manufacturer and code table.

  • Water supply lines must be protected from freezing; in DC, bury depth and insulation must account for the local frost line.

  • Shutoff valves are required on the fixture supply to each water heater, and a full-open valve on the cold inlet to the water heater.

Quick reference

Drainage, Waste, and Vent Systems

  • Every fixture except a listed exception must have a trap; a trap must be liquid-sealed and protected from siphonage, backpressure, and evaporation.

  • A vent must rise vertically at least 6 inches above the fixture's flood-level rim before offsetting horizontally.

  • The developed length of a fixture trap arm is limited by pipe size: 42 inches for 1 1/2-inch, 60 inches for 2-inch, and 72 inches for 3-inch pipe.

  • A building drain is the lowest piping that receives soil and waste inside the building; it becomes the building sewer 30 inches outside the building wall.

  • Cleanouts are required at the base of each stack, at the building sewer, at changes of direction over 45 degrees, and every 100 feet of horizontal drain.

  • Vent terminals must extend at least 6 inches above the roof and be at least 10 feet from a window, door, or air intake, or 2 feet above it.

  • A wet vent may serve a lavatory and water closet in a bathroom group where allowed; the wet-vented pipe must be sized per the vent tables.

  • Horizontal drainage pipe changes from vertical to horizontal with a long-turn fitting or a combination wye and eighth-bend to keep flow smooth.

Quick reference

Fixtures, Fixture Fittings, and Water Heaters

  • Water heaters require a temperature and pressure relief valve with a discharge pipe that terminates within 6 inches of the floor and does not connect to the drainage system.

  • A T&P relief valve is rated by Btu input and must match or exceed the heater's rating; the discharge pipe must be the same size as the valve outlet.

  • Gas-fired water heaters need a draft hood or draft control and a flue sized to the appliance; the vent connector must slope upward to the chimney.

  • Water heater drain pans are required where leakage would cause damage; the pan must have a drain to an approved location.

  • A water closet must be set level with a wax ring or approved gasket and secured with a closet flange; the flange must be anchored to the floor.

  • Fixture fittings such as faucets must be installed with access for repair; shower valves must have anti-scald protection limiting hot water temperature.

  • Temperature of hot water delivered to fixtures should be limited to 110°F at public lavatories and bathtubs to prevent scalding.

  • Floor drains require a trap primer where the trap could evaporate; primer connections must be protected against backflow.

Quick reference

Fuel Gas Piping and Gas-Fired Appliances

  • Gas piping must be sized per the code's tables based on Btu input, length of run, and specific gravity of the gas; natural gas is about 0.60 specific gravity.

  • Gas pipe must be supported at intervals per code and protected from physical damage; exposed piping must be at least 6 inches above grade.

  • A shutoff valve is required within 6 feet of the appliance and must be accessible; a union or approved disconnect must be provided for removal.

  • Gas piping must be tested with air or inert gas at a pressure of at least 1 1/2 times the working pressure, but not less than 3 psi, for the required duration.

  • Combustion air must be provided to gas appliances; confined spaces require two openings sized per the code or a direct-vent arrangement.

  • A sediment trap must be installed downstream of the appliance shutoff valve, and the appliance connector must be listed and not concealed.

  • Gas-fired appliances must be vented to the outdoors; a vent connector must not be smaller than the appliance draft hood outlet.

  • Leak detection uses soap solution, never an open flame; a gas odorant is added to natural gas so leaks are detectable.

Quick reference

Backflow Prevention, Cross-Connection Control, and Potable Water Protection

  • A cross-connection is any actual or potential connection between potable water and a source of contamination; it must be eliminated or protected by an approved backflow preventer.

  • An air gap is the best protection; it must be at least twice the diameter of the supply pipe and never less than 1 inch above the flood-level rim.

  • A reduced pressure zone (RPZ) assembly provides protection against both backsiphonage and backpressure and requires annual testing and certification.

  • A double check valve assembly protects against backpressure and backsiphonage for low-hazard connections, but not against contaminants that are toxic.

  • A pressure vacuum breaker protects against backsiphonage only and must be installed at least 12 inches above the highest downstream outlet.

  • A hose bibb vacuum breaker is required on sill cocks where a hose can be attached; it protects against backsiphonage at the fixture.

  • Backflow preventers must be tested at installation and annually by a certified tester; test reports are submitted to the water authority.

  • Irrigation systems, boilers, and chemical injection systems require an approved backflow assembly matched to the hazard level.

Quick reference

Safety, Tools, and Job-Site Practices

  • Before trenching, call 811 for utility locates; trenches 5 feet or deeper require protective systems such as shoring, sloping, or a trench box.

  • Confined spaces require atmospheric testing and a permit before entry; gas-fired equipment must never be operated in an unvented enclosed space.

  • Soldering requires fire watch and a fire extinguisher; remove combustibles and use a heat shield when working near framing.

  • Personal protective equipment for plumbing includes safety glasses, gloves, hearing protection, and a respirator when cutting cast iron or working with solvent cement.

  • Solvent cement and primers are flammable and must be used with ventilation; store in a closed container away from ignition sources.

  • Hand tools include a pipe wrench, tubing cutter, and flaring tool; a pipe wrench is directional and must be pulled toward the user for control.

  • Lockout/tagout applies when servicing equipment with energy sources; isolate and tag before repair of pumps or water heaters.

  • Job-site housekeeping prevents slips and falls; keep walkways clear and secure ladders at a 4:1 ratio of height to base distance.