DC Water Operator study materials
DC Water Operator study resources

DC Water Operator cheat sheet

DC Water Operator · Keep the key ideas within reach.

Quick reference

Water Treatment

  • Disinfection CT = disinfectant residual concentration (mg/L) × contact time (min); required CT depends on pH, temperature, and disinfectant type.

  • Chlorine demand = applied dose − residual after contact period; free chlorine residual = total chlorine − combined chlorine.

  • Conventional treatment sequence: coagulation → flocculation → sedimentation → filtration → disinfection.

  • Filter loading rate = flow (gpm) ÷ filter area (ft²); rapid sand filters typically run 2–6 gpm/ft² at design rate.

  • Upflow through a filter bed loosens media, so backwash flow rates are set by percent bed expansion (typically 15–25%) and water temperature.

  • Jar test results set coagulant dose and pH; optimum pH and dose are chosen where settled turbidity is lowest.

  • Turbidity is reported in NTU; combined filter effluent limits are commonly 0.3 NTU in at least 95% of monthly samples and never above 1 NTU.

  • Log removal credit: 1-log = 90%, 2-log = 99%, 3-log = 99.9%, 4-log = 99.99% reduction of pathogens.

  • Fluoride is dosed to about 0.7 mg/L; the MCL is 4.0 mg/L and the secondary standard is 2.0 mg/L.

Quick reference

Water Distribution

  • Pressure = 0.433 psi per foot of water column; 1 psi = 2.31 ft of head.

  • Flow in a full pipe: Q = A × V; for a circular pipe, A = 0.7854 × D².

  • Hazen-Williams head loss hf = 10.44 × L × Q^1.85 ÷ (C^1.85 × d^4.87) in US customary units.

  • Minimum residual disinfectant in the distribution system is typically 0.2 mg/L for free chlorine; detectable residual is required at all points.

  • Minimum normal operating pressure is generally 20 psi; below that, a boil-water notice and investigation are triggered.

  • Water main disinfection after repair commonly uses 25–50 mg/L free chlorine for 24 hours or an equivalent CT.

  • Distribution storage must maintain turnover; long detention time raises water age, which depletes residual and increases DBPs.

  • Cross-connection control relies on backflow prevention by air gap (highest protection) or reduced-pressure-zone assembly.

  • Leak detection: acoustic listening and correlators locate leaks; minimum night flow indicates the size of system losses.

Quick reference

Wastewater Treatment

  • BOD5 measures biodegradable organic matter consumed by microbes over 5 days at 20°C; CBOD excludes nitrogenous demand.

  • Secondary clarifier solids loading rate = (Q + Qr) × MLSS ÷ clarifier area.

  • Sludge age (SRT) = mass of solids in aeration basin ÷ mass of solids wasted per day.

  • F/M ratio = pounds of BOD applied per day ÷ pounds of MLSS in the aeration tank.

  • Return activated sludge rate Qr = Q × MLSS ÷ (RAS concentration − MLSS).

  • Hydraulic detention time = tank volume ÷ flow rate; typical aeration basin detention is 4–8 hours.

  • Nitrification consumes about 4.57 mg O2 per mg N oxidized; denitrification recovers roughly 2.86 mg O2 per mg N.

  • Effluent limits are commonly 30 mg/L BOD and 30 mg/L TSS for secondary treatment, with 85% removal of both.

  • Sludge volume index SVI = settled sludge volume (mL/L after 30 min) × 1,000 ÷ MLSS (mg/L); SVI of 80–150 indicates good settling.

Quick reference

Wastewater Collection

  • Manning's equation: V = (1.486/n) × R^(2/3) × S^(1/2) in US customary units.

  • Self-cleansing velocity in gravity sewers is about 2 ft/s at design flow; below that, solids deposit.

  • Maximum design velocity is typically 10 ft/s to limit scour and hydrogen sulfide release.

  • Minimum sewer slope for an 8-inch line is commonly 0.4% (about 0.0033 ft/ft); smaller pipes need steeper grades.

  • Infiltration enters through defects in pipe and joints; inflow enters through direct connections such as roof drains and sumps.

  • Surcharging occurs when flow exceeds pipe capacity; the hydraulic grade line rises above the crown.

  • Hydrogen sulfide in sewers causes odor and corrosion; it is controlled by ventilation, chemical addition, and preventing septic conditions.

  • Confined-space entry requires atmospheric testing for oxygen (19.5–23.5%), flammables, and H2S before and during entry.

  • Lift station wet-well level controls pump cycling; excessive cycles per hour shorten pump and motor life.

Quick reference

Water Treatment

  • Disinfection CT = disinfectant residual concentration (mg/L) × contact time (min); required CT depends on pH, temperature, and disinfectant type.

  • Chlorine demand = applied dose − residual after contact period; free chlorine residual = total chlorine − combined chlorine.

  • Conventional treatment sequence: coagulation → flocculation → sedimentation → filtration → disinfection.

  • Filter loading rate = flow (gpm) ÷ filter area (ft²); rapid sand filters typically run 2–6 gpm/ft² at design rate.

  • Upflow through a filter bed loosens media, so backwash flow rates are set by percent bed expansion (typically 15–25%) and water temperature.

  • Jar test results set coagulant dose and pH; optimum pH and dose are chosen where settled turbidity is lowest.

  • Turbidity is reported in NTU; combined filter effluent limits are commonly 0.3 NTU in at least 95% of monthly samples and never above 1 NTU.

  • Log removal credit: 1-log = 90%, 2-log = 99%, 3-log = 99.9%, 4-log = 99.99% reduction of pathogens.

  • Fluoride is dosed to about 0.7 mg/L; the MCL is 4.0 mg/L and the secondary standard is 2.0 mg/L.

Quick reference

Water Distribution

  • Pressure = 0.433 psi per foot of water column; 1 psi = 2.31 ft of head.

  • Flow in a full pipe: Q = A × V; for a circular pipe, A = 0.7854 × D².

  • Hazen-Williams head loss hf = 10.44 × L × Q^1.85 ÷ (C^1.85 × d^4.87) in US customary units.

  • Minimum residual disinfectant in the distribution system is typically 0.2 mg/L for free chlorine; detectable residual is required at all points.

  • Minimum normal operating pressure is generally 20 psi; below that, a boil-water notice and investigation are triggered.

  • Water main disinfection after repair commonly uses 25–50 mg/L free chlorine for 24 hours or an equivalent CT.

  • Distribution storage must maintain turnover; long detention time raises water age, which depletes residual and increases DBPs.

  • Cross-connection control relies on backflow prevention by air gap (highest protection) or reduced-pressure-zone assembly.

  • Leak detection: acoustic listening and correlators locate leaks; minimum night flow indicates the size of system losses.

Quick reference

Wastewater Treatment

  • BOD5 measures biodegradable organic matter consumed by microbes over 5 days at 20°C; CBOD excludes nitrogenous demand.

  • Secondary clarifier solids loading rate = (Q + Qr) × MLSS ÷ clarifier area.

  • Sludge age (SRT) = mass of solids in aeration basin ÷ mass of solids wasted per day.

  • F/M ratio = pounds of BOD applied per day ÷ pounds of MLSS in the aeration tank.

  • Return activated sludge rate Qr = Q × MLSS ÷ (RAS concentration − MLSS).

  • Hydraulic detention time = tank volume ÷ flow rate; typical aeration basin detention is 4–8 hours.

  • Nitrification consumes about 4.57 mg O2 per mg N oxidized; denitrification recovers roughly 2.86 mg O2 per mg N.

  • Effluent limits are commonly 30 mg/L BOD and 30 mg/L TSS for secondary treatment, with 85% removal of both.

  • Sludge volume index SVI = settled sludge volume (mL/L after 30 min) × 1,000 ÷ MLSS (mg/L); SVI of 80–150 indicates good settling.

Quick reference

Wastewater Collection

  • Manning's equation: V = (1.486/n) × R^(2/3) × S^(1/2) in US customary units.

  • Self-cleansing velocity in gravity sewers is about 2 ft/s at design flow; below that, solids deposit.

  • Maximum design velocity is typically 10 ft/s to limit scour and hydrogen sulfide release.

  • Minimum sewer slope for an 8-inch line is commonly 0.4% (about 0.0033 ft/ft); smaller pipes need steeper grades.

  • Infiltration enters through defects in pipe and joints; inflow enters through direct connections such as roof drains and sumps.

  • Surcharging occurs when flow exceeds pipe capacity; the hydraulic grade line rises above the crown.

  • Hydrogen sulfide in sewers causes odor and corrosion; it is controlled by ventilation, chemical addition, and preventing septic conditions.

  • Confined-space entry requires atmospheric testing for oxygen (19.5–23.5%), flammables, and H2S before and during entry.

  • Lift station wet-well level controls pump cycling; excessive cycles per hour shorten pump and motor life.

Quick reference

Water Treatment

  • Disinfection CT = disinfectant residual concentration (mg/L) × contact time (min); required CT depends on pH, temperature, and disinfectant type.

  • Chlorine demand = applied dose − residual after contact period; free chlorine residual = total chlorine − combined chlorine.

  • Conventional treatment sequence: coagulation → flocculation → sedimentation → filtration → disinfection.

  • Filter loading rate = flow (gpm) ÷ filter area (ft²); rapid sand filters typically run 2–6 gpm/ft² at design rate.

  • Upflow through a filter bed loosens media, so backwash flow rates are set by percent bed expansion (typically 15–25%) and water temperature.

  • Jar test results set coagulant dose and pH; optimum pH and dose are chosen where settled turbidity is lowest.

  • Turbidity is reported in NTU; combined filter effluent limits are commonly 0.3 NTU in at least 95% of monthly samples and never above 1 NTU.

  • Log removal credit: 1-log = 90%, 2-log = 99%, 3-log = 99.9%, 4-log = 99.99% reduction of pathogens.

  • Fluoride is dosed to about 0.7 mg/L; the MCL is 4.0 mg/L and the secondary standard is 2.0 mg/L.

Quick reference

Water Distribution

  • Pressure = 0.433 psi per foot of water column; 1 psi = 2.31 ft of head.

  • Flow in a full pipe: Q = A × V; for a circular pipe, A = 0.7854 × D².

  • Hazen-Williams head loss hf = 10.44 × L × Q^1.85 ÷ (C^1.85 × d^4.87) in US customary units.

  • Minimum residual disinfectant in the distribution system is typically 0.2 mg/L for free chlorine; detectable residual is required at all points.

  • Minimum normal operating pressure is generally 20 psi; below that, a boil-water notice and investigation are triggered.

  • Water main disinfection after repair commonly uses 25–50 mg/L free chlorine for 24 hours or an equivalent CT.

  • Distribution storage must maintain turnover; long detention time raises water age, which depletes residual and increases DBPs.

  • Cross-connection control relies on backflow prevention by air gap (highest protection) or reduced-pressure-zone assembly.

  • Leak detection: acoustic listening and correlators locate leaks; minimum night flow indicates the size of system losses.

Quick reference

Wastewater Treatment

  • BOD5 measures biodegradable organic matter consumed by microbes over 5 days at 20°C; CBOD excludes nitrogenous demand.

  • Secondary clarifier solids loading rate = (Q + Qr) × MLSS ÷ clarifier area.

  • Sludge age (SRT) = mass of solids in aeration basin ÷ mass of solids wasted per day.

  • F/M ratio = pounds of BOD applied per day ÷ pounds of MLSS in the aeration tank.

  • Return activated sludge rate Qr = Q × MLSS ÷ (RAS concentration − MLSS).

  • Hydraulic detention time = tank volume ÷ flow rate; typical aeration basin detention is 4–8 hours.

  • Nitrification consumes about 4.57 mg O2 per mg N oxidized; denitrification recovers roughly 2.86 mg O2 per mg N.

  • Effluent limits are commonly 30 mg/L BOD and 30 mg/L TSS for secondary treatment, with 85% removal of both.

  • Sludge volume index SVI = settled sludge volume (mL/L after 30 min) × 1,000 ÷ MLSS (mg/L); SVI of 80–150 indicates good settling.

Quick reference

Wastewater Collection

  • Manning's equation: V = (1.486/n) × R^(2/3) × S^(1/2) in US customary units.

  • Self-cleansing velocity in gravity sewers is about 2 ft/s at design flow; below that, solids deposit.

  • Maximum design velocity is typically 10 ft/s to limit scour and hydrogen sulfide release.

  • Minimum sewer slope for an 8-inch line is commonly 0.4% (about 0.0033 ft/ft); smaller pipes need steeper grades.

  • Infiltration enters through defects in pipe and joints; inflow enters through direct connections such as roof drains and sumps.

  • Surcharging occurs when flow exceeds pipe capacity; the hydraulic grade line rises above the crown.

  • Hydrogen sulfide in sewers causes odor and corrosion; it is controlled by ventilation, chemical addition, and preventing septic conditions.

  • Confined-space entry requires atmospheric testing for oxygen (19.5–23.5%), flammables, and H2S before and during entry.

  • Lift station wet-well level controls pump cycling; excessive cycles per hour shorten pump and motor life.