DE Plumber key terms
DE Plumber · Get comfortable with the vocabulary.
- Drainage fixture unit (DFU)
- Related: Fixture branch, Vent stack, Building drain
A number that rates how much wastewater a fixture produces compared with a standard fixture, used to size drain pipes and vents so the system carries the expected load.
- Water supply fixture unit (WSFU)
- Related: Fixture branch, Pressure-reducing valve
A number that estimates the likely peak demand a fixture places on the water supply system, accounting for how often it is used, used to size supply piping.
- Trap seal
- Related: P-trap, Vent stack, Air admittance valve
The measured depth of water held in a plumbing trap that blocks sewer gas from entering a building; it is lost through evaporation or siphonage if the trap is improperly vented.
- P-trap
- Related: Trap seal, Fixture branch
A U-shaped fitting beneath or near a fixture that holds water to seal out sewer gas while allowing wastewater to pass through to the drain.
- Vent stack
- Related: Trap seal, Air admittance valve, Drainage fixture unit (DFU)
A vertical pipe that lets air into the drainage system and releases sewer gas above the roof, protecting trap seals from siphonage and allowing drains to flow smoothly.
- Air admittance valve (AAV)
- Related: Vent stack, Trap seal
A one-way valve installed on a vent line that admits air when a fixture drains and closes to keep sewer gas inside, often used where a full vent stack is impractical.
- Fixture branch
- Related: Drainage fixture unit (DFU), Soil stack
The pipe that connects one or more fixtures to a soil or waste stack, sized by the fixture units it serves and required to be vented.
- Soil stack
- Related: Fixture branch, Building drain, Vent stack
The main vertical pipe that carries wastewater and sewage from fixtures down to the building drain, extending upward to connect with the vent system.
- Building drain
- Related: Building sewer, Soil stack
The lowest horizontal piping of a drainage system that receives waste from stacks and branches and carries it to the building sewer.
- Building sewer
- Related: Building drain, Backwater valve
The pipe that carries sewage from the building drain to the public sewer or private disposal system, starting outside the building foundation.
- Backwater valve
- Related: Building sewer, Cleanout
A one-way valve installed on a drainage line that closes automatically to stop sewage from flowing backward into a building during a sewer backup.
- Cleanout
- Related: Building drain, Backwater valve
An accessible fitting with a removable cap that lets a plumber rod or snake a drain line to clear blockages.
- Water hammer
- Related: Water hammer arrestor, Pressure-reducing valve
A banging or knocking noise and pressure surge caused when flowing water is stopped suddenly, often controlled with air chambers or arrestors.
- Water hammer arrestor
- Related: Water hammer
A device containing a trapped air cushion that absorbs the pressure surge when a valve closes quickly, preventing banging and pipe damage.
- Pressure-reducing valve (PRV)
- Related: Thermal expansion, Water hammer
A device that lowers incoming water pressure to a safe level for the building's piping and fixtures, protecting them from excessive stress.
- Thermal expansion
- Related: Temperature and pressure relief valve, Pressure-reducing valve
The increase in water volume as it is heated in a closed system, which raises pressure and must be relieved by an expansion tank or relief valve.
- Temperature and pressure relief valve (T&P valve)
- Related: Thermal expansion, Backflow prevention device
A safety valve on a water heater that opens to release water if temperature or pressure inside the tank becomes dangerously high.
- Backflow prevention device
- Related: Cross-connection, Air gap
A valve or assembly that stops contaminated water from flowing backward into the potable water supply, protecting drinking water from pollution.
- Cross-connection
- Related: Backflow prevention device, Air gap
Any actual or potential link between the potable water supply and a source of contamination that could allow pollutants to enter drinking water.
- Air gap
- Related: Cross-connection, Backflow prevention device
The unobstructed vertical distance between a water supply outlet and the flood-level rim of a fixture, providing the strongest form of backflow protection.
- Flood-level rim
- Related: Air gap
The edge of a fixture over which water would overflow onto the floor, used as the reference point for setting air gaps and fixture outlet heights.
- Wet vent
- Related: Vent stack, Fixture branch
A vent pipe that also serves as a drain for fixtures on a floor above, allowed only under specific code conditions and sizing limits.
- Developed length
- Related: Slope (fall), Building drain
The total length of pipe measured along its centerline including all fittings and bends, used to determine drain slope and vent sizing.
- Slope (fall)
- Related: Developed length, Building drain
The downward pitch of a horizontal drain pipe, usually expressed in inches per foot, that lets wastewater flow by gravity without clogging.
- Water closet
- Related: Trap seal, Drainage fixture unit (DFU)
The plumbing code term for a toilet; a fixture that receives human waste and discharges it through a trap into the drainage system.
- Potable water
- Related: Cross-connection, Backflow prevention device
Water that is safe for drinking, cooking, and personal use because it meets health standards for contamination and quality.
- Permit
- Related: Inspection, Certificate of occupancy
Official authorization from the local authority to perform plumbing work, required before installation so the work can be inspected and approved.
- Rough-in
- Related: Inspection, Permit
The stage of construction when pipes, drains, and vents are installed inside walls and floors before fixtures and finished surfaces are put in place.
- Inspection
- Related: Rough-in, Permit
A required visit by a code official to examine plumbing work at set stages, such as rough-in and final, to confirm it meets code before it is covered or used.
- Certificate of occupancy
- Related: Inspection, Permit
A document issued by the local authority confirming a building or space may legally be occupied, typically issued after final plumbing inspections pass.
- Lockout/tagout
- Related: Personal protective equipment (PPE), Confined space
A safety procedure that isolates energy sources and applies locks and tags so equipment cannot be started while a worker is servicing it.
- Personal protective equipment (PPE)
- Related: Lockout/tagout, Confined space
Gear such as gloves, safety glasses, respirators, and boots worn to protect a worker from hazards on the job site.
- Confined space
- Related: Lockout/tagout, Personal protective equipment (PPE)
An area with limited entry and exit that is not designed for continuous occupancy and may contain hazardous gases or low oxygen, requiring special safety procedures.
- Material Safety Data Sheet (SDS)
- Related: Personal protective equipment (PPE)
A document that describes the hazards, safe handling, and emergency measures for a chemical product used on the job.
- Change order
- Related: Bid, Punch list
A written agreement that modifies the scope, price, or schedule of a construction contract after work has begun.
- Punch list
- Related: Change order, Certificate of occupancy
A list of incomplete or defective items identified near the end of a project that the contractor must correct before final payment and acceptance.
- Bid
- Related: Change order, Retainage
A contractor's formal offer to perform specified work at a stated price, based on plans, specifications, and estimated labor and material costs.
- Retainage
- Related: Bid, Punch list
A percentage of each payment withheld by the owner until the project is substantially complete, protecting the owner against unfinished or defective work.
- Lien
- Related: Retainage, Change order
A legal claim against a property for unpaid work or materials, which a contractor or supplier can file to secure payment.