National Home Inspector Examination® (NHIE) flashcards
NHIE · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Differential settlement
- Uneven downward movement of a foundation caused by varying soil bearing capacity or moisture. Indicators include diagonal cracks at corners and cracks with offset or displacement.
- Joist notch limit
- In dimensional lumber, notches are allowed only in the top third of the joist, no deeper than one-sixth of the joist depth, and never in the middle third of the span.
- Joist bored hole limit
- Holes must not exceed one-third of the joist depth in diameter, must be at least 2 inches from the top and bottom edges, and must not be within 2 inches of a notch.
- Rafter tie function
- A horizontal member connecting opposing rafters at the wall plate that resists outward thrust. Missing or raised ties can allow walls to spread under roof load.
- Ledger board flashing
- Metal flashing must be installed over the deck ledger and behind the siding to shed water. Missing flashing causes hidden rot at the rim joist and is a common deck failure cause.
- Chimney height rule
- A masonry chimney must extend at least 3 feet above the roof at its highest penetration and at least 2 feet above any roof surface within 10 feet horizontally.
- Load path continuity
- The route by which building loads travel from roof to foundation. Breaks in the path, such as a beam not bearing on a post, are structural concerns to report.
- Collar tie location
- A horizontal member in the upper third of opposing rafters that reduces rafter span and deflection. Absent or loose collar ties in an attic are reportable framing conditions.
- GFCI required locations
- Ground-fault protection is required in bathrooms, kitchens, garages, unfinished basements, outdoors, crawl spaces, and near sinks and laundry areas. Test using the device test/reset button.
- Open ground reading
- A three-light receptacle tester showing an open ground means the grounding conductor is missing or disconnected. The circuit is ungrounded and should be evaluated by an electrician.
- Double-tapped breaker
- Two conductors connected under a single breaker terminal not listed for two conductors. This is a reportable panel defect because of overheating and loose connection risk.
- TPR discharge pipe
- The water heater temperature-pressure relief valve discharge must terminate within 6 inches of the floor or to the exterior, match the valve outlet diameter, and never be capped or reduced.
- Flue slope requirement
- A furnace or water heater flue must slope upward toward the chimney at least one-quarter inch per foot so combustion gases vent properly and condensation does not collect.
- Backdrafting
- Combustion gases spilling from a draft hood into the room rather than up the flue. Detected by flame disturbance or a mirror at the hood; indicates unsafe venting.
- Gas connector rules
- Flexible gas appliance connectors must be listed, must not pass through walls, floors, or ceilings, must not be concealed, and require a shutoff valve in the same room.
- Polybutylene piping
- A gray or blue plastic supply pipe used from the late 1970s to the mid-1990s. It is prone to failure at fittings and is reported as a material with elevated leak risk.
- Dryer vent length limit
- Smooth metal duct is limited to about 25 feet of developed length for a 4-inch duct, reduced 5 feet per 90-degree elbow, and must terminate outdoors with a damper.
- Service panel bonding
- The panel enclosure and grounding electrode conductor must be bonded so fault current has a path to ground. Missing bonding straps or loose lugs are reportable conditions.
- Cracked heat exchanger
- A breach in the furnace heat exchanger that can allow carbon monoxide into supply air. Visible cracks, rust streaks, or flame roll-out warrant shutdown and licensed evaluation.
- Visual inspection scope
- A home inspection is a non-invasive visual examination of readily accessible systems and components. It is not a code inspection, warranty, or technically exhaustive evaluation.
- Material defect
- A condition with a significant adverse effect on the value, safety, or desirability of the property, or one not readily observable to an ordinary buyer.
- Report limitations statement
- The report must identify which systems were inspected and which were not, and state why, such as inaccessible, concealed, unsafe, or disclaimed by the client.
- Pre-inspection agreement
- A signed contract before inspection that defines scope, limitations, fee, and dispute resolution. It is the inspector's primary risk-management document and should be conspicuous.
- Conflict of interest rule
- An inspector should not accept compensation from parties with a financial interest in the transaction, nor perform repairs on a property inspected within a set period.
- Standards of Practice
- A published document defining the minimum systems to inspect, the exclusions, and the reporting requirements for an inspection. Inspectors must follow the version adopted by their state.
- Continuing education hours
- Most licensing states require a set number of CE hours per renewal cycle, commonly 16 to 24, along with adherence to a code of ethics and standards of practice.
- Concealed condition
- A system or component hidden from view, such as wiring inside walls or a foundation under a finished floor. It is excluded from the visual inspection and should be disclaimed.
- Report recommendation language
- Findings should be factual and condition-specific, using phrases such as observed, not observed, and recommend evaluation by a licensed contractor, while avoiding guarantees or life predictions.
- Client confidentiality
- Inspection findings belong to the client. Sharing the report with sellers or agents requires client consent, and the inspector should not disclose results to unauthorized parties.
- Fee independence
- The inspector sets fees independently and should not negotiate fees with real estate agents or accept referral-based compensation, because such arrangements compromise the inspector's impartiality.
- Readily accessible
- A system or component that can be observed without moving personal property, dismantling, or using tools beyond normal inspection equipment. Inaccessible areas must be reported as not inspected.
- Good-faith examination
- The standard of care for an inspection: an honest, diligent visual review performed within the agreed scope and limitations, not a guarantee that every defect will be found.