Shared Recovery Station, Two Refrigerants

EPA 609 · Put your knowledge to work in context.

All case studies

Shared Recovery Station, Two Refrigerants

A mobile A/C shop has one recovery station. On Monday a technician recovered R-134a from a 2012 Civic. On Tuesday a 2019 Subaru arrives with a label specifying R-1234yf and a charge of 17.6 oz. The only recovery machine available is labeled 'R-134a only' and its cylinder is a gray DOT cylinder marked R-134a with a current gross weight of 24 lb and tare of 11 lb. The technician also has a brand-new yellow-hose manifold set and an R-1234yf service cart that is out for calibration. The shop's refrigerant identifier is broken. The technician proposes to connect the R-134a machine to the Subaru, pull the charge into the R-134a cylinder, and later 'burn off' the mixed refrigerant at a licensed reclaimer. The service writer wants the car back by 3 p.m.

1. What must the technician verify and set up before any hose is connected to the Subaru, and why is the proposed R-134a recovery plan unacceptable?

Read the worked answer

First identify the refrigerant with a working identifier, not just the label. R-1234yf is a different refrigerant, mildly flammable (A2L), and must be recovered with equipment certified for it, such as SAE J2843 equipment. The R-134a machine and cylinder are not approved for R-1234yf. Using them creates a mixed refrigerant that cannot be reclaimed to specification and may be rejected by the reclaimer. Mixing also contaminates the cylinder, the machine, and future R-134a service. The 'burn off' idea is not a lawful disposal route: venting is prohibited, and a reclaimer may refuse mixed gas. The correct action is to stop, obtain the R-1234yf equipment or send the vehicle to a properly equipped shop, and never connect the R-134a station.

2. What equipment and recordkeeping practices should the shop put in place for R-1234yf service?

Read the worked answer

Use a dedicated recovery machine, hoses, manifold, vacuum pump, and recovery cylinder for R-1234yf, certified to the relevant SAE standard. Add a refrigerant identifier, leak detection suitable for A2L refrigerant, and training. Keep R-134a and R-1234yf cylinders physically separated and labeled, and use fittings that prevent cross-connection. Record refrigerant recovered, cylinder weights, and equipment maintenance. Because R-1234yf is mildly flammable, avoid ignition sources and follow the vehicle maker's service procedures. A calibrated identifier is essential because mislabeled or contaminated systems exist. If the shop cannot justify the investment, it should not accept R-1234yf work rather than improvise.

3. The service writer pressures the technician to 'just get it done.' What are the consequences of proceeding, and what should the technician say?

Read the worked answer

Proceeding would violate the prohibition on venting and the requirement to use certified recovery equipment for the refrigerant being serviced. It would also contaminate a cylinder and machine, possibly making both unusable. Mixed refrigerant cannot be returned to purity by ordinary recycling; disposal may require incineration or specialized reclamation, and the shop could bear the cost. The technician should state that the vehicle requires R-1234yf equipment and that no safe, legal shortcut exists. Offer alternatives: schedule the car for when the cart is calibrated, call another shop, or have the owner authorize the correct equipment. Document the refusal in the ticket.