EPA 609 · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Section 609 certification
The EPA-required credential for technicians who service or repair motor vehicle air conditioning systems; obtained by passing an EPA-approved test and retained by the employer.
Section 608 scope
Covers stationary refrigeration and air conditioning equipment, not motor vehicles. MVAC technicians certify under Section 609 instead, and both programs prohibit knowing venting.
Venting prohibition
Releasing refrigerant to the atmosphere during service is illegal under Section 609. Refrigerant must be recovered before any system component is opened or disconnected.
Refrigerant sales restriction
MVAC refrigerant may be sold only to certified technicians or to persons certifying intent to resell or to use it for a non-MVAC purpose; records must be kept.
SNAP approval
The Significant New Alternatives Policy program determines which refrigerant substitutes are acceptable. Using an unapproved substitute, especially a flammable one, in MVAC is illegal.
Self-sealing small cans
R-134a containers of 2 pounds or less must have self-sealing valves and required warning labels under EPA rules, reducing accidental release during servicing.
R-12 phase-out
CFC-12 is ozone-depleting and can no longer be manufactured or imported for new MVAC use in the U.S.; recovered R-12 may be recycled and reused.
Certification recordkeeping
Employers must keep proof of each technician's Section 609 certification and make it available to EPA on request; technicians should retain a copy.
Recovery cylinder 80% rule
Refillable recovery cylinders must never be filled above 80% of capacity; a scale or float switch must stop transfer at that limit to prevent hydrostatic rupture.
Recovery machine standards
MVAC recovery equipment must be certified to the applicable SAE standard (J2810 for R-134a, J2788 for R-1234yf) and used per manufacturer instructions.
Manifold gauge colors
Blue identifies the low-pressure side, red the high-pressure side, and yellow the center service port used for recovery, evacuation, and charging.
Evacuation target
Evacuate the system to at least 29.9 inches of mercury (about 500 microns) and hold it; a rising vacuum indicates a leak or moisture problem.
Weigh-in charging
Charge refrigerant by weight to the OEM-specified amount using a scale. Pressure alone is unreliable because it changes with ambient temperature and load.
Leak detection methods
Use electronic leak detectors, UV dye, or soap bubbles. Never use an open flame or halide torch, especially on flammable R-1234yf systems.
R-1234yf flammability
R-1234yf is classified A2L, mildly flammable. Service requires no ignition sources, adequate ventilation, and dedicated equipment separate from R-134a.
Coupler mismatch
R-1234yf and R-134a service fittings differ, so equipment cannot be cross-connected; this prevents accidental mixing of the two refrigerants.
Disposable cylinder rule
Single-use refrigerant cylinders must not be refilled or used for recovery; only DOT-approved refillable cylinders may hold recovered refrigerant.
Purging service hoses
Before opening refrigerant flow, purge air from manifold hoses to prevent introducing moisture and non-condensable gas into the system.
Recovery defined
Removing refrigerant from an MVAC system into an external container. Required before opening the system and performed with certified recovery equipment.
Recycling defined
Cleaning recovered refrigerant on-site by removing oil, moisture, and particulates so it can be reused in MVAC systems; does not restore it to resale purity.
Reclamation defined
Processing refrigerant to AHRI 700 purity by an EPA-certified reclaimer; reclaimed refrigerant may be sold or transferred, unlike merely recycled refrigerant.
Separate recovery cylinders
Each refrigerant, such as R-134a and R-1234yf, must be recovered into its own labeled cylinder; mixed refrigerant becomes unreclaimable and may damage equipment.
Recovery efficiency
Certified MVAC recovery equipment must remove at least 90-95% of the charge, depending on the SAE standard and whether the system is running during recovery.
Frostbite hazard
Liquid refrigerant contacting skin causes rapid frostbite; wear gloves and eye protection, and avoid trapping liquid refrigerant against skin or in clothing.
Asphyxiation hazard
Refrigerant vapor is heavier than air and displaces oxygen in enclosed spaces, creating a suffocation risk; service areas need ventilation and leak monitoring.
Economic value of recovery
Recovered refrigerant can be recycled and reused, avoiding purchase of new refrigerant and disposal costs while meeting the legal prohibition on venting.
Ozone depletion potential
A relative measure of a substance's ability to destroy stratospheric ozone. CFC-12 is the reference at 1.0; HFCs such as R-134a have ODP 0.
Global warming potential
A 100-year measure of heat trapping relative to CO2. R-134a is about 1,430, R-1234yf about 4, and R-12 about 10,900.
Chlorine catalysis
Chlorine released from CFCs in the stratosphere catalyzes ozone destruction, so one chlorine atom can destroy thousands of ozone molecules before being removed.
Ozone layer function
Stratospheric ozone absorbs harmful UV-B radiation; its depletion raises skin cancer, cataract, and immune risks and harms crops and marine ecosystems.
R-1234yf climate profile
An HFO refrigerant with GWP about 4 and ODP 0, adopted to cut MVAC climate impact; it is A2L mildly flammable, so ignition sources must be avoided.
Indirect climate effect
Improper charge, leaks, or inefficient operation raise fuel consumption and CO2 emissions, adding climate impact beyond the refrigerant released.