32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Section 609 certification
- The EPA-required credential for technicians who service or repair motor vehicle air conditioning systems; obtained by passing an EPA-approved test and retained by the employer.
- Section 608 scope
- Covers stationary refrigeration and air conditioning equipment, not motor vehicles. MVAC technicians certify under Section 609 instead, and both programs prohibit knowing venting.
- Venting prohibition
- Releasing refrigerant to the atmosphere during service is illegal under Section 609. Refrigerant must be recovered before any system component is opened or disconnected.
- Refrigerant sales restriction
- MVAC refrigerant may be sold only to certified technicians or to persons certifying intent to resell or to use it for a non-MVAC purpose; records must be kept.
- SNAP approval
- The Significant New Alternatives Policy program determines which refrigerant substitutes are acceptable. Using an unapproved substitute, especially a flammable one, in MVAC is illegal.
- Self-sealing small cans
- R-134a containers of 2 pounds or less must have self-sealing valves and required warning labels under EPA rules, reducing accidental release during servicing.
- R-12 phase-out
- CFC-12 is ozone-depleting and can no longer be manufactured or imported for new MVAC use in the U.S.; recovered R-12 may be recycled and reused.
- Certification recordkeeping
- Employers must keep proof of each technician's Section 609 certification and make it available to EPA on request; technicians should retain a copy.
- Recovery cylinder 80% rule
- Refillable recovery cylinders must never be filled above 80% of capacity; a scale or float switch must stop transfer at that limit to prevent hydrostatic rupture.
- Recovery machine standards
- MVAC recovery equipment must be certified to the applicable SAE standard (J2810 for R-134a, J2788 for R-1234yf) and used per manufacturer instructions.
- Manifold gauge colors
- Blue identifies the low-pressure side, red the high-pressure side, and yellow the center service port used for recovery, evacuation, and charging.
- Evacuation target
- Evacuate the system to at least 29.9 inches of mercury (about 500 microns) and hold it; a rising vacuum indicates a leak or moisture problem.
- Weigh-in charging
- Charge refrigerant by weight to the OEM-specified amount using a scale. Pressure alone is unreliable because it changes with ambient temperature and load.
- Leak detection methods
- Use electronic leak detectors, UV dye, or soap bubbles. Never use an open flame or halide torch, especially on flammable R-1234yf systems.
- R-1234yf flammability
- R-1234yf is classified A2L, mildly flammable. Service requires no ignition sources, adequate ventilation, and dedicated equipment separate from R-134a.
- Coupler mismatch
- R-1234yf and R-134a service fittings differ, so equipment cannot be cross-connected; this prevents accidental mixing of the two refrigerants.
- Disposable cylinder rule
- Single-use refrigerant cylinders must not be refilled or used for recovery; only DOT-approved refillable cylinders may hold recovered refrigerant.
- Purging service hoses
- Before opening refrigerant flow, purge air from manifold hoses to prevent introducing moisture and non-condensable gas into the system.
- Recovery defined
- Removing refrigerant from an MVAC system into an external container. Required before opening the system and performed with certified recovery equipment.
- Recycling defined
- Cleaning recovered refrigerant on-site by removing oil, moisture, and particulates so it can be reused in MVAC systems; does not restore it to resale purity.
- Reclamation defined
- Processing refrigerant to AHRI 700 purity by an EPA-certified reclaimer; reclaimed refrigerant may be sold or transferred, unlike merely recycled refrigerant.
- Separate recovery cylinders
- Each refrigerant, such as R-134a and R-1234yf, must be recovered into its own labeled cylinder; mixed refrigerant becomes unreclaimable and may damage equipment.
- Recovery efficiency
- Certified MVAC recovery equipment must remove at least 90-95% of the charge, depending on the SAE standard and whether the system is running during recovery.
- Frostbite hazard
- Liquid refrigerant contacting skin causes rapid frostbite; wear gloves and eye protection, and avoid trapping liquid refrigerant against skin or in clothing.
- Asphyxiation hazard
- Refrigerant vapor is heavier than air and displaces oxygen in enclosed spaces, creating a suffocation risk; service areas need ventilation and leak monitoring.
- Economic value of recovery
- Recovered refrigerant can be recycled and reused, avoiding purchase of new refrigerant and disposal costs while meeting the legal prohibition on venting.
- Ozone depletion potential
- A relative measure of a substance's ability to destroy stratospheric ozone. CFC-12 is the reference at 1.0; HFCs such as R-134a have ODP 0.
- Global warming potential
- A 100-year measure of heat trapping relative to CO2. R-134a is about 1,430, R-1234yf about 4, and R-12 about 10,900.
- Chlorine catalysis
- Chlorine released from CFCs in the stratosphere catalyzes ozone destruction, so one chlorine atom can destroy thousands of ozone molecules before being removed.
- Ozone layer function
- Stratospheric ozone absorbs harmful UV-B radiation; its depletion raises skin cancer, cataract, and immune risks and harms crops and marine ecosystems.
- R-1234yf climate profile
- An HFO refrigerant with GWP about 4 and ODP 0, adopted to cut MVAC climate impact; it is A2L mildly flammable, so ignition sources must be avoided.
- Indirect climate effect
- Improper charge, leaks, or inefficient operation raise fuel consumption and CO2 emissions, adding climate impact beyond the refrigerant released.