EPA Lead Supervisor study materials
EPA Lead Supervisor study resources

EPA Lead Supervisor cheat sheet

EPA Lead Supervisor · Keep the key ideas within reach.

Quick reference

Health Effects and Characteristics of Lead-Based Paint Hazards

  • Lead-based paint is paint or surface coating containing lead at or above 1.0 mg/cm², or 0.5 percent (5,000 ppm) lead by weight.

  • Long-standing dust-lead hazard standards are 10 µg/ft² on floors, 100 µg/ft² on interior window sills, and 400 µg/ft² in window troughs.

  • EPA's 2024 final rule lowered dust-lead hazard standards to 5 µg/ft² (floors) and 40 µg/ft² (interior sills) and clearance levels to 4, 10, and 100 µg/ft² (floors, sills, troughs).

  • Bare soil is a lead hazard at 400 ppm in play areas and 1,200 ppm in other bare soil where children are exposed.

  • Children absorb about 40–50 percent of ingested lead; adults absorb about 10–15 percent, so the same dust loading carries greater child risk.

  • Lead blocks ALA dehydratase and ferrochelatase in the heme pathway, causing anemia, and competes with calcium in nerve and enzyme function.

  • No safe blood lead level in children is known; CDC's blood lead reference value is 3.5 µg/dL.

  • Lead crosses the placenta and damages the developing nervous system; other effects include nephrotoxicity, hypertension, colic, and encephalopathy at high exposure.

  • Deteriorated paint, friction surfaces (windows, doors), impact surfaces, and chewable surfaces are the principal paint-lead hazard pathways.

Quick reference

Federal, State, and Local Regulations and Standards

  • TSCA Title IV (15 U.S.C. 2681–2692) is implemented at 40 CFR Part 745 and authorizes EPA's abatement, certification, and disclosure programs.

  • EPA individual certifications are inspector, risk assessor, abatement supervisor, abatement worker, and project designer; firms must also be certified.

  • The certified firm must notify EPA or the authorized state program in writing at least 5 working days before abatement begins, unless the state requires a longer period.

  • The RRP rule covers pre-1978 target housing and child-occupied facilities when renovation disturbs more than 6 ft² interior or 20 ft² exterior; RRP is not abatement.

  • Pre-renovation education requires delivering the EPA pamphlet 'Protect Your Family from Lead in Your Home' to occupants of pre-1978 housing before work starts.

  • OSHA 29 CFR 1926.62 governs construction lead exposure: PEL 50 µg/m³ and action level 30 µg/m³, both 8-hour time-weighted averages.

  • RCRA classifies lead-bearing waste as hazardous when TCLP leachate is at or above 5 mg/L (toxicity characteristic, waste code D008).

  • EPA-authorized state programs may be stricter than federal rules; where requirements conflict, the more stringent requirement applies.

  • Sellers and lessors of pre-1978 housing must disclose known lead-based paint and hazards, and buyers get a 10-day period to test.

Quick reference

Abatement Methods, Containment, and On-the-Job Supervision

  • Abatement methods are component removal, component replacement, enclosure, encapsulation, surface stripping (on- or off-site), and soil removal or replacement.

  • Containment uses two layers of 6-mil polyethylene on floors, one layer on walls, lapped and taped, with critical barriers sealing doors, windows, HVAC vents, and penetrations.

  • HEPA-filtered negative air machines exhaust outdoors and hold the containment under negative pressure for the duration of abatement.

  • Prohibited practices include open-flame burning, uncontrolled abrasive blasting or dry machine sanding without HEPA exhaust, hydroblasting without containment, and methylene chloride stripping.

  • Heat guns used to strip paint must operate below 1,100 °F to avoid generating lead fume.

  • Encapsulants may be used only on non-friction, non-impact, non-chewable surfaces and only when the product is listed for that substrate and applied per label.

  • A certified supervisor must be physically on site whenever abatement is performed and may direct only trained, certified workers.

  • Workers follow a project-specific work plan; eating, drinking, smoking, and chewing are prohibited inside the work area, and hands and face are washed before breaks.

  • End-of-shift decontamination and daily cleanup are performed before leaving the work area, with debris bagged and the containment re-secured.

Quick reference

Worker Protection, Respiratory Protection, and PPE

  • Exposure above the 30 µg/m³ action level triggers medical surveillance eligibility, and blood lead plus ZPP testing at least every 6 months (every 2 months when BLL is 25 µg/dL or higher).

  • Assigned protection factors: half-mask air-purifying respirator 10, full facepiece 50, powered air-purifying respirator with loose-fitting hood 25.

  • A written respiratory protection program must include medical evaluation, fit testing, training, cartridge change schedules, cleaning and storage, and program evaluation.

  • Medical removal is required when blood lead averages 50 µg/dL or higher; the worker may return to lead work after blood lead falls below 40 µg/dL.

  • PPE for abatement includes disposable coveralls with hood, boot covers, nitrile gloves, and eye protection, removed before leaving the work area.

  • Showers are required when airborne lead exceeds the PEL more than 30 days per year; otherwise wash-up facilities and separate clean change areas are required.

  • Engineering controls come first: HEPA vacuums, wet methods, local exhaust ventilation, and containment keep airborne lead below the PEL.

  • Eating, drinking, smoking, chewing gum, and applying cosmetics are prohibited in the work area; hands and face must be washed before eating or drinking.

  • Respirator use requires a medical clearance and annual fit testing; facial hair at the sealing surface prevents an adequate tight-fitting seal.

Quick reference

Cleanup, Clearance Testing, Waste Disposal, and Recordkeeping

  • Final cleaning proceeds top-down: HEPA vacuum all surfaces, wet wash with detergent, then HEPA vacuum again before clearance sampling.

  • Long-standing clearance levels are 40 µg/ft² on floors, 250 µg/ft² on interior window sills, and 400 µg/ft² in window troughs; EPA's 2024 rule set clearance at 4, 10, and 100 µg/ft².

  • Clearance requires a visual inspection showing no dust, debris, paint chips, or residue, followed by dust wipe sampling by a certified inspector, risk assessor, or clearance technician.

  • The clearance examiner must be independent of the abatement contractor and may not clear a project on which the person performed abatement work.

  • If clearance fails, the area is recleaned and retested; reoccupancy is not permitted until clearance is achieved.

  • Waste goes into sealed, labeled, dust-tight containers (6-mil bags or drums); TCLP testing determines whether the debris is D008 hazardous waste.

  • Hazardous lead waste requires a manifest, a permitted transporter, and a permitted treatment, storage, and disposal facility; loads must be covered in transit.

  • The contractor gives the building owner a written abatement report within 10 days of completion, describing methods, dates, and clearance results.

  • OSHA requires employee exposure and medical records for lead-exposed workers to be retained for 30 years; abatement and certification records are retained per EPA and state schedules.