PCN NDT Radiographic Testing Level 2 Exam flashcards
PCN NDT Radiographic Testing Level 2 Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Inverse square law
- Exposure rate from a point source falls with the square of distance: I1/I2 = (d2/d1)². Doubling the distance reduces the dose rate and the film exposure to one quarter.
- Half value layer
- The thickness of a material that reduces the intensity of a radiation beam to half its original value: HVL = 0.693/μ. It is used in shielding calculations and to describe beam quality.
- Photoelectric absorption
- A photon transfers all its energy to a bound electron, which is ejected. The probability rises steeply with atomic number and falls with photon energy, giving strong contrast at low kilovoltage.
- Geometric unsharpness
- Blurring of the image caused by the finite source size. It is calculated as Ug = F·t/d, where F is the source size, t the object-to-detector distance and d the source-to-object distance.
- Occupational dose limit
- ICRP and IRR17 limit the effective dose to 20 mSv per year averaged over five years, with a maximum of 50 mSv in any single year.
- ALARA principle
- Radiation doses are kept as low as reasonably achievable, taking economic and social factors into account, while still producing radiographs of the required quality.
- Controlled area
- A defined area where radiation dose rates or doses require special protection measures and restricted access. Its boundaries are marked and entry is controlled under local rules.
- Sealed source leak test
- A wipe test of a sealed source, container and guide tube, carried out at intervals not exceeding six months and after any incident, to detect removable radioactive contamination.
- Ir-192 half-life
- 73.8 days. Activity falls by half in that period, so exposure times must be increased regularly and the source replaced when output becomes impractical.
- Bremsstrahlung
- The continuous X-ray spectrum produced when electrons are decelerated in the anode target. Its total intensity increases with target atomic number, tube current and the square of the accelerating voltage.
- Focal spot size
- The area of the anode where electrons strike and X-rays are produced. A smaller focal spot sharpens the image but limits the tube current that can be applied.
- Co-60 gamma energies
- Co-60 emits gamma photons of 1.17 and 1.33 MeV and has a half-life of 5.27 years. Its high penetration suits thick steel sections above about 50 mm.
- Characteristic curve
- A plot of film density against log relative exposure showing fog, toe, a straight-line region of maximum contrast, shoulder and Dmax. It describes film speed and contrast.
- Film density
- D = log10(I0/It), where I0 is the incident light intensity and It is the transmitted intensity. A density of 3.0 means only 0.1% of the light is transmitted.
- Lead intensifying screen
- A thin lead foil placed in contact with the film. It emits electrons that expose the emulsion, reducing exposure time, and it absorbs low-energy scatter.
- Safelight
- Filtered darkroom illumination that does not significantly fog the film during normal handling. Its suitability is confirmed by a safelight test at the specified distance and time.
- Source-to-film distance
- The distance from the radiation source to the film. Increasing SFD reduces geometric unsharpness but increases the exposure time according to the inverse square law.
- Double wall single image
- An exposure technique in which the beam passes through two walls but only the weld nearest the film is imaged. It is used when the pipe bore is inaccessible.
- Technique class B
- The higher sensitivity class of ISO 17636-1, requiring a smaller source size, larger source-to-film distance, higher film density and better image quality indicator values than class A.
- IQI film-side placement
- When the source side is inaccessible, the image quality indicator is placed on the film side and marked with a lead letter F; sensitivity is then affected by the full object thickness.
- IQI sensitivity
- Expressed as a percentage: the diameter of the smallest visible wire divided by the material thickness, multiplied by 100. A lower percentage indicates better sensitivity.
- Duplex wire IQI
- A pair of wire gauges used to measure image unsharpness. The smallest wire pair that can still be resolved indicates the basic spatial resolution of the image.
- Scatter radiation
- Photons deflected or re-emitted within the object, cassette or surroundings. Scatter reduces image contrast and is controlled by collimation, filters, lead masking and screens.
- Total unsharpness
- The combined effect of geometric, film and screen unsharpness, approximated by Ut = (Ug³ + Ui³)^(1/3). The largest individual component dominates the result.
- Lack of penetration
- A root discontinuity appearing as a straight dark line of near-uniform width where weld metal has not fused into the root; it must be distinguished from root concavity.
- Tungsten inclusion
- Dense particles trapped in a TIG weld that appear as bright, sharply defined spots, because tungsten attenuates the beam far more strongly than the surrounding steel.
- Planar discontinuity
- A crack, lack of fusion or lack of penetration lying essentially in one plane. Detection depends strongly on beam angle, and such flaws are often more damaging than rounded porosity.
- Acceptance criteria
- The limits defined by the applicable code, such as ISO 5817 quality levels B to D or ASME UW-51, that decide whether an indicated discontinuity is acceptable or requires repair.
- Technique sheet
- A document recording all exposure parameters for a component: material, thickness, source, source-to-film distance, kilovoltage or activity, exposure time, film, screens and IQI.
- Traceability
- The ability to link a radiograph and its report to the source, film batch, screens, IQI, equipment and calibrated instruments through recorded serial numbers and calibration dates.
- PCN Level 2 validity
- Certification to ISO 9712 is valid for five years. Revalidation is required at the mid-term point and re-certification by examination before the five-year expiry.
- Non-conformance
- A failure to meet a specified requirement. It triggers documented corrective action and, where needed, retest or repair, with all records retained alongside the radiographs and report.