PCN NDT Ultrasonic Testing Level 2 Exam flashcards
PCN NDT Ultrasonic Testing Level 2 Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Acoustic impedance
- The product of material density and sound velocity (Z = ρV); determines reflection and transmission at interfaces. Units are Rayl (kg/m²s).
- Near field length
- For a circular piston transducer, N = D²/(4λ); within this distance the beam is complex and amplitude does not follow inverse square law.
- Beam spread angle
- Half-angle to first null: sin θ = 1.22 λ/D. To −6 dB: sin θ = 0.51 λ/D. Smaller wavelength or larger diameter gives narrower beam.
- Snell's law
- sin θ₁ / sin θ₂ = V₁ / V₂. Used to calculate refracted angle in angle beam testing and to determine critical angles.
- First critical angle
- Incident angle at which refracted longitudinal wave is 90°; beyond it only shear wave propagates. θ = sin⁻¹(V₁/V₂) using longitudinal velocities.
- Second critical angle
- Incident angle at which refracted shear wave is 90°; beyond it total reflection occurs. θ = sin⁻¹(V₁/Vs₂).
- Skip distance
- For angle beam, the surface distance from index point to where the beam first hits the back wall: skip = 2T tan θ, where T is thickness.
- DAC curve
- Distance Amplitude Correction: a curve showing echo amplitude from a reference reflector versus distance, used to compensate for beam spread and attenuation.
- TCG
- Time Corrected Gain: electronic gain that increases with time to flatten the DAC curve, making indications of equal size appear equal amplitude regardless of depth.
- 6 dB drop method
- Sizing technique where probe is moved until echo amplitude falls to half (−6 dB) of maximum; the distance moved approximates flaw length for reflectors larger than beam.
- IIW/V1 block
- Calibration block used to determine index point, refracted angle, and probe resolution; contains a 100 mm radius and a 50 mm hole.
- V2 block
- DIN 54-122 block used for time base and sensitivity calibration; has multiple reflectors at known distances and a 25 mm radius.
- Side-drilled hole
- Reference reflector used in DAC calibration; a cylindrical hole drilled parallel to the surface at a known depth, providing a repeatable indication.
- Flat-bottom hole
- Reference reflector with a flat bottom of known area; used for area linearity and sensitivity calibration, often in ASME blocks.
- Piezoelectric effect
- Property of certain crystals (quartz, PZT) to generate voltage when deformed and to deform when voltage applied; basis of ultrasonic transducers.
- Transducer damping
- Backing material that absorbs rearward waves, shortening pulse duration and improving axial resolution; reduces sensitivity but increases bandwidth.
- Axial resolution
- Ability to separate two reflectors along the beam path; approximately half the spatial pulse length. Shorter pulses (higher damping, higher frequency) improve it.
- Lateral resolution
- Ability to separate two reflectors perpendicular to beam; best at focal point, approximately beam width there. Improved by focusing.
- Couplant
- Material (oil, gel, water) used to transmit ultrasound between transducer and test surface by eliminating air gap; must have acoustic impedance between those of transducer and test material.
- Angle beam probe
- Transducer mounted on a wedge to introduce refracted shear waves into the test piece at a selected angle (e.g., 45°, 60°, 70°).
- Index point
- Point on the wedge where the beam exits; used as reference for surface distance measurements; determined using IIW block.
- Refracted angle
- Angle of the beam in the test material after refraction at interface; measured from normal. Determined by Snell's law and verified on calibration block.
- Attenuation
- Loss of sound energy due to scattering and absorption; increases with frequency and grain size. Compensated by DAC/TCG.
- Acoustic velocity
- Speed of sound in a material; longitudinal velocity in steel ~5900 m/s, shear ~3200 m/s. Depends on elastic modulus and density.
- Wavelength
- λ = V/f. Determines sensitivity and resolution; smaller wavelength (higher frequency) detects smaller flaws but attenuates more.
- Pulse-echo technique
- Method where a single transducer sends and receives pulses; flaw detected by echo between initial pulse and back-wall echo.
- Through-transmission technique
- Two transducers on opposite sides; flaw detected by reduction in transmitted signal. Not sensitive to flaw depth but good for attenuative materials.
- Immersion testing
- Technique where part and transducer are submerged in water; allows precise focusing and scanning; water path must exceed near field in water.
- Reference reflector
- Known artificial flaw (SDH, FBH, notch) used to establish sensitivity and DAC curve; must be in material similar to test piece.
- Transfer correction
- Adjustment made when calibration block material differs from test material; compensates for attenuation and velocity differences.
- Scanning sensitivity
- Gain setting that brings reference reflector echo to a specified screen height (e.g., 80% FSH); ensures consistent detection.
- Indication classification
- Categorizing indications as relevant, non-relevant, or false; based on origin, shape, and response to probe movement.