Extreme Switching Architecture and Hardware Fundamentals

  • ExtremeXOS (EXOS) and Extreme Fabric Engine (VOSS) are distinct operating systems: EXOS is the CLI/OS used on X-series, Summit, and many SLX/Universal platforms; VOSS is the OS on VSP/Fabric Engine platforms and uses a different CLI syntax and configuration model.

  • Stacking on Extreme switches uses SummitStack (EXOS) over dedicated stacking ports or front-panel ports; a stack elects a master and a backup master, and the stack is managed as one logical device with one IP address.

  • Extreme Fabric Connect is a SPB (Shortest Path Bridging, IEEE 802.1aq) based architecture: it uses IS-IS as the control plane, provides MAC-in-MAC encapsulation, and enables L2/L3 virtualization via service instances (VSNs).

  • EXOS hardware families include fixed-configuration Summit switches and modular X-series chassis; line cards and management modules are hot-swappable on supported chassis, and power supplies can be redundant and load-sharing.

  • Port numbering on EXOS is slot:port (e.g., 1:5); on stackable Summit switches the stack port numbering and slot ID are assigned at stack formation, and the slot ID determines the port prefix.

  • Interface types in EXOS include physical ports, LAG (link aggregation group) logical ports, VLAN logical interfaces, and loopback interfaces; routing and management can be bound to these logical interfaces.

  • EXOS supports alternate operating modes and platforms (e.g., EXOS on supported third-party or white-box hardware via Extreme's open networking offerings); feature availability varies by platform and license.

  • A switch's forwarding is hardware (ASIC) based; control-plane functions (STP, routing protocols, management) run in software, so a control-plane overload can disrupt protocols while forwarding continues.

Quick reference

Initial Configuration, Management Access, and Software Updates

  • EXOS initial access is via console (default baud 9600, 8N1); the default login is admin with no password, and the first configuration step should set a password and management IP.

  • Management VLAN/IP is configured with commands such as configure vlan Mgmt ipaddress <ip> <mask> and enable ipforwarding vlan Mgmt; the default management VLAN is typically Mgmt (VLAN 4095 on some platforms).

  • Save configuration with save configuration (or save config); unsaved changes are lost on reboot. Use show configuration to review and upload configuration/download configuration for backup and restore via TFTP/SCP.

  • Software images on EXOS are updated with download image <server> <file> {primary|secondary} then reboot; show version displays the running image, and use image selects the boot image.

  • Management protocols to enable/disable: SSH (enable ssh2), Telnet (disable telnet recommended), SNMP (enable snmp access), and HTTPS (enable web http/enable web https). Restrict access with ACLs on the management VLAN.

  • EXOS supports multiple user accounts with create account <user> <password> {admin|user}; AAA (RADIUS/TACACS+) is configured with configure radius/configure tacacs and configure aaa to authenticate management logins.

  • Configuration modes: EXOS CLI has a User EXEC and Privileged EXEC model; configure terminal is not required - commands are entered directly at the prompt, and show commands display state.

  • NTP is configured with configure ntp server add <ip> and enable ntp; correct time is required for certificate validation, log timestamps, and AAA accounting.

Quick reference

VLANs, Spanning Tree, and Layer 2 Redundancy

  • VLAN creation: create vlan <name> tag <id>; add ports with configure vlan <name> add ports <portlist> {tagged|untagged}. A port can be untagged in only one VLAN; tagged ports carry multiple VLANs.

  • The default VLAN is typically VLAN 1 (named Default); untagged traffic on a port belongs to that port's untagged VLAN. Tagged frames use 802.1Q tags with the configured VLAN ID.

  • EXOS supports STP, RSTP (802.1w), and MSTP (802.1s). Enable with enable stpd <name> and configure mode with configure stpd <name> mode {dot1d|dot1w|mstp}.

  • MSTP maps VLANs to MST instances; configure with configure stpd <name> add vlan <vlan> dot1d <instance>; the region name and revision must match across all switches in the MST region.

  • STP port roles include Root, Designated, Alternate, and Backup; port states are Discarding, Learning, and Forwarding (RSTP/MSTP). Root bridge selection uses bridge priority then MAC address.

  • Edge ports (PortFast equivalent) skip STP listening/learning: configure stpd <name> ports <port> edge-safeguard or edge-port; BPDU guard protects against loops from edge devices.

  • ERPS (G.8032) and Extreme's Ethernet Automatic Protection Switching (EAPS) provide sub-second ring protection as alternatives to STP; EAPS uses a master node and control VLAN to detect ring failure.

  • Root guard and BPDU guard: configure stpd <name> ports <port> root-guard prevents a port from becoming root; BPDU guard disables an edge port that receives BPDUs.

Quick reference

Link Aggregation and Load Sharing

  • LAG creation on EXOS: create lag <name> then configure lag <name> add ports <portlist>; or use enable sharing <master-port> grouping <portlist> algorithm <algo>.

  • Static LAGs require matching configuration on both ends; LACP (802.3ad) uses configure sharing <master> lacp and negotiates aggregation automatically.

  • LACP modes: active (initiates LACP), passive (responds only). At least one side must be active for the LAG to form.

  • Load-sharing algorithms include L2 (source/destination MAC), L3 (source/destination IP), and L4 (TCP/UDP port). Choose an algorithm that matches traffic patterns to avoid polarization.

  • All ports in a LAG must have the same speed, duplex, and VLAN membership; a port can belong to only one LAG, and the master port carries the LAG's configuration.

  • show sharing and show lacp display LAG status, member ports, and LACP neighbor state; show ports <port> info detail shows per-port link and flow control.

  • Multi-switch LAG (MLAG) on EXOS uses Extreme's MLAG or VSS-like features; on Fabric Engine, multi-homing uses SMLT/RSMLT for active-active dual-homed connections.

  • LAG health-check and min-links: configure a minimum number of active links so the LAG goes down if too few members remain, preventing black-holing.

Quick reference

IP Routing and Layer 3 Forwarding on Switches

  • Enable routing globally with enable ipforwarding; create a VLAN interface with configure vlan <name> ipaddress <ip> <mask> and enable enable ipforwarding vlan <name>.

  • Static routes: configure iproute add <network> <mask> <gateway>; default route uses 0.0.0.0/0. show iproute displays the routing table and show iproute <network> shows a specific route.

  • EXOS supports OSPF (v2/v3), BGP, IS-IS, and RIP. OSPF is enabled with enable ospf and areas/interfaces configured via configure ospf add vlan <name> area <id>.

  • VRF (Virtual Routing and Forwarding) separates routing tables: create with create vrf <name> and bind VLANs/interfaces to the VRF; each VRF has independent routing and forwarding.

  • ECMP (Equal-Cost Multi-Path) allows multiple equal-cost routes; EXOS supports ECMP for OSPF/BGP/static routes, and configure iproute add ... metric influences path selection.

  • ARP: show iparp displays the ARP table; clear iparp flushes entries. Proxy ARP can be enabled per VLAN with enable iparp proxy.

  • IPv6 is supported with enable ipforwarding ipv6, configure vlan <name> ipaddress <ipv6>/<prefix>, and configure iproute add <prefix> <gateway> for IPv6 routes.

  • Route redistribution between protocols is configured with configure <protocol> add export <protocol>; use route maps to filter and set attributes.

Quick reference

Network Security, Authentication, and Access Control

  • Port security limits MAC addresses per port: configure ports <port> limit-learned-mac <n> and configure ports <port> lock-learning; violations can disable the port or drop frames.

  • 802.1X authentication: configure netlogin dot1x; RADIUS server configured with configure radius primary server <ip> ...; supplicants authenticate before the port is authorized.

  • MAC-based authentication (netlogin mac) authenticates devices by MAC against RADIUS; Web-based authentication (netlogin web) redirects users to a login page.

  • ACLs on EXOS are created with create access-list <name> ... and applied to VLANs or ports with configure access-list <name> [ports|vlan] ...; ACLs match on L2/L3/L4 fields.

  • DHCP snooping with enable dhcp snooping and trusted ports prevents rogue DHCP servers; dynamic ARP inspection (DAI) validates ARP packets against the DHCP snooping binding table.

  • IP source guard binds source IP/MAC to the DHCP snooping table, dropping spoofed source addresses on untrusted ports.

  • Management access security: restrict SSH/Telnet/SNMP to a management VLAN, apply ACLs, use configure snmpv3 for encrypted SNMPv3, and disable unused services.

  • RADIUS/TACACS+ AAA: configure aaa radius primary server <ip> and configure aaa primary authentication radius; TACACS+ is commonly used for per-command authorization.

Quick reference

Monitoring, Troubleshooting, and Operations

  • show ports <portlist> statistics displays per-port counters; clear ports <portlist> counters resets them. show ports <portlist> info detail shows link state, speed, and flow control.

  • show log displays the system log; configure log target <target> sets log destinations (memory-buffer, console, syslog server). Severity levels range from emergency to debug.

  • show tech-support collects a diagnostic bundle for TAC; show diagnostics displays hardware health (temperature, fans, power supplies).

  • sFlow/NetFlow: enable sflow and configure sflow collector <ip> export traffic samples; show sflow verifies configuration.

  • show version displays software image, boot image, and hardware; show switch shows slot/stack status; show slot shows module inventory.

  • Spanning tree troubleshooting: show stpd <name> ports shows roles/states; show stpd <name> bridge shows bridge priority and root. show lldp neighbors maps topology.

  • ping and traceroute are available from the EXOS CLI: ping <ip> {count <n>} and traceroute <ip>; show iparp verifies ARP resolution.

  • show configuration and show configuration <module> help audit running config; diff (where supported) compares saved vs running configuration.