FenestrationMasters flashcards
FenestrationMasters · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- NAFS Performance Class
- A designation in AAMA/WDMA/CSA 101/I.S.2/A440 that groups windows by intended use and minimum performance: R, LC, C, HC, and AW, from lowest to highest design pressure and water resistance.
- Performance Grade (PG)
- A number on a NAFS label expressing the product's design pressure in psf; PG 40 means the unit is rated for 40 psf design pressure and meets associated water and structural criteria.
- Safety glazing label
- A permanent, legible mark required by 16 CFR 1201 on glazing used in hazardous locations; it identifies the manufacturer and confirms the product passed the CPSC safety glazing test.
- Egress window opening
- An emergency escape opening in a sleeping room, typically requiring at least 5.7 sq ft net clear opening, 20 in. minimum width, 24 in. minimum height, and sill no more than 44 in. high.
- Casement window
- A window with a sash hinged on one vertical side and operated by a crank or lever; it swings outward and compresses against the frame seal, giving good air and water performance.
- Insulated glass unit
- Two or more glass lites separated by a spacer and sealed at the perimeter, with a desiccant-filled spacer and dry gas or air in the cavity to improve thermal performance.
- Warm-edge spacer
- A low-conductivity spacer made of polymer, foam, or hybrid materials that reduces heat flow at the glass edge compared with aluminum, raising edge temperature and reducing condensation.
- Thermal break
- A low-conductivity separator, such as polyamide or polyurethane, placed between interior and exterior aluminum frame members to reduce conducted heat flow through the frame.
- Fully tempered glass
- Glass heat-treated to at least 10,000 psi surface compression; it is stronger than annealed glass and breaks into small dice-like fragments, qualifying it as safety glazing.
- Laminated glass
- Two or more glass lites bonded by a PVB, SGP, or EVA interlayer; the interlayer holds fragments in place after breakage and adds safety, security, and acoustic benefits.
- Solar heat gain coefficient
- The fraction of incident solar radiation admitted through a fenestration system as heat, including directly transmitted and absorbed-then-inward-released energy; it ranges from 0 to 1.
- Low-E coating
- A thin metallic or metal-oxide film on glass that reflects long-wave infrared radiation, reducing radiative heat transfer; soft-coat is sputtered and hard-coat is pyrolytic.
- Design pressure
- The wind pressure a fenestration product must resist, calculated from ASCE 7 wind parameters; NAFS structural testing applies 1.5 times this pressure to verify performance.
- Mullion
- A vertical or horizontal framing member that separates and supports individual glazed units; structural mullions must be engineered for the tributary wind area they carry.
- Setting blocks
- Small pads, usually EPDM or silicone, placed under the glass at the quarter points of the lite to carry dead load and keep glass from bearing directly on the frame.
- Structural silicone glazing
- An assembly where silicone structural sealant transfers wind load from glass to frame; design follows ASTM C1401 and often includes a secondary mechanical retention system.
- Whole-window U-factor
- The area-weighted heat transfer coefficient of the complete assembly, combining center-of-glass, edge-of-glass, and frame performance; lower values indicate better thermal insulation.
- Condensation resistance
- A relative index, such as NFRC CR or AAMA CRF, indicating how well a fenestration product resists interior condensation; higher values mean warmer interior surfaces and less condensation.
- Light-to-solar-gain ratio
- The ratio of visible light transmittance to solar heat gain coefficient; a higher ratio means more daylight per unit of admitted solar heat, desirable in cooling-dominated climates.
- Argon gas fill
- A dense, inert, colorless gas used in IGU cavities; it reduces conduction and convection compared with air, improving U-factor, and is most effective in moderate cavity widths.
- Sill pan flashing
- A sloped, watertight flashing installed beneath a window sill and integrated with the weather-resistive barrier to collect and drain water that penetrates the assembly.
- Weep hole
- A small opening at the sill or glazing pocket that allows water to drain to the exterior; it must remain unobstructed and be located at the lowest point of the sill.
- Pressure-equalized rainscreen
- A wall design with a vented air cavity and compartmentalization that equalizes pressure across the cladding, reducing wind-driven water penetration through joints and openings.
- Vapor retarder placement
- The climate-dependent location of a low-perm material in a wall; cold climates place it on the warm interior side, while hot-humid climates require drying potential to avoid trapped moisture.
- Air leakage rate
- The volume of air passing through a fenestration product per unit area at a specified pressure differential, typically tested per ASTM E283 and rated under NFRC 400.
- Sound Transmission Class
- A single-number rating from ASTM E413 derived from ASTM E90 laboratory measurements, expressing how well an assembly reduces airborne sound between interior spaces.
- Outdoor-Indoor Transmission Class
- A single-number rating from ASTM E1332 that weights low-frequency sound such as traffic and aircraft, used to rate exterior façade assemblies and generally lower than STC.
- Acoustic interlayer
- A specially formulated PVB or similar film in laminated glass that damps vibration and improves sound reduction, especially at coincidence frequencies, compared with monolithic glass.
- Backer rod
- A flexible foam rod placed in a joint before sealant to control sealant depth, support the sealant, and allow proper joint movement; it also helps prevent three-sided adhesion.
- Bond breaker
- A material or tape applied to the joint bottom so sealant adheres only to the two faces, allowing movement and preventing three-sided adhesion that can cause sealant failure.
- Shingle-lap flashing
- An installation sequence in which upper water-shedding layers overlap lower ones, so water flows outward and downward over the weather-resistive barrier and flashing without entering the assembly.
- NFRC Certified Products Directory
- The official listing of fenestration products certified under the NFRC program, showing U-factor, SHGC, VLT, and air leakage ratings that can be verified against the product label.