Fire Inspector study materials
Fire Inspector study resources

Fire Inspector case studies

Fire Inspector · Put your knowledge to work in context.

The ICC Fire Inspector certification is a professional credential offered by the International Code Council (ICC) for individuals who inspect buildings and properties for fire code compliance. It is intended for fire inspectors, code enforcement officers, and others responsible for enforcing fire prevention codes. The Fire Inspector case studies are 5 cases and about 4,330 words.

1

The Tavern at 10:40 p.m.: Occupant Load and a Second Exit That Does Not Exist

The complaint came in as a noise issue, but the inspector arrives at a 6,400 sq ft tavern at 10:40 p.m. on a Saturday to find a line of patrons still waiting outside.

921 words, about 5 min
2

Current Tag, Invalid Protection: The Unpermitted Charcoal Charbroiler

A 120-seat restaurant in a strip mall has generated three smoke complaints in two months, so the inspector arrives during the dinner rush. Under the Type I hood are a gas range and a deep fryer that appear on the original 2016 plans, plus a charcoal charbroiler the owner added eight months ago without a permit.

686 words, about 3 min
3

The Acceptance Test That Was Not an Acceptance Test

Final inspection of a new four-story, 120-room hotel (Group R-1) is set for a Friday, with the certificate of occupancy scheduled for the following Wednesday. The fire alarm acceptance test is the last item.

874 words, about 4 min
4

Nine Days With the Control Valve Closed

A 180,000 sq ft single-story warehouse (Group S-1) with 140 employees on two shifts is being visited on a routine annual sprinkler inspection follow-up. In the riser room the inspector finds the 6-inch OS&Y control valve fully closed and a handwritten tag reading 'backflow repair 6/2 - do not open.' The valve tamper switch has been placed in bypass at the panel, and that supervisory signal has been silenced for nine days.

888 words, about 4 min
5

205 Gallons, No Cabinet, and a Pilot Light 18 Inches Off the Floor

An auto body shop occupying a 4,800 sq ft single-story, unsprinklered building holds an operational permit for 'not more than 60 gallons of Class IB flammable liquids in approved cabinets.' On a complaint inspection the inspector finds three 55-gallon drums of lacquer thinner in a 200 sq ft mixing room, two of them fitted with rotary drum pumps, plus eight 5-gallon pails of reducer - about 205 gallons in total. The mixing room is separated from the shop by a wood-stud wall with a hollow-core door held open by a wedge.

961 words, about 5 min