Firefighter Certification flashcards
Firefighter Certification · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Two-in/two-out rule
- At least two firefighters enter an IDLH atmosphere together while two others remain outside ready to rescue, unless a known life hazard justifies immediate entry.
- LUNAR mayday report
- A radio format for a firefighter mayday that gives Location, Unit, Name, Air supply remaining, and Resources needed so command can act quickly.
- PASS device
- A Personal Alert Safety System sounds a loud alarm when a firefighter is motionless for about 30 seconds or manually activates it, helping rescuers locate a downed member.
- Fire tetrahedron components
- The four elements required for combustion are fuel, oxygen, heat, and the chemical chain reaction; removing any one of them extinguishes the fire.
- Flashover
- The transition to total surface involvement within a compartment, with ceiling temperatures near 1,100 degrees F and simultaneous ignition of all combustible contents.
- Backdraft conditions
- A smoke explosion caused by sudden oxygen introduction into an oxygen-starved, high-heat space; indicators include pressurized smoke and air drawn inward at openings.
- Type V construction
- Wood-frame construction with combustible walls and structural members, common in residential occupancies and prone to rapid fire spread and early collapse.
- Class I standpipe system
- A standpipe with 2.5-inch connections intended for fire department use, typically installed in tall buildings to supply hose lines on upper floors.
- Dry pipe sprinkler system
- A system whose pipes normally hold pressurized air so water enters only after a sprinkler activates and the air escapes, protecting unheated spaces from freezing.
- SCBA low-air alarm
- An audible and visual warning that activates when the cylinder reaches roughly 25 percent of capacity, signaling the wearer to exit the hazard area.
- SCBA cylinder hydrostatic test
- Self-contained breathing apparatus cylinders are requalified by hydrostatic testing every five years to verify they can still safely hold their rated pressure.
- NFPA 1981
- The standard covering open-circuit self-contained breathing apparatus for emergency services, specifying performance, testing, and certification requirements for SCBA.
- Vehicle extrication stabilization
- Securing a vehicle with cribbing, chocks, and struts before patient access, preventing movement while tools and rescuers work on the vehicle.
- Trench spoil pile placement
- Excavated soil must be placed at least two feet back from the trench edge to reduce the likelihood of the lip collapsing onto rescuers below.
- Airbag capacitor discharge wait
- After the 12-volt battery is disconnected, responders wait several minutes for backup capacitors to discharge before cutting near undeployed airbags.
- Positive pressure ventilation setup
- A PPV fan is placed at the inlet blowing inward, and the exhaust opening should be roughly one and a half to three times the fan area.
- Vertical ventilation purpose
- Releasing hot smoke and gases through a roof opening improves interior visibility and temperature, but only after a charged hoseline is ready.
- Through-the-lock forcible entry
- Removing a lock cylinder and using a key tool to operate the internal mechanism, commonly used on commercial doors that resist conventional prying.
- Ground ladder angle
- Place ground ladders at about 75 degrees from horizontal, with the base one-quarter of the working length away from the building.
- Ladder above roofline
- Extension ladders should extend three to five rungs above a roof edge, or about two rungs above a window sill being used for entry.
- Primary search
- A rapid, systematic search for life begun immediately on arrival, often before fire control, covering the most threatened and likely occupied areas first.
- Handline nozzle pressure
- Standard fog and smooth-bore handlines operate at 100 psi nozzle pressure to deliver their designed flow without excessive nozzle reaction.
- Hose friction loss formula
- Friction loss equals the hose coefficient times the flow in hundreds of gallons per minute squared times the hose length in hundreds of feet.
- Drafting lift limit
- Drafting is practical only about 20 to 25 feet above the water surface, because atmospheric pressure cannot lift water higher at sea level.
- V-pattern fire indicator
- Charring that forms a V shape on a wall points upward from the origin, with the apex marking the lowest point of the burning region.
- Overhaul objective
- Opening concealed spaces and wetting hot spots after fire control to find hidden fire and prevent rekindle before the scene is released.
- Fire cause classifications
- Causes are classified as accidental, natural, incendiary, or undetermined; undetermined applies when evidence is insufficient to assign a definite cause.
- Initial isolation distance
- For an unknown hazardous materials release, responders establish initial isolation of at least 150 feet in all directions and approach from upwind.
- ERG color-coded sections
- Yellow pages list chemicals by name, blue pages list them by identification number, orange pages give response guides, and green pages give isolation distances.
- DOT hazard class 3
- Flammable and combustible liquids such as gasoline and alcohol, identified by red placards or labels bearing a flame symbol.
- Span of control
- One supervisor can effectively manage roughly three to seven subordinates, with five considered optimal in most incident command structures.
- EDITH fire safety message
- Exit Drills In The Home: occupants should identify two ways out of every room and practice an escape plan with a meeting place.