Alarm System Contractor I
State-certified contractor authorized to install and service burglar alarm, fire alarm, CCTV, access control, and intercom systems, including low-voltage wiring incident to those systems.
Alarm System Contractor II
State-certified contractor authorized to install burglar alarm, CCTV, access control, and intercom systems; fire alarm system work is expressly excluded from this category.
Registered contractor limit
A registered contractor may perform contracting only within the jurisdiction that issued the certificate of competency; work outside that jurisdiction requires state certification.
Qualifying agent
An individual who holds the required certificate and directly supervises the contracting business; the qualifier's license number must appear on contracts, permits, and advertising.
Fire alarm permit
A separate permit issued by the local fire official for fire alarm system installation, distinct from the building permit, with acceptance testing required before final approval.
Unlicensed contracting penalty
A first offense of contracting without a required license is a first-degree misdemeanor; a subsequent offense is a third-degree felony under Florida law.
Continuing education requirement
Certificate holders must complete 14 hours of continuing education per biennium, including 1 hour each on workplace safety, business practices, and workers' compensation.
Claim of lien deadline
Under Chapter 713, F.S., a contractor must record a claim of lien within 90 days of last furnishing labor or materials and file suit to foreclose within one year.
Workers' compensation threshold
Florida construction employers with four or more employees must carry workers' compensation coverage; noncompliance can result in a state stop-work order.
Three-day cancellation right
Certain residential contracts must disclose the buyer's right to cancel within three days; the notice must appear in the written contract.
DBPR disciplinary grounds
Grounds include fraud, incompetence, abandoning a project, failing to obtain permits, and aiding unlicensed contracting under s. 489.533, F.S.
Rough-in inspection
An inspection of concealed wiring and devices performed before covering work; concealing work before the required inspection is a code violation under the FBC.
Threshold building
A building classified under s. 553.71, F.S. based on height, occupancy, and area that requires special inspectors and additional design professional involvement.
Listed and labeled
Products must be evaluated by an approved agency and bear a label where the Florida Building Code requires listing, such as fire alarm devices and power supplies.
Existing Building Code volume
The FBC volume that governs repairs, alterations, additions, and changes of occupancy in existing structures, separate from the new-construction provisions.
Local code amendment process
Local amendments to the Florida Building Code must be adopted through the state review process; jurisdictions may not adopt conflicting technical amendments without approval.
Fire official acceptance test
The fire code official has authority over fire alarm acceptance testing; NFPA 72 compliance must be demonstrated before the system is approved for use.
Notice of commencement
A recorded document under Chapter 713, F.S. that establishes the start of construction and affects lien priority and the owner's payment obligations.
Class 2 circuit
A power-limited circuit defined in NEC Article 725 with limited energy; it must be separated from power conductors unless listed for combined use.
FPLP cable
Plenum-rated fire alarm cable listed for use in environmental air spaces, required where cable runs through air-handling plenums.
FPLR cable
Riser-rated fire alarm cable listed for vertical runs between floors in a building; not suitable for plenum spaces unless also plenum-rated.
Smoke detector spacing
On smooth ceilings, smoke detectors are spaced at 30 feet maximum, with the first detector located within 15 feet of the wall per NFPA 72.
Fire alarm battery calculation
Secondary power for commercial fire alarm systems must provide 24 hours of standby followed by 5 minutes of alarm signaling under NFPA 72.
NEC Article 760
The National Electrical Code article governing fire alarm systems, including wiring methods, cable types, and power-limited circuit requirements.
NEC Article 725
The article defining Class 1, Class 2, and Class 3 remote-control and signaling circuits, including power limitations and separation requirements.
ANSI/TIA-607
The standard for telecommunications bonding and grounding infrastructure, requiring connection to the building grounding electrode system.
Notification appliance circuit
A circuit supplying audible and visible fire alarm devices; it must meet candela ratings and audibility requirements such as 15 dBA above ambient.
Class 1 wiring method
A wiring method used when power exceeds Class 2 or Class 3 limits; the circuit must be installed using Chapter 3 wiring methods.
Access control power supply
A listed power source for access control systems; it must not exceed Class 2 power limits unless installed using Class 1 wiring methods.
CCTV system scope
Closed-circuit television and video surveillance wiring falls within Alarm System Contractor I and II scope, including low-voltage cabling incident to the system.
Employee exemption
Employees of a licensed contractor working under the contractor's supervision are exempt from individual licensure requirements for that work.
Florida Building Code adoption
The Florida Building Code is adopted under Chapter 553, F.S., and applies to new construction, additions, alterations, repairs, and changes of occupancy.